Metrobility 2151-AD-01,2152-1A-01,2152-1D-01,2152-1F-01,2152-17-01,2152-1J-01,2152-1K-01,2152-1M-01,2152-1X-01,2152-1Y-01,2152-AA-01,2152-AD-01,2152-AF-01,2152-A7-01,2152-AJ-01,2152-AX-01,2152-AY-01,2152-DD-01,2152-DF-01,2152-D7-01,2152-DJ-01,2152-77-01,2152-JJ-01,2152-KM-01,2125-34-01,2125-37-01,2135-34-01 User guide

Lancast
Gigabit “twister”™ and
SONET “twister”
“twister”
2152
1000BASE-LX
BWDM
1000BASE-LX
SM MM
LINK
1000BASE-LX
SM
LINK
OC-12
TX RX
LINK LINK
TX RX
LINK
1000BASE-SX
1000BASE-TX
TX RX
“twister”
1000BASE-SX
MM
“twister”
LINK
“twister”
LINK
“twister”
OC-12
MMSM
1000BASE-LX
TX RX
PWR
LINK
2152
PWR
2152
PWR
2135
PWR
2152
1000BASE-TX
SM
LINK
PWR
LINK
“twister”
LINK
1000BASE-SX
SM MM
LINK LINK
1000BASE-SX
RX
TX
SM
RX
1000BASE-TX
“twister”
“twister”
MM
“twister”
OC-3
MM
LINK
1000BASE-LX
BWDM
1000BASE-LX
TX TXRX RX
1000BASE-LX
TX
SM
LINK LINK
OC-3
TX TX
LINK
LINK
RX
RX
2152
PWR
2152
PWR
2151
PWR
2125
PWR
Installation & User Guide
2151-AD-01 • 2152-1A-01 • 2152-1D-01 • 2152-1F-01 • 2152-17-01 2152-1J-01 • 2152-1K-01 • 2152-1M-01 • 2152-1X-01 • 2152-1Y-01 2152-AA-01 • 2152-AD-01 • 2152-AF-01 • 2152-A7-01 • 2152-AJ-01 2152-AX-01 • 2152-AY-01 • 2152-DD-01 • 2152-DF-01 • 2152-D7-01 2152-DJ-01 • 2152-77-01 • 2152-JJ-01 • 2152-KM-01 • 2125-34-01
2125-37-01 • 2135-34-01
Lancast Gigabit “twister” and SONET “twister”
Multimode-to-Singlemode Converter:
2125-34-01 ____ OC-3/STM-1 multimode SC to singlemode SC 2125-37-01 ____ OC-3/STM-1 multimode SC to singlemode SC (40km) 2135-34-01 ____ OC-12/STM-4 multimode SC to singlemode SC 2151-AD-01____1000Base-SX multimode SC to 1000Base-LX singlemode SC
Fiber-to-Fiber Repeater:
2152-AA-01 ____ 1000Base-SX multimode SC to 1000Base-SX multimode SC 2152-AD-01____1000Base-SX multimode SC to 1000Base-LX singlemode SC 2152-AF-01 ____ 1000Base-SX multimode SC to 1000Base-MR singlemode SC 2152-A7-01 ____ 1000Base-SX multimode SC to 1000Base-LH singlemode SC 2152-AJ-01 ____ 1000Base-SX multimode SC to 1000Base-EX singlemode SC 2152-AX-01 ____ 1000Base-SX multimode SC to 1000Base-LX singlemode SC 1550/
1310nm bidirectional wavelength division multiplexed (BWDM)
2152-AY-01 ____ 1000Base-SX multimode SC to 1000Base-LX singlemode SC
1310/1550nm BWDM 2152-DD-01____ 1000Base-LX singlemode SC to 1000Base-LX singlemode SC 2152-DF-01 ____ 1000Base-LX singlemode SC to 1000Base-MR singlemode SC 2152-D7-01 ____ 1000Base-LX singlemode SC to 1000Base-LH singlemode SC 2152-DJ-01 ____ 1000Base-LX singlemode SC to 1000Base-EX singlemode SC 2152-77-01 ____ 1000Base-LH singlemode SC to 1000Base-LH singlemode SC 2152-JJ-01 ____ 1000Base-EX singlemode SC to 1000Base-EX singlemode SC 2152-KM-01 ___ 1000Base-SX multimode LC to 1000Base-LX singlemode LC
Copper-to-Fiber Repeater:
2152-1A-01 ____ 1000Base-TX to 1000Base-SX multimode SC 2152-1D-01 ____ 1000Base-TX to 1000Base-LX singlemode SC 2152-1F-01 ____ 1000Base-TX to 1000Base-MR singlemode SC 2152-17-01 ____ 1000Base-TX to 1000Base-LH singlemode SC 2152-1J-01 ____1000Base-TX to 1000Base-EX singlemode SC 2152-1K-01 ____ 1000Base-TX to 1000Base-SX multimode LC 2152-1M-01____ 1000Base-TX to 1000Base-LX singlemode LC 2152-1X-01 ____ 1000Base-TX to 1000Base-LX singlemode SC 1550/1310nm BWDM 2152-1Y-01 ____ 1000Base-TX to 1000Base-LX singlemode SC 1310/1550nm BWDM
This publication is protected by the copyright laws of the United States and other countries, with all rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means manual, electric, electronic, electromagnetic, mechanical, chemical, optical or otherwise, without prior explicit written permission of Metrobility Optical Systems, Inc.
