METRON Nano, Standar, Duo User Manual

ENGLISH
EV CHARGING STATION
USER MANUAL
About
Information about charging stations and the
latest version of this document is available at
To contact METRON, call +386 51 320 538
or write us an e-mail on info@euato.si
ILLUSTRATIONS The illustrations provided in this document are for demonstration purposes only. Depending on charging station options and market region, the information may appear slightly different.
PRODUCT SPECIFICATIONS All specifications and descriptions contained in this document are verified to be accurate at the time of printing. However, because continuous improvement is a goal at METRON, we reserve the right to make product modifications at any time. To communicate any inaccuracies or omissions in this document, please send an email to: info@eauto.si
2018 METRON, d.o.o. All information in this document is subject to copyright and other intellectual property rights of METRON, d.o.o. and its licensors. This material may not be modified, reproduced or copied, in whole or in part, with­out the prior written permission of Metron, d.o.o. and its licensors. Additional information is available upon request.
Contents
About………………………………………………..2
General……………………………………………………….2 Safety…………………………………………………………..2
Intended use…………………………………………………………….2 Qualification of personnel……………………………………….3
Product description……………………………………3
Optional equipment…………………………………………………4 Identification plate……………………………………………………4 Exterior And Interior View……………………………………….5 General Data……………………………………………………………..6 Maximum Cable Cross-Section At Terminals………………………………………7 Ambient Conditions………………………………………………….7
Installation…………………………………………8
Choice Of Location…………………………………………………..8 Unpacking…………………………………………………………………9 Opening The Charging Station……………………………….9 Minimum Distances…………………………………………………10 Installing The Charger Station On The Wall………………………………………………………………11
Electrical connection……………………..12
Voltage Supply / Supply Network Connection………………………………….12 Safeguarding And Personal Protection…………………12 Connecting The Supply Line………………………………….13
Operation………………………………………..14
Dynamic Power Control…………………………………………14 How To Set The Charging Station Part 1……………………15 1st Group – Current Setting…………………………………….15 2nd Group – Main Household Fuse Type………………..16 3rd Group – On-board Charger Response Time…………………………………………16 How To Set The Charging Station Part 2…………………..16 Example 1…………………………………………………………………17 Example 2………………………………………………………………..18 Re-activating The Residual Current Circuit Breaker And Circuit Breaker…………………………..19 Charging the vehicle……………………………………………….19 Mode 3 Charging……………………………………………………20 Terminating The Charging Process……………………….20 Status LED………………………………………………………………..20
Maintenance……………………………………21
Maintenance Plan……………………………………………………21
Troubleshooting…………………………….22
Disassembly, Storage and Disposal…………………………………..23
Disassembly…………………………………………………………….23 Storage…………………………………………………………………….23 Disposal……………………………………………………………………23
Warranty…………………………………………24
Limited Warranty…………………………………………………….24 Returning Devices…………………………………………………..24
About
2
EV Charging station user manual
General
This manual is an important aid for ensuring the fault-free and safe operation of the device. The specifi­cations in this manual apply only to the device stated in the product description. Read this manual before setting up the device.
Using this manual will help you to:
• avoid any risks for the user
• become acquainted with the device
• achieve optimum functioning
• promptly detect and rectify faults
• avoid any malfunctions due to improper installation
• cut down on repair costs and reduce the number of downtimes
• improve the reliability and increase the service life of the system
• avoid causing harm to the environment
These instructions are an important part of the product and must be retained for future reference. METRON accepts no liability for any damage resulting from non observance of the information in this manual.
Safety
The device has been designed using state-of-the-art technology and is safe to operate.
Nevertheless, there may be residual risks associated with the device under the following circumstances:
• the device is not used as intended
• non-compliance with the safety information given in this manual
• the device is damaged
• the device is not maintained properly
• the device is modified or converted improperly
• the maintenance work specified in this manual is not carried out in due time
Warning: Risk of death resulting from non-compliance with documentation! Any person authorized to work on the system must have read and understood this manual, in particular the “Safety” chapter.
The electrical installation, initial operation and servicing of the device may only be performed by quali­fied electricians who have been authorized by the operator.
Intended Use
The device may be used for the purpose described in “Product Description” on page 3 and in conjunc­tion with the supplied and approved components. Any use exceeding the aforementioned shall be deemed unintended. METRON assumes no liability for damage resulting from non-intended use. Intend­ed use also includes:
• compliance with all the information in this manual;
• carrying out of servicing tasks according to schedule.
The device may present hazards, if not used as intended.
About
3
EV Charging station user manual
Qualification Of Personnel
The electrical installation, setup and maintenance of the device may only be performed by qualified elec­tricians, which have received authorization from the system operator to perform such tasks. Such persons must have read and understood the operating manual and must comply with the information therein.
Requirements of qualified electricians:
• knowledge of general and special safety and accident prevention guidelines;
• knowledge of relevant electrical guidelines (e.g. DIN VDE 0100 section 600 DIN VDE 0100722), as
well as valid national regulations;
• the ability to recognize risks and avoid possible dangers.
Product Description
METRON range of charging stations (Nano, Standard and Duo) is unique for its robustness and durability with close to zero maintenance. It is designed to charge electric vehicles and is supplied either with
a type 2 socket or on cable Type 2/Type 1 plug with various charging power capabilities. Nano charging station also has an option of advanced dynamic power control.
