Ce multimètre est conforme, dans son ensemble, aux prescriptions de
sécurité NFC 42010, CEI 414, VDE 410.
L'opérateur a une parfaite protection, s'il respecte les instructions de ce
manuel d'utilisation, par contre celle-ci est compromise pour une utilisation
inconsidérée.
REPONSE EN FREQUENCEREPONSE EN FREQUENCE
REPONSE EN FREQUENCE
REPONSE EN FREQUENCEREPONSE EN FREQUENCE
PLAGES DEPLAGES DE
PLAGES DE
FONCTIONSFONCTIONS
FONCTIONS
FONCTIONSFONCTIONS
VAC
dB
I AC
CALIBRESCALIBRES
CALIBRES
CALIBRESCALIBRES
5 V
15 V
50 V
150 V
500 V
1500 V
5 V AC
15 V AC
50 V AC
150 V AC
500 V AC
tous les
calibres
PLAGES DEPLAGES DE
FREQUENCESFREQUENCES
FREQUENCES
FREQUENCESFREQUENCES
40-45 Hz / 65 Hz-100 kHz
40-45 Hz / 65 Hz-20 kHz
40-45 Hz / 65 Hz-5 kHz
65 Hz à 1 kHz
65 Hz à 500 Hz
65 Hz à 500 Hz
40-45 Hz / 65 Hz-100 kHz
40-45 Hz / 65 Hz-20 kHz
40-45 Hz / 65 Hz-5 kHz
65 Hz à 1 kHz
65 Hz à 500 Hz
65 Hz à 500 Hz
PRECISIONPRECISION
PRECISION
PRECISIONPRECISION
fin d'échellefin d'échelle
fin d'échelle
fin d'échellefin d'échelle
± 4%
± 4%
± 4%
± 4%
± 4%
± 5 %
± 1,5 dB
(de + 0 dB à
+ 11 dB)
± 5%
1
MX 430B
1 - INTRODUCTION1 - INTRODUCTION
1 - INTRODUCTION
1 - INTRODUCTION1 - INTRODUCTION
1.1 GENERALITES1.1 GENERALITES
1.1 GENERALITES
1.1 GENERALITES1.1 GENERALITES
Ce multimètre analogique de résistance interne 40 000 W /V est destiné aux
électriciens aussi bien qu'aux électroniciens en assurant une large étendue
de mesure.
Un sélecteur unique fonctions/calibres simplifie son utilisation. Il dispose d'un
bon isolement (3 kV) et ne présente aucune partie métallique apparente.
De conception mécanique robuste, il est facilement transportable. En plus
d'une gaine de protection et d'un étui, on peut obtenir sur demande une
gamme variée d'accessoires qui étendent son domaine d'utilisation. Il comporte une béquille rétractable.
1.2 PARTICULARITES1.2 PARTICULARITES
1.2 PARTICULARITES
1.2 PARTICULARITES1.2 PARTICULARITES
Ce multimètre est conçu pour supporter une surcharge accidentelle brève de
220 V alternatifs sur tous les calibres, sans subir d'autres dommages que la
coupure des fusibles.
La protection des calibres < à 15 mA, des calibres ohmmètre et 50 et 150 mV
continus est assurée d'une manière originale par des éléments non linéaires.
Tous les calibres Volts sont protégés contre un branchement intempestif du
réseau par composants surdimensionnés. La protection des calibres > 15 mA
s'effectue par des fusibles, dont un à haut pouvoir de coupure 10 A / 80 kA
dans le commun qui concerne tous les calibres.
Les fusibles ainsi que les piles sont facilement accessibles à l'arrière du
boîtier. Les bornes d'entrée sont recouvertes d'un isolant qui accroît la
sécurité de l'utilisateur tout en permettant l'utilisation de cordons protégés ou
classiques.
Une fonction ohmmètre linéaire permet des mesures plus précises de faibles
résistances de 0 à 50 W et de 0 à 500 W .
2
MX 430B
1.3 CONSEILS GENERAUX1.3 CONSEILS GENERAUX
1.3 CONSEILS GENERAUX
1.3 CONSEILS GENERAUX1.3 CONSEILS GENERAUX
Pour éviter les fausses manoeuvres les plus courantes :
11
1 - Lorsque l'ordre de grandeur d'une mesure n'est pas connu, commencer
11
toujours par utiliser le calibre le plus élevé.
