Installation & User Guide
Models:R1000-AAF / R1000-AAR / R1000-ADF
R1000-ADR / R1000-DDF / R1000-DDR
Radiance Series
R1000 Premise Service Platform:
R1000-AAF ____ 2-slot platform with AC/AC front-mounted power supplies
R1000-AAR ____ 2-slot platform with AC/AC rear-mounted power supplies
R1000-ADF ____ 2-slot platform with AC/DC front-mounted power supplies
R1000-ADR____ 2-slot platform with AC/DC rear-mounted power supplies
R1000-DDF ____ 2-slot platform with DC/DC front-mounted power supplies
R1000-DDR____ 2-slot platform with DC/DC rear-mounted power supplies
Accessories:
R1000-RM_____ 23-inch rack-mounting hardware
The following is a listing of additional products in the Metrobility Radiance series.
Refer to each product’s specific installation and user guide for operational
features.
R5000 Central Service Platform:
R5000-17HS ___17-slot 2U platform
Line Cards:
10Mbps100Mbps
Copper to coaxCopper to fiber
Copper to fiberFiber to fiber
RedundantRedundant
10/100MbpsAccess
Copper to copperGigabit
Copper to fiberFiber to fiber
Fiber to fiberCopper to fiber
SONETT1/E1
Fiber to fiberCopper to fiber
T3/E3
Copper to fiber
Management:
R502-M _______ Management card with dual Ethernet interfaces and
embedded WebBeacon management software
NetBeacon
This publication is protected by the copyright laws of the United States and other countries, with all
rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated,
transcribed, or transmitted, in any form, or by any means manual, electric, electronic, electromagnetic,
mechanical, chemical, optical or otherwise, without prior explicit written permission of Metrobility Optical
Systems, Inc.
R1000 T echnical Specifications ......................................................... 16
Product Safety, EMC and Compliance Statements ............................17
Warranty and Servicing ...................................................................... 18
Metrobility Optical Systems, the Metrobility Optical Systems logo, NetBeacon and WebBeacon are
trademarks of Metrobility Optical Systems, Inc. All others are trademarks of their respective owners.
The information contained in this document is assumed to be correct and current. The manufacturer is
not responsible for errors or omissions and reserves the right to change specifications at any time
without notice.
4
Overview
The Radiance R1000 Premise Service Platform is the demarcation point
between the service provider and the customer site. It is specifically designed to
address the needs of both service providers and enterprises wishing to attain the
maximum isolation and management between public and private networks.
Available with slots for two line cards, or one management card and one line
card, the R1000 provides two redundant, load-sharing power supplies to ensure
nonstop operation. Used with any combination of single-slot Radiance line
cards, the R1000 supports a wide range of IP/Ethernet interfaces at 10, 100, and
1000Mbps, as well as T1/E1, T3/E3, SONET OC-3/STM-1 and OC-12/STM-4,
and Ethernet and Fast Ethernet redundant data paths.
To increase reliability and reduce troubleshooting time, Metrobility offers
several management options. The SNMP management card collects a variety of
network data and link information including the unit’s voltage and temperature.
NetBeacon™ element and service provisioning management software provides
proactive management support including automatic e-mail notification. For webbased management of the R1000 Premise Service Platform using a standard web
browser, Metrobility provides the WebBeacon™ kernel embedded into the
management card.
Metrobility’s carrier class solutions provide seamless connectivity with all major
switch and router manufacturers and offer a flexible solution for fiber
connectivity while reducing costs and adding functionality.
The Radiance Premise Service Platform provides the following key features:
• Dual, load-sharing power supplies.
• 19" and 23" rackmounting options.
• No SNMP, IP stack or IP address required at the customer site.
• Optional management card for SNMP management using the NetBeacon
software or any SNMP application.
• Separate bus paths for management, data and power for more efficient
internal communications.
• Strict standards compliance ensuring compatibility with other vendors’
equipment for flexible connectivity.