© 2001-2003 Metrobility Optical Systems, Inc. All rights reserved. Printed in USA.
Table of Contents
Lancast Gigabit “twister” and SONET “twister” Installation & User Guide
Introduction ................................................................................................................ 4
Overview ..................................................................................................................... 5
Installation Guide ....................................................................................................... 6
STEP 1: Unpack the “twister” and Accessories .......................................... 6
STEP 2: Choose an Appropriate Location .................................................. 6
STEP 3: Set the DIP Switches ..................................................................... 7
STEP 4: Connect to the Network ................................................................ 8
STEP 5: Apply Power.................................................................................. 9
User Guide ................................................................................................................ 11
LED Indicators .......................................................................................... 11
Link Loss Return (LLR)............................................................................ 12
Link Loss Carry Forward (LLCF)............................................................. 13
Copper Loss Carry Forward (CLCF) ........................................................ 14
Topology Solutions ................................................................................... 15
Technical Specifications ............................................................................ 15
Product Safety, EMC and Compliance Statements ................................... 18
Warranty and Servicing ............................................................................. 19
Lancast is a registered trademark; Metrobility Optical Systems, the Metrobility Optical Systems logo, and “twister” are trademarks of Metrobility Optical Systems, Inc.
The information contained in this document is assumed to be correct and current. The manufacturer is not responsible for errors or omissions and reserves the right to change specifications at any time without notice.
IntroductionThank you for choosing the Lancast “twister”.
The Lancast Gigabit “twister” and SONET “twister” represent the latest technology available for extending Gigabit Ethernet, OC-3/STM-1 and OC-12/STM-4 networks. Since Metrobility first developed “twister” media conversion, it has set the standard for providing affordable means of integrating mixed media networks. As LANs/ WANs grow and evolve, this technology provides an ideal solution for building effective migration strategies.
In addition to the standalone unit, the “twister” is available as an SNMP manageable module for the Lancast Intelligent 7500 chassis and the Radiance central or premise service platforms.
The information in this guide will help you to install and start using your “twister”.
4
Overview
The Lancast “twister” provides seamless integration between fiber optic
multimode and singlemode segments in Gigabit Ethernet, OC-3/STM-1 or OC-12/ STM-4 environments. It supports copper to fiber translation as well as wavelength conversion from 850nm to 1310 or 1550nm, and from 1310nm to 1550nm. With the Lancast “twister”, you can increase your network reach up to 70km on a single segment. For networks that require extended distance support, use the 2152-series repeaters. The repeaters recover incoming data and regenerate the signal, thus allowing multiple hops over any distance.
The Gigabit “twister” and SONET “twister” offer the following key features:
•A Link Loss Return (LLR) switch on each fiber optic port to aid in troubleshooting remote network connections.
Link Loss Carry Forward (LLCF) functionality on the fiber-to-fiber units or Copper Loss Carry Forward (CLCF) on the copper-to-fiber models. LLCF and CLCF work with LLR in diagnosing network connections.
Signal recovery that restores data integrity, enabling repetition over unlimited distances. (2152-series only)
Auto-sensing copper port that eliminates the need for crossover cables.
Full-duplex support.
Gigabit Ethernet (1Gbps), OC-3/STM-1 (155Mbps) or OC-12/STM-4 (622Mbps) support.
•A link LED on each port to indicate that the port is receiving idle link signals or a satisfactory level of light.
IEEE 802.3 Sec. 14 / IEEE 802.3z compliance (Gigabit “twister” only).
Universal desktop power supply (100-240V / 50-60Hz).
Data transmission over singlemode fiber up to 70km.
Numerous connectivity options, including bidirectional wavelength division multiplexed (BWDM) fiber.
*Actual distance should be calculated based on the actual link loss budget.
Gigabit “twister” and SONET “twister” 5
*
Installation Guide
Follow the simple steps outlined in this section of the guide to install and start using your Lancast “twister”.
Unpack the “twister” and Accessories
Check that the following components have been included:
Lancast “twister”
Power supply
Power cord
Four (4) rubber feet
Your order has been provided with the safest possible packaging, but shipping damage does occasionally occur. Inspect your order carefully. If you discover any shipping damage, notify your carrier and follow their instructions for damage and claims. Save the original shipping carton in case return or storage of the unit is necessary.
Choose an Appropriate Location
The “twister” is intended for use in either office or industrial environments.
2
The unit must be located within six (6) feet of the AC power source being used and placed as far away as possible from electrical noise generating equipment such as copiers, electrostatic printers and other motorized equipment. If exposed twisted-pair wiring is used nearby, the wiring should be routed as far away as possible from power cords and data cables to minimize interference.
The unit may be oriented in any manner which allows you to make physical connection to the power supply and leaves a minimum of six (6) inches of space for proper ventilation.
Set the DIP Switches
The Lancast “twister” includes a set of six DIP switches located on the
3
6 Installation Guide
back of the unit. (See figure below.) These switches are used to enable/ disable functions and are clearly marked. Unmarked switches are nonfunc­tional. LLR1 controls Link Loss Return on Port 1. LLR2 controls Link Loss Return on Port 2. LLCF sets Link Loss Carry Forward on the fiber­to-fiber repeaters (LLCF is nonfunctional on the fiber-to-fiber converters). CLCF sets Copper Loss Carry Forward on the copper-to-fiber repeaters.
Loading...
+ 14 hidden pages