22
2 - Avant d'effectuer une mesure, vérifier que l'aiguille est au zéro des
22
échelles. Agir au besoin sur la vis de remise à zéro mécanique apparente au
dos du boîtier.
33
3 - Ne pas mesurer de tensions sur les calibres "ohmmètres" ou "intensités".
33
44
4 - Il est préférable de limiter dans le temps les mesures de fort débit.
44
Rappel : les mesures prolongées d'intensités élevées doivent être impérativement réalisées avec le multimètre hors gaine ou hors étui de transport.
55
5 - Lors de l'utilisation de la sonde THT, s'assurer que la sonde est parfaite-
55
ment propre, les poussières pouvant rendre sa surface conductrice. Vérifier
la continuité du circuit entre l'anneau de garde et les fiches bananes noires à
l'aide de l'ohmmètre du multimètre. La résistance ne doit pas dépasser 10
Ohms. Travailler dans un lieu très sec, sur un tapis isolant.
Eviter tout contact entre la main libre (ou une autre partie du corps) et des
pièces métalliques réunies à la terre.
Si possible, effectuer la mesure des hautes tensions de préférence après une
résistance qui, en cas d'accident, provoquerait une chute de tension importante.
66
Mesures de tensions non sinusoïdalesMesures de tensions non sinusoïdales
6 -
Mesures de tensions non sinusoïdales
66
Mesures de tensions non sinusoïdalesMesures de tensions non sinusoïdales
Le multimètre est étalonné en tensions sinusoïdales. Lorsque la tension n'est
plus sinusoïdale, l'indication donnée correspond à la "valeur moyenne" du
signal redressé.
Cette valeur peut être différente de celle de la tension efficace vraie. En cas
de doute, un contrôle à l'oscilloscope montrera la distorsion de la tension
alternative.
3
MX 430B
77
7 - Lors de l'emploi avec les pinces transformateur d'intensités 1/1000 : ne pas
77
changer de calibre sans avoir préalablement ôté la pince du circuit conducteur
mesuré. Cette opération permet d'éviter toute apparition d'une surtension au
secondaire de la pince.
8 8
Mesure de tensions continues avec sonde de filtrage TVMesure de tensions continues avec sonde de filtrage TV
8 -
Mesure de tensions continues avec sonde de filtrage TV
8 8
Mesure de tensions continues avec sonde de filtrage TVMesure de tensions continues avec sonde de filtrage TV
(Voir également notice particulière pour HA0902)
Ce filtre intègre les impulsions de tensions de fortes valeurs (par exemple sur
les circuits base de temps des récepteurs TV).
Attention Attention
Attention :
Attention Attention
Il est dangereux de prendre des mesures directement sur l'anode de tube
balayage ligne, où la tension en impulsions atteint des valeurs élevées
risquant d'endommager l'instrument. Points de mesure conseillés : grille du
tube balayage ligne ou base du transformateur ligne aux bornes de la capacité
de récupération.
1500 V (sur borne séparée)1500 V (sur borne séparée)
Classe de précision : 1,5 (3 sur calibre 1500 V)
Résistance interne : 40 kW / V (10 kW / V sur calibre 1500 V)
Extensions : 15 et 30 kV (voir sonde THT)
Calibres :Calibres :
5 - 15 - 50 - 150 - 500 V
Consommation : 250 µA
1500 V (sur borne séparée)1500 V (sur borne séparée)
1500 V (sur borne séparée)
1500 V (sur borne séparée)1500 V (sur borne séparée)
Classe de précision : 2,5 (4 sur calibre 1500 V) de 45 à 65 Hz
Résistance interne : 4 kW / V
Réponse en fréquence : voir tableau page 1
Mesure des niveaux en dB :Mesure des niveaux en dB :
Mesure des niveaux en dB :
Mesure des niveaux en dB :Mesure des niveaux en dB :
- 10 à + 56 d B0 dB = 1 mW / 600 W
Echelle directe - 10 à + 16 dB
Calibres :Calibres :
25 µ A (sur 50 mV et autres calibres tensions continues)
150 µA - 1.5 - 15 - 150 mA
1.5 - 15 A (sur bornes séparées)1.5 - 15 A (sur bornes séparées)
1.5 - 15 A (sur bornes séparées)
1.5 - 15 A (sur bornes séparées)1.5 - 15 A (sur bornes séparées)
Classe de précision : 1,5
Chute de tension : < 1.2 V
Extensions shunts 100 mV et 300 mV : 15 A à 500 A
1.5 - 15 A (sur bornes séparées)1.5 - 15 A (sur bornes séparées)
1.5 - 15 A (sur bornes séparées)
1.5 - 15 A (sur bornes séparées)1.5 - 15 A (sur bornes séparées)
Classe de précision : 2,5 de 45 à 65 Hz
Chute de tension : < 1.2 V
Extensions pinces 1/1000 : 250 A - 1000 A
Attention : Attention :
Attention : calibre 15 A (alternatif et continu), mesures limitées à 5 minutes
Attention : Attention :
(pour 10 A : durée de mesure permanente)
Calibres linéaires :Calibres linéaires :
Classe de précision : 2
Source de courant 3 mA interne, délivrée par pile 9 V, CEI 6F22
L'entrée étant en circuit ouvert, l'aiguille dévie en butée à droite, ce qui indique
que la source de courant débite en permanence.