Radiance R1000 Premise Service Platform 5
Related Documentation
Refer to the following documents for additional information on the Radiance
Premise Service Platform:
• Radiance 100Mbps Access Line Cards Installation & User Guide
• Radiance 10Mbps Single Interface Line Cards Installation & User
Guide
• Radiance 100Mbps Single Interface Line Cards Installation & User
Guide
• Radiance 10Mbps Redundant Interface Line Cards Installation & User
Guide
• Radiance 100Mbps Redundant Interface Line Cards Installation &
User Guide
• Radiance 10/100Mbps Interface Line Cards Installation & User Guide
• Radiance Gigabit Single Interface Line Card Installation & User Guide
• Radiance SONET Single Interface Line Cards Installation & User
Guide
• Radiance T1/E1 Single Interface Line Cards Installation & User Guide
• Radiance T3/E3 Single Interface Line Cards Installation & User Guide
• Radiance Command Line Interface Reference Guide
• NetBeacon Element Management Software Installation & User Guide
• WebBeacon Management Software Installation & User Guide
6
Installation Guide
Follow the simple steps outlined in this section to install and start using the
Radiance R1000 Premise Service Platform.
Unpack the Platform and Accessories
Check that the following components have been included:
1
• Radiance R1000 Premise Service Platform
• Four (4) rubber feet
• 19" Rackmounting hardware (2 brackets and 8 screws)
• Power cord (one for each AC power supply)
• CD-ROM
The following items are available separately:
• NetBeacon software
• Line cards
• 23" Rackmounting hardware
Your order has been provided with the safest possible packaging, but
shipping damage does occasionally occur. Inspect it carefully. If you
discover any shipping damage, notify the carrier and follow their
instructions for damage and claims. Save the original shipping carton if
return or storage of the unit is necessary.
Mount the Platform
The R1000 is intended for use in office and industrial environments
2
either as a standalone unit or installed in an equipment rack.
Use the 6-32 self-tapping screws included with the platform to secure
the mounting brackets to the unit.
M
M
FX
LBK
DIS
LK
X
T
II
x
LBK
DIS
RX
100 BASE
PWRFDMAN
RX
LK
2
Radiance R1000 Premise Service Platform 7
You will need four (4) additional screws (not included with the R1000)
to mount the platform in the rack.
M
M
FX
LBK
DIS
LK
X
T
II
x
LBK
DIS
RX
100 BASE
PWRFDMAN
RX
LK
2
Make sure that the mounting of the R1000 does not create a hazardous
condition due to an unbalanced load. Consider the overall loading of
the branch circuit before installing any equipment into the rack.
Reliable grounding must be maintained in the rack system. This unit is
intended to be connected to earth ground.
Caution: The platform can become overheated in an enclosed equip-
ment rack or multi-rack assembly. When installing the
R1000, make sure that the exhaust fans on the left side of the
unit are not blocked—improper venting of the exhaust fans
can cause the unit to overheat.
When used as a standalone unit, attach the four (4) rubber feet onto the
stamped squares on the bottom of the R1000. The unit must be located
within six (6) feet of the AC or DC power source being used and placed
as far away as possible from electrical noise generating equipment such
as copiers, electrostatic printers and other motorized equipment. If
exposed twisted-pair wiring is used nearby, the wiring should be routed
as far away as possible from power cords and data cables to minimize
interference. Do not place any equipment on top of the R1000.
8 Installation Guide
3
4
Connect to the Network
Connecting the Line Cards
To connect the individual line cards to the network, refer to their
corresponding installation and user guides.
Connecting the Management Line Card
If a management line card is installed in your platform, follow the
procedure below to connect to the network. The management line card
supports 10Base-T Ethernet.
• Using a standard Category 3 or 5 UTP cable, connect the line card to
your network. Although the Ethernet port(s) can be configured for
either full or half duplex, half duplex is recommended. Refer to the
Command Line Interface Reference Guide for a detailed description
of configuration commands.
• Using the supplied null-modem console cable, connect the male DB9 port on the management card to the serial port on your PC.
Attach the Grounding Lug (DC models only)
On the back panel, the R1000 provides two horizontal grounding points
where a grounding lug must be installed. Use a Panduit® copper,
standard barrel, two-hole lug (part number LCD8-10A-L) or its
equivalent. Use two 10-32 screws to fasten the lug to the platform. Use
a No. 8 AWG copper wire to connect the lug to the grounding point at
your site.
DC PWR
B
I.T.E.