The METRON charging station is meant to be used in private and semi-public areas, such as company car parks, depots or private land.
The charging station is used exclusively for charging electrically powered vehicles.
• Mode 3 charging according to IEC 61851-1:2010.
• Plugs and sockets according to IEC 62196.
The charging station is operated as a stand-alone solution without connection to a master control sys­tem. The charging station is intended solely for fixed installation.
Features:
• Status information through LED
• METRON charging station communication and control unit EVSE
• Push button for setting current
• Steel made enclosure
• Wired ready for connection
About
4
EV Charging station user manual
Optional Equipment
Depending on the version, the charging station is equipped with one of the following connector systems:
1. Charging socket Type 2 for Mode 3 charging.
2. Permanently connected charging cable with charging connector Type 2.
3. Permanently connected charging cable with charging connector Type 1.
Identification Plate
1. Manufacturer
2. Type
3. Grid connection and current setting
4. Temperature operating range
5. Country of origin
6. Web page
7. Serial number
8. Protection class
9. Year of production
10. Certification mark
About
5
EV Charging station user manual
Exterior And Interior View
1. Lock
2. LED light
3. Push button
4. Socket
5. kWh counter
6. Charging cable fuse
7. Charge control fuse
8. RCCB
9. Circuit braker CB
10. CP terminal
11. Terminal earth
12. charge controler
About
6
EV Charging station user manual
General Data
Nano Standar Duo
Charging station plug/ socket type
Type 2 / Type 1 (IEC 62196 / SAE J1772) female plug or type 2 charging socket
Type 2 (IEC 62196) female plug or charging socket
Type 2 (IEC 62196) female plug or charging socket
Required power cable 3G2,5 mm2 for 3, 7 kW 5G2,5 mm2 for 11 kW
5G6 mm2 for 22 kW
2x5G2,5 mm2 for 11 kW 2x5G6 mm2 for 22 kW
3G6 mm2 for 7,4 kW 5G2,5 mm2 for 11 kW 3x16 A / 11 kW or 3x32 A
/ 22 kW*
Min: 2 sockets 1x16A and Max: 2 sockets 3x16A *
5G6 mm2 for 22 kW 2x5G2,5 mm2 for 11 kW 6/8/10/13/16 A or
6/8/10/13/16/20/25/32 A**
6/8/10/13/16 A**
2x5G6 mm2 for 22 kW 3,7 kW or 7,4 kW
(1-phase)
11 kW or 22 kW (3-phase)
11 kW (3-phase)
Max. charging current 16 A / 3,7 kW or 32 A /
7,4 kW *
3x16 A / 11 kW or 3x32 A / 22 kW*
Min: 2 sockets 1x16A and Max: 2 sockets 3x16A *
Possible charging cur­rent settings
6/8/10/13/16 A or From 155 V to 470 V
(3-phase) (50/60 Hz)
From 90 V to 270 V (1­phase) or from 155 V to 470 V (3-phase) (50/60 Hz)
6/8/10/13/16/20/25/32 A**
5m*** 5m*** 5m***
6/8/10/13/16 A or Yes Yes
6/8/10/13/16/20/25/32 A**
Yes Yes Yes
6/8/10/13/16 A** Optional Optional
Max. charging power 3,7 kW or 7,4 kW
(1-phase)
11 kW or 22 kW (3-phase)
11 kW (3-phase)
Rated Voltage 230 Vac 230 Vac/400 Vac 230 Vac/400 Vac
Operating voltage/fre­quency range
From 180 V to 270 V (50/60 Hz)
From 155 V to 470 V (3-phase) (50/60 Hz)
From 90 V to 270 V (1­phase) or from 155 V to 470 V (3-phase) (50/60 Hz)
Cable length (if ordered with plug and cable)
5m*** 5m*** 5m***
Circuit breaker Yes Yes Yes
Type A RCD protection Yes Yes Yes
Type B RCD protection Optional Optional Optional
UV resistance Yes (all parts) Yes (all parts) Yes (all parts)
Operating ambient air temperature range
From -30°C to +50°C From -30°C to +50°C From -30°C to +50°C
About
7
EV Charging station user manual
Nano Standar Duo
IP Rating IP54 IP54 IP54
Weight App 8-10 kg App 8-10 kg App 10-12 kg
Dynamic power control Optional No No
*Exact max charging power and configuration information can be found on the product information label, which is located on the right hand side of the charging station. **Charging current setting is based on the order and only customers that need max 32A/phase can set the charging current above 16 A. ***Cable length is based on the order.
Maximum Cable Cross-Section At Terminals
Power Rigid Flexible
3.7 kW 3 x 6 mm2 3 x 4 mm2
7.4 kW 3 x 10 mm2 3 x 6 mm2
11 kW 5 x 6 mm2 5 x 4 mm2
Ambient Conditions
Ambient temperature -25 to +40 °C
Average temperature over 24 hours < 35 °C
Storage temperature Altitude -25 to +40 °C
Altitude max. 2,000 meters above sea level
Relative humidity max. 95 % (non-condensing)
Loading...
+ 19 hidden pages