Eviter de placer le sélecteur unique sur 50 et 500 Eviter de placer le sélecteur unique sur 50 et 500
Eviter de placer le sélecteur unique sur 50 et 500
Eviter de placer le sélecteur unique sur 50 et 500 Eviter de placer le sélecteur unique sur 50 et 500
plus ces calibres.plus ces calibres.
plus ces calibres.
plus ces calibres.plus ces calibres.
Calibres kCalibres k
Alimentation : Alimentation :
kW x 1: 1,5 V CEI R6
kW x 100 : 9 V CEI 6F22
2.6 MESURE DE LA TENSION DIRECTE DES SEMI-CONDUCTEURS2.6 MESURE DE LA TENSION DIRECTE DES SEMI-CONDUCTEURS
2.6 MESURE DE LA TENSION DIRECTE DES SEMI-CONDUCTEURS
2.6 MESURE DE LA TENSION DIRECTE DES SEMI-CONDUCTEURS2.6 MESURE DE LA TENSION DIRECTE DES SEMI-CONDUCTEURS
Calibre : Calibre :
Calibre : 500 W linéaire
Calibre : Calibre :
Courant : 3 mA
Lecture jusqu'à 1.5 V sur l'échelle noire 150 V (V : 100)
CalibreCalibre
Calibre
CalibreCalibre
kW x 1
kW x 100
WW
à échelles inversées : k à échelles inversées : k
W
à échelles inversées : k
WW
à échelles inversées : k à échelles inversées : k
Plage de mesurePlage de mesure
Plage de mesure
Plage de mesurePlage de mesure
0,1 k W à 200 k W
10 kW à 20 M W
W W
x 1 et kx 1 et k
W
x 1 et k
W W
x 1 et kx 1 et k
Courant max.Courant max.
Courant max.
Courant max.Courant max.
WW
W
WW
0.66 mA
40 µA
WW
lorsqu'on n'utilise lorsqu'on n'utilise
W
lorsqu'on n'utilise
WW
lorsqu'on n'utilise lorsqu'on n'utilise
x 100 x 100
x 100
x 100 x 100
Point milieuPoint milieu
Point milieu
Point milieuPoint milieu
2.5 k W
250 kW
6
MX 430B
2.7 MESURES DE TEMPERATURES (extension avec sonde)2.7 MESURES DE TEMPERATURES (extension avec sonde)
2.7 MESURES DE TEMPERATURES (extension avec sonde)
2.7 MESURES DE TEMPERATURES (extension avec sonde)2.7 MESURES DE TEMPERATURES (extension avec sonde)
Plage :Plage :
Plage : - 50°C à + 150°C
Plage :Plage :
Voir caractéristiques détaillées sur notice particulière à la sonde de température.
2.8 PROTECTION2.8 PROTECTION
2.8 PROTECTION
2.8 PROTECTION2.8 PROTECTION
Surcharge admissible : 220 V AC
Tous calibres : fusible 10 A (500 V - 100 kA) dans le commun
Haut pouvoir de coupure
Calibres intensité (> 15 mA) : fusible 0,16 A semi-temporisé
Les calibres protégés par des éléments non linéaires ne sont opérationnels
que quelques minutes après avoir subi une quelconque surcharge.
Equipage à suspensions par bandes protégé par diodes.