C
US
E116552
LISTED
CAUTION
RISK OF ELECTRIC
SHOCK, DO NOT OPEN
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
DISCONNECT ALL POWER SOURCES BEFORE SERVICING
DC PWR
A
DC IN
48V DC
1.3A
Radiance R1000 Premise Service Platform 9
5
Apply Power to the Platform
Depending on the model, power connections are located on the front or
rear of the R1000. When lit, the power (PWR) LEDs indicate that their
corresponding power supplies are connected to an active power source
and providing power to the platform’s backplane. Because the power
supplies are load-sharing, both PWR LEDs are lit simultaneously.
DC Power Supply Connections
IMPORTANT: • For installation in a restricted access location only.
• A readily accessible disconnect device must be
incorporated in the building installation wiring.
• Turn off the DC voltage source before beginning.
• Connect the wire leads to the R1000 before applying
power.
For DC connections, follow these guidelines:
• Remove the terminal block safety cover.
• Connect the wire leads from the voltage source to the appropriate
terminal and tighten the screws. If your unit has two DC connections,
make sure each power supply is connected to a separate power
source.
• Replace the terminal block safety cover.
• Verify proper connection and operation using the PWR LED.
IMPORTANT: The terminal block safety cover must be installed when
power is present to prevent burn or energy hazards.
Caution: The center terminal connector provides grounding for the
R1000 and should be maintained. Particular attention should
be given to power supply connections other than direct
connections to the branch circuit (e.g. use of power strips).
10 Installation Guide
AC Power Supply Connections
For AC connections, follow these guidelines:
• Set the ON/OFF switch to the OFF (O) position.
• Connect the power cord to the power supply receptacle on the
R1000. If your platform has two AC connections, make sure each
power supply is connected to a separate power source.
• Set the ON/OFF switch to the ON ( | ) position.
• Verify proper connection and operation using the PWR LED.
Radiance R1000 Premise Service Platform 11
12 Installation Guide
User Guide
This section contains more information regarding the Radiance R1000
Premise Service Platform.
Management Line Card
The management card is the SNMP agent for the R1000. Connected via the
backplane to the line cards in the R1000, the management card reports individual board status to Metrobility’s NetBeacon software or any SNMP application. Thus, the network administrator receives immediate information on network operations via a PC. Metrobility also provides the WebBeacon kernel, embedded into the management card, for Web-based management via the Internet
using browsers such as Netscape® Navigator® or Microsoft® Internet Explorer.
Refer to the Command Line Interface Reference Guide, NetBeacon Element
Management Software Installation & User’s Guide or WebBeacon Management Software Installation & User’s Guide for detailed software commands.
Line Cards
Metrobility’s line cards deliver carrier-class media, speed and distance solutions
to address the needs of today’s telecommunications networks. An extensive line
of plug-and-play, hot-swappable cards support IP/Ethernet interfaces at 10, 100,
1000Mbps, T1/E1, T3/E3, SONET OC-3/STM-1 and OC-12/STM-4. For
mission-critical applications, Metrobility’s Ethernet and Fast Ethernet redundant
line cards feature network-on-demand accessibility, reliability and enhanced
security.
Maximum segment lengths are supported on either side of the platform, and all
signal activity is reliably propagated from one cable to the other assuring
accurate data flow across the network.
Refer to the each line card’s specific installation and user guide for additional
product information.
Radiance R1000 Premise Service Platform 13
Operating Features of the Load-Sharing Power Supplies
The R1000 Premise Service Platform is shipped with two 12V internal fixed
power supplies. Depending on the model, these load-sharing power supplies are
designed for AC and/or DC power sources.
The two power supplies are designed to operate in tandem and share the load. If
the power source to one of the supplies fails, the other power supply automatically provides the entire power load to the platform. This setup provides both
the platform and the network with uninterrupted service. It also decreases the
demand placed upon an individual power supply, thus prolonging its life.
When the power (PWR) LED is lit, it indicates that its corresponding power
supply is connected to an active power source and delivering power to the
platform’s backplane. Both PWR LEDs are lit simultaneously when both power
supplies are sharing the load.
Important: Refer to the text on the front or rear panel for voltage/current
ratings. Reliable grounding of rackmount equipment must be maintained. Give
particular attention to power supply connections other than direct connections
to the branch circuit (e.g., use of power strips).
