Metro MPS-3111 User Manual

Metro™ Series
Mobile Computing Workstations
MPS-3111 Series
Sealed Lead Acid
Power Supply
L01-506 RevA
Copyright © 2013
InterMetro Industries Corporation
www.metro.com
THIS PAGE INTENTIONALLY LEFT BLANK
Notice:
InterMetro Industries Corporation reserves the right to make improvements or changes in the products described in this manual at any time without notice.
While reasonable efforts have been made in the preparation of this document to assure its accuracy, InterMetro Industries Corporation assumes no liability resulting from any errors or omissions in this document, or from the use of the information contained herein.
Copyright Notice:
This manual is copyrighted. All rights reserved. This manual may be printed for personal use only. This manual, whole or in part, may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form for distribution. This manual, whole or in part, may not be modified without prior consent, in writing, from InterMetro Industries Corporation.
Copyright © 2013 by InterMetro Industries Corporation, 651 North Washington Street, Wilkes-Barre, PA 18705, U.S.A.
Metro is a registered trademark of InterMetro Industries Corporation.
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Contact Information:
InterMetro Industries Corporation North Washington Street Wilkes-Barre, PA 18705 Phone: 1-800-992-1776 http://www.metro.com/support
FCC Information:
This device complies with FCC Rules, part 15. Operation is subject to the following conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference that may be received, including interference that may cause undesired
operation.
Notice: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user’s expense.
Warning: Changes or modifications to this device not expressly approved by InterMetro Industries Corporation could void the
user’s authority to operate this equipment.
Shielded cables must be used with this unit to ensure compliance with the FCC Class A limits.
Industry Canada:
This class A digital apparatus meets all requirements of the Canadian Interface Causing Equipment Regulations. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Regulatory Compliance
This system was tested and complies with UL 60601-1, CAN/CSA C22.22 No.601.1 and IEC/EN 60601-1-1 medical safety standards.
MetroTM MPS-3111 Series SLA Power Supply Operations Manual Supplement, Doc. No. L01-506
InterMetro Industries Corporation
3
Symbol Explanations
The product is CSA certified with respect to electrical shock, fire and mechanical hazards only in accordance with UL 60601-1, CAN/CSA C22.22 No.601.1 and IEC/EN 60601-1-1 as Type B Patient Care Medical Equipment suitable for use in patient vicinity.
Attention, consult accompanying documents
Important Safety Instructions
This document contains important safety and operating instructions for the MPS-3111 series Power Supply. Please read all instructions and cautionary markings before putting it into service on a Mobile Computing Workstation.
4 InterMetro Industries Corporation
Caution:
User maintenance consists of cleaning, periodic tightening of fasteners and the like. For safety purposes, any and all servicing other than the procedures detailed in the Maintenance section of this manual must be performed by qualified service personnel only. For all service items, please contact InterMetro Customer Service.
Caution:
Do not operate an MPS-3111 series Power Supply or associated Metro either has received a severe impact, been knocked over, fallen down stairs, or otherwise been physically damaged. Please have a qualified service person inspect both the Mobile Computing Workstation and the Power Supply for any performance or safety hazard prior to putting it back into service.
Caution:
Ensure that the AC power supply cord is located and secured so that it will not be stepped on, tripped over, or otherwise subjected to damage or stress. Please secure the AC power cord plug in the retaining clips provided on the Mobile Computing Workstation when it is unplugged from the AC outlet in order to prevent accidental tripping and physical damage to the cord plug or electrical insulation.
To prevent damage to any cords or connectors when disconnecting, always grasp and pull by the connector and not the cord.
Do not operate the Power Supply or Mobile Computing Workstation with damaged cords or connectors. Please replace the damaged component immediately. Contact InterMetro Customer Service for replacement parts and service.
Caution:
To reduce the risk of electric shock, unplug the Power Supply AC cord from an AC outlet and switch the ON/Extended Storage Switch to the Extended Storage (OFF) position before attempting any maintenance or cleaning. Turning off computers or disconnecting the AC power cord alone will not reduce the risk of electric shock because the Power Supply is internally powered by a battery.
Warning: Risk of Electric Shock
The AC power cord is the only means to disconnect the Power Supply and Metro Workstation from the AC power grid (mains). The ON/Extended Storage Switch on the Power Supply does not disconnect from main power.
On the other side, the Power Supply employs a Sealed Lead Acid (SLA) battery to provide mobile DC output power. Low voltage (10-16 VDC) DC power is available from the Power Supply even when the AC cord is disconnected from an AC outlet. To remove DC power, put the ON/Extended Storage Switch in the Extended Storage (OFF) position and unplug the Power Supply from the AC outlet.
DANGER: Risk of Explosion
The Mobile Computing Workstation and the Power Supply are not for use in hazardous (classified) locations. Do not use the Mobile Computing Workstation, nor recharge the Power Supply battery, in oxygen enriched areas; areas where flammable anesthetics are used or stored; or any other hazardous, classified location.
TM
Metro
MPS-3111 Series SLA Power Supply Operations Manual Supplement
TM
Series Mobile Computing Workstation if
TM
Series Mobile Computing
Electromagnetic Interference (EMI) Recommendations
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving device.
Increase the separation between the equipment.
Connect the equipment to an outlet on a circuit different from that to which the other device(s) are connected.