1 fusible 0.16 A semi-temporiséAA0411
1 fusible 10 A rapide 500 V HPCAA2346
1 jeu de cordonsAG0476
1 pile 9 V 6F 22 CEIAL0020
1 pile 1,5 V R6 CEIAL0008
2.9.22.9.2
Livrés en option sur demandeLivrés en option sur demande
2.9.2
Livrés en option sur demande
2.9.22.9.2
Livrés en option sur demandeLivrés en option sur demande
Sonde THT 15 kVHT0215 - HA0873
Sonde THT 30 kVHT0216 - HA1059
Sonde de température -50°C à +150°CHA1159
Pince transformateur 1/1000 S 15x17 mmAM0012
Pince transformateur 1/1000 Ø 50 mmAM0015
Pince transformateur 1/1000 Ø 100 mmHA0768
Prise multampèreHA0709
Shunt 50 mV 50 AHA0512
Shunt 50 mV 100 AHA0511
Shunt 50 mV 500 AHA1029
Sonde de filtrageHA0902
Jeu de grip fils avec cordonsHA0932
EtuiAE0181
Gaine de protectionMC0136
Nota :Nota :
1) 1)
Nota :
1) La prise multampère favorise les mesures d'intensités sans
Nota :Nota :
1) 1)
nécessiter l'ouverture du circuit de mesure.
2) 2)
2) La sonde de filtrage évite les pointes HF lors de mesures de V
2) 2)
continu.
MX 430B
8
MX 430B
3 - MODE D'EMPLOI3 - MODE D'EMPLOI
3 - MODE D'EMPLOI
3 - MODE D'EMPLOI3 - MODE D'EMPLOI
3.1 MISE EN PLACE DE LA PILE3.1 MISE EN PLACE DE LA PILE
3.1 MISE EN PLACE DE LA PILE
3.1 MISE EN PLACE DE LA PILE3.1 MISE EN PLACE DE LA PILE
Débrancher les cordons de mesure et veiller à ce que le multimètre soit
en position hors-service.
La pile est placée dans un compartiment au dos du multimètre.
Après avoir soulevé la béquille à l'arrière du multimètre (voir figure 1), suivre
les instructions suivantes pour ouvrir le compartiment :
1 - Resserrer les bras latéraux de la béquille
2 - Oter la vis de sécurité.
3 - Appuyer dans le sens de la flèche.
4 - Pousser le couvercle pour le faire coulisser dans le sens de la
flèche.
5 - Remise à niveau du galvanomètre
La pile à utiliser est une pile 9 V 6LF22.
Fig.1
2
5
ATTENTION :ATTENTION :
ATTENTION :Bien débrancher les cordons de mesure avant d'ou-
ATTENTION :ATTENTION :
3
4
vrir le compartiment piles et fusibles
9
MX 430B
3.2 REMPLACEMENT DES FUSIBLES3.2 REMPLACEMENT DES FUSIBLES
3.2 REMPLACEMENT DES FUSIBLES
3.2 REMPLACEMENT DES FUSIBLES3.2 REMPLACEMENT DES FUSIBLES
Lors d'un échange, bien remplacer chaque fusible par son équivalent.
Attention :Attention :
Attention :
Attention :Attention :
Une erreur sur le type ou l'intensité nominale peut compromettre la protection
des circuits du multimètre.
3.3 MODE D'EMPLOI3.3 MODE D'EMPLOI
3.3 MODE D'EMPLOI
3.3 MODE D'EMPLOI3.3 MODE D'EMPLOI
3.3.1 Réétalonnage3.3.1 Réétalonnage
3.3.1 Réétalonnage
3.3.1 Réétalonnage3.3.1 Réétalonnage
Il ne doit être entrepris qu'en cas de stockage prolongé (> 1 an) ou après
réparations effectuées par l'utilisateur (hors période de garantie).
NotaNota
Nota : Pour accéder aux circuits, enlever 4 vis (dont 2 sous le couvercle du
NotaNota
logement piles + fusibles) à l'arrière du multimètre. Vérifier le zéro mécanique.
Utiliser des sources étalon de classe 0.5.Utiliser des sources étalon de classe 0.5.
Utiliser des sources étalon de classe 0.5.
Utiliser des sources étalon de classe 0.5.Utiliser des sources étalon de classe 0.5.
- Injecter 50 mVDC sur le calibre 50 mV DC (25 µA DC). Régler la fin d'échelle
avec R33.
- Injecter 150 µA DC sur le calibre 150 µA DC. Régler la fin d'échelle avec R34.
- Injecter 25 µA DC sur le calibre 50 mVDC (25 µA DC) et reprendre
éventuellement le réglage de R34 dansle cas où l'erreur dépasserait 0.8 %.
- Injecter 250 µA AC sur le calibre 5 V AC. Régler la fin de l'échelle avec R35.