AC Power Supply Connections
Each AC power supply includes a standard North American three-pin cord
which is UL (USA), CSA or CUL (Canada) listed or approved. For installation
in regions outside North America, replace the power cord with a cord approved
by appropriate safety agencies. Any cord must have a CEE-22 standard V
female connector on one end and meet IEC 320-030 specifications. European
power cords must be harmonized and designated with a HAR marking on the
outside of the cord jacket to comply with the CENELEC Harmonized Document
HD-21.
When making power connections, connect the power cord to the input jack
before making the IEC 320 connection to the outlet or appropriate voltage
source. If your unit is equipped with two AC power supplies, be sure to connect
the individual power cords to separate power sources.
Operating Temperature____________________________________ 0° to 50° C
Storage Temperature____________________________________ -25° to 70° C
Relative Humidity _________________________ 5% to 95% non-condensing
Physical Case _________________________Fully enclosed metal construction
Dimensions ________________________________ 10.0"L x 17.0"W x 1.72"H
_______________________________ 25.4 cm x 43.2 cm x 4.4 cm
Weight_______________________________________________ 9.5 lb, 4.3 kg
Regulatory
Compliance_________________________________IEEE 802.3 (ISO 8802-3):
This equipment complies with the following requirements:
• UL/cUL
•CE
• EN60950 (safety)
• FCC Part 15, Class A
• EN55022 Class A (emissions)
• EN55024: 1998 (immunity)
• Class 1 Laser Product
• VCCI
• DOC Class A (emissions)
This product shall be handled, stored and disposed of in accordance with all
governing and applicable safety and environmental regulatory agency requirements.
The following FCC and Industry Canada compliance information is applicable
to North American customers only.
USA FCC Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses
and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Caution: Changes or modifications to this equipment not expressly approved by
the party responsible for compliance could void the user’s authority to operate
the equipment.
Canadian Radio Frequency Interference Statement
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du
Réglement sur le matériel brouilleur du Canada.
Radiance R1000 Premise Service Platform 17
Warranty and Servicing
Three-Year Warranty for the Radiance R1000 Pr emise Service Platform
Metrobility Optical Systems, Inc. warrants that every Radiance R1000 Premise
Service Platform will be free from defects in material and workmanship for a
period of THREE YEARS from the date of Metrobility shipment. This warranty
covers the original user only and is not transferable. Should the unit fail at any
time during this warranty period, Metrobility will, at its sole discretion, replace,
repair, or refund the purchase price of the product. This warranty is limited to
defects in workmanship and materials and does not cover damage from accident,
acts of God, neglect, contamination, misuse or abnormal conditions of operation
or handling, including overvoltage failures caused by use outside of the
product’s specified rating, or normal wear and tear of mechanical components.
To establish original ownership and provide date of purchase, complete and
return the registration card or register the product online at
www.metrobility.com. If product was not purchased directly from Metrobility,
please provide source, invoice number and date of purchase.
To return a defective product for warranty coverage, contact Metrobility
Customer Service for a return materials authorization (RMA) number. Send the
defective product postage and insurance prepaid to the address provided to you
by the Metrobility Technical Support Representative. Failure to properly protect
the product during shipping may void this warranty. The Metrobility RMA
number must be clearly on the outside of the carton to ensure its acceptance.
Metrobility will pay return transportation for product repaired or replaced inwarranty. Before making any repair not covered by the warranty, Metrobility
will estimate cost and obtain authorization, then invoice for repair and return
transportation. Metrobility reserves the right to charge for all testing and
shipping costs incurred, if test results determine that the unit is without defect.
This warranty constitutes the buyer’s sole remedy. No other warranties, such as
fitness for a particular purpose, are expressed or implied. Under no circumstances will Metrobility be liable for any damages incurred by the use of this
product including, but not limited to, lost profits, lost savings, and incidental or
consequential damages arising from the use of, or inability to use, this product.
Authorized resellers are not authorized to extend any other warranty on
Metrobility’s behalf.
18 User Guide
Caution: Danger of explosion if the battery on the management line card is
incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the
manufacturer’s instructions.
Radiance R1000 Premise Service Platform 19
Product Manuals
The most recent version of this manual is available online at
http://www.metrobility.com/support/manuals.htm
To obtain additional copies of this manual, contact your reseller, or call