Consult the manufacturer or field service technician for help.
MetroTM MPS-3111 Series SLA Power Supply Operations Manual Supplement, Doc. No. L01-506
InterMetro Industries Corporation
5
Revision History
REV/
Issue
L01­506, RevA
Revision Description Date Approved
A Initial Release 6/4/2010 V. Bowman
1) As per Metro Standards this Operations Manual is assigned with new Commodity Code L01-506 with Initial Release as RevA with effective from 01/09/2013.
2) Previous nomenclature of this document is 402547 Rev A
01/09/2013 Paul Prickett
MPS 3111 SLA PS Operations Manual
3) Updated references in Page 9.
4) All above revisions remain valid in L01-506 RevA.
6
Metro
TM
MPS-3111 Series SLA Power Supply Operations Manual Supplement
InterMetro Industries Corporation
Table of Contents
References ...................................................................................................................... 9
Introduction ................................................................................................................... 10
Mobile Rechargeable Power Supply ....................................................................................................... 10
Power Supply Status ................................................................................................................................ 11
Remote Fuel Gauge Display .............................................................................................................................. 11
Features ................................................................................................................................................... 11
Equipment Classification ........................................................................................................................ 12
Disposal ................................................................................................................................................... 12
Getting Started .............................................................................................................. 13
Charging the Power Supply Battery ........................................................................................................ 13
Powering Up the MPS-3111 SLA Power Supply .................................................................................... 14
Operation ...................................................................................................................... 15
Power Supply Location on the MetroTM Series Mobile Computing Workstation ................................... 15
Powering Up the MPS-3111 SLA Power Supply .................................................................................... 16
Applying Power from AC Mains ....................................................................................................................... 16
Applying Mobile DC Power ............................................................................................................................... 16
Charging the Battery ............................................................................................................................................ 16
Remote Fuel Gauge ................................................................................................................................. 17
Power Supply Fuel Gauge ....................................................................................................................... 19
MPS-3111 Power Supply System Installation ............................................................... 22
Hardware Installation .............................................................................................................................. 22
Mounting the MPS-3111 Power Supply ........................................................................................................... 22
Removing the MPS-3111 Power Supply .......................................................................................................... 23
Maintenance and Storage ............................................................................................. 24
Cleaning .................................................................................................................................................. 24
Fuse Replacement ................................................................................................................................... 24
SLA Battery Replacement ....................................................................................................................... 25
Storage and Transport Conditions ........................................................................................................... 28
Troubleshooting ...................................................................................................................................... 29
MetroTM MPS-3111 Series SLA Power Supply Operations Manual Supplement, Doc. No. L01-506
InterMetro Industries Corporation
7
Technical Specifications ................................................................................................ 34
Contacting InterMetro Industries Corporation ................................................................ 36
InterMetro Industries Corporation Contact Information ......................................................................... 36
InterMetro Customer Service .................................................................................................................. 36
Repair ...................................................................................................................................................... 36
8 InterMetro Industries Corporation
Metro
TM
MPS-3111 Series SLA Power Supply Operations Manual Supplement
References
Document Number
L01-502 MetroTM 1700 Series Mobile Computing Workstation Operations Manual
L01-503 MetroTM 1800 Series Mobile Computing Workstation Operations Manual
Title
MetroTM MPS-3111 Series SLA Power Supply Operations Manual Supplement, Doc. No. L01-506
InterMetro Industries Corporation
9
Introduction
Mobile Rechargeable Power Supply
The MetroTM MPS-3111 Sealed Lead Acid (SLA) Power Supply is a rechargeable power source for the Metro
TM
Series Mobile Computing Workstations. The MetroTM SLA Power Supply is a fully automatic power supply charger system with a nominal DC output voltage of 12 Volts (V) and a battery capacity of 26 Amp-hours (Ah). When it is plugged into an AC outlet, it supplies the Mobile Computing Workstation system equipment while also charging the sealed lead acid battery. When unplugged from the outlet, the power supply switches automatically to supply the workstation equipment from the internal SLA rechargeable battery. The power supply is designed for continuous operation and service is not interrupted by plugging in or unplugging the power supply
MPS-3111 Sealed Lead Acid Power Supply
10 InterMetro Industries Corporation
Metro
TM
MPS-3111 Series SLA Power Supply Operations Manual Supplement
Power Supply Status
The status of the MPS-3111 series Power Supply is displayed by a remote Fuel Gauge display.
Remote Fuel Gauge Display
The Remote Fuel Gauge is embedded in the MetroTM Series Mobile Computing Workstation monitor mount at eye level height and is connected to the power supply. It displays the battery charge level and state with a series of LED indicators.
Remote Fuel Gauge Display
Features
The MetroTM MPS-3111 SLA Power Supply features:
Rugged, steel construction – built to last.
Remote Fuel Gauge at the user’s eye level.
SLA, 26 Ah capacity rechargeable battery.
TM
Fits conveniently in the base of the Metro
TM
Compatible with Metro
1700 and 1800 series Mobile Computing Workstations.
User manual supplement included.
Series Mobile Computing Workstations.
MetroTM MPS-3111 Series SLA Power Supply Operations Manual Supplement, Doc. No. L01-506
InterMetro Industries Corporation
11
Loading...
+ 25 hidden pages