- Injecter 1.5 mA AC sur le calibre 1.5 mA AC. Régler la fin d'échelle avec R36.
- Résitance étalon 50 W à l'entrée - COM V mA kW / W.
Calibre linéaire 50 W : régler la fin d'échelle avec R37.
Vérifier la teneur en précision de tous les autres calibres du multimètre.
10
MX 430B
3.3.2 Fonction
1) Cordons de mesure entre bornes COM et mA V
2) S'assurer que la résistance à mesurer n'est pas sous tension.
3) Ohmmètre à échelle linéaire directe (protection par thermistance et
varistance contre un branchement accidentel sur réseau 220 V AC).
Sélecteur surSélecteur sur
Sélecteur sur
Sélecteur surSélecteur sur
Remarque :Echelle W linéaire avec 0 à gauche, l'aiguille dévie vers la
Attention :Ne pas laisser le sélecteur sur un calibre linéaire après
4) Ohmmètre à échelle logarithmique inverse
Amener l'aiguille au zéro de l'échelle verte à l'aidedu tarage 0 W en courtcircuitant les pointes de touche des cordons de mesure.
Sélecteur surSélecteur sur
Sélecteur sur
Sélecteur surSélecteur sur
NotaNota
Nota : E n l'absence de déviation, vérifier l'état du fusible 10 A
NotaNota
WW
W
WW
WW
W / kW
WW
enen
en
Lecture sur échelleLecture sur échelle
Lecture sur échelle
Lecture sur échelleLecture sur échelle
50 W
500 W
Le calibre linéaire 500
W W
COM k
(lecture sur l'échelle noire 150 en V : 100, soit jusqu'à 1.5 V).
kW x 1
kW x 10
W W
W /
W des semi-conducteurs sous un courant de 3 mA
W W
W W
droite pour des valeurs croisantes
(fin d'échelle 50 ou 500 W)
En circuit ouvert ou R µ l'aiguille est en butée.
utilisation.
50 noire
50 noire
WW
W sert à mesurer la tension directe.
WW
Lecture sur échelleLecture sur échelle
Lecture sur échelle
Lecture sur échelleLecture sur échelle
kW
verte
enen
W x 1
W x 10
dede
de
dede
0.1 kW à 200 kW
10 kW à 20 MW
11
3.3.3 Fonction V DC3.3.3 Fonction V DC
3.3.3 Fonction V DC
3.3.3 Fonction V DC3.3.3 Fonction V DC
Cordons de mesure entre bornes :
- COM et mA V k
- COM et 1500 V pour le calibre 1500 V
WW
W pour les calibres 50 mV à 500 V
WW
MX 430B
CalibresCalibres
Calibres
CalibresCalibres
50 mV
150 V
0.5 V
1.5 V
5 V
15 V
50 V
150 V
500 V
1500 V
Nota :Nota :
Nota : En l'absence de déviation, vérifier l'état des fusibles 10 A.
Nota :Nota :
3.3.4 Fonction V AC3.3.4 Fonction V AC
3.3.4 Fonction V AC
3.3.4 Fonction V AC3.3.4 Fonction V AC
Cordons de mesure entre bornes :
- COM et mA V k
- COM et 1500 V pour le calibre 1500 V.
PositionPosition
Position
PositionPosition
du sélecteurdu sélecteur
du sélecteur
du sélecteurdu sélecteur
50 mV DC
150 V DC
0.5 V DC
1.5 V DC
5 V DC
15 V DC
50 V DC
150 V DC
500 V DC
500 V DC
WW
W pour les calibres 5 à 500 V.
WW
EchelleEchelle
Echelle
EchelleEchelle
50 noire
150 noire
50 noire
150 noire
50 noire
150 noire
50 noire
150 noire
50 noire
150 noire
Unité/facteurUnité/facteur
Unité/facteur
Unité/facteurUnité/facteur
mV x 1
mV x 1
mV x 10
V : 100
V : 10
V : 10
V x 1
V x 1
V x 10
V x 10
12
MX 430B
CalibresCalibres
Calibres
CalibresCalibres
5 V
15 V
50 V
150 V
500 V
1500 V
Nota :Nota :
Nota : En l'absence de déviation, vérifier le fusible 10 A.
Nota :Nota :
DécibelmètreDécibelmètre
Décibelmètre :
DécibelmètreDécibelmètre
Comparaison entre 2 tensions V2 > V1
Gain V2 / V1 : lecture V2 dB - lecture V1 dB
Mesure non exploitable dansl e premier tiers de l'échelle et sur le calibre
1500 V AC
Lecture directe - 10 à + 16 dB sur le calibre 5 V AC
(0 dB = 0.775 V soit 1 mW / 600 W )
Ajouter + 10 dB sur le calibre 15 V AC
+ 20 dB sur le calibre 50 V AC
+ 30 dB sur le calibre 150 V AC
+ 40 dB sur le calibre 500 V AC
PositionPosition
Position
PositionPosition
du sélecteurdu sélecteur
du sélecteur
du sélecteurdu sélecteur
5 V AC
15 V AC
50 V AC
150 V AC
500 V AC
500 V AC
EchelleEchelle
Echelle
EchelleEchelle
5 rouge
150 noire
50 noire
150 noire
50 noire
150 noire
Unité/facteurUnité/facteur
Unité/facteur
Unité/facteurUnité/facteur
V x 1
V : 10
V x1
V x1
V x10
V x10
13
MX 430B
3.3.5 Fonction mA DC3.3.5 Fonction mA DC
3.3.5 Fonction mA DC
3.3.5 Fonction mA DC3.3.5 Fonction mA DC
Cordons de mesure entre bornes :
- COM et mA V k
- COM et 1.5 A pour le calibre 1.5 A (15 A pour le calibre 15 A)
CalibresCalibres
Calibres
CalibresCalibres
25 µA
150 µA
1.5 mA
15 mA
150 mA
1.5 A
15 A*
Nota :Nota :
Nota : En l'absence de déviation sur les calibres 1.5 V et 15 A, vérifier le
Nota :Nota :
Attention Attention
Attention : Le temps de mesure d'un courant de 15 A est limité à 5 minutes.
Attention Attention
3.3.6 Fonction mA AC
Cordons de mesure entre bornes :
- COM et mA kW / W pour les calibres 1.5 mA à 150 mA
- COM et 1.5 A pour le calibre 1.5 A (15 A pour le calibre 15 A).
CalibresCalibres
Calibres
CalibresCalibres
1.5 mA
15 mA
150 mA
15 A
15 A*
W W
WW
W /
W pour les calibres 25 µA à 150 mA
W W
WW
Unité/facteurUnité/facteur
Unité/facteur
PositionPosition
Position
PositionPosition
du sélecteurdu sélecteur
du sélecteur
du sélecteurdu sélecteur
50 mV DC
150 µA DC
1.5 mA DC
15 mA DC
150 mA DC
150 mA DC
150 mA DC
fusible 10 A (sur les autres calibres
0.16 A).
Un courant de 10 A peut être mesuré en permanence.
> 3 A : utiliser des cordons de section convenable.
Nota : En l'absence de déviation sur les calibres 1.5 et 15 A, vérifier l'état
Nota :Nota :
du fusible 10 A (sur les autres calibres > 15 mA, vérifier celui du
fusible 0.16 A).
Attention : Attention :
*
Attention : Le temps de mesure d'un courant de 15 A est limité à 5 minutes.
Attention : Attention :
Un courant de 10 A peut être mesuré en permanence dans le seul
cas où le courant est parfaitement sinusoïdal. En présence d'un
signal non sinusoïdal, la valeur efficace vraie correspondant à 10 A
"valeur moyenne du signal redressé" peut dépasser la limite eficace
vraie et provoquer un échauffement non souhaitable.
RappelRappel
Rappel : Toute mesure de courant fort doit s'effectuer lorsque le multimètre
RappelRappel
est placé hors gaine de protection ou hors étui de transport.
> 3 A : utiliser des cordons de section convenable.
15
3.4 UTILISATION DES ACCESSOIRES3.4 UTILISATION DES ACCESSOIRES
3.4 UTILISATION DES ACCESSOIRES
3.4 UTILISATION DES ACCESSOIRES3.4 UTILISATION DES ACCESSOIRES
3.4.1 Shunts 50 mV3.4.1 Shunts 50 mV
3.4.1 Shunts 50 mV
3.4.1 Shunts 50 mV3.4.1 Shunts 50 mV
Multimètre sur
Calibre 50 mV DC
MX 430B
Shunts 100 mVShunts 100 mV
Shunts 100 mV
Shunts 100 mVShunts 100 mV
50 A
100 A
500 A
3.4.2 Prise multampère3.4.2 Prise multampère
3.4.2 Prise multampère (voir notice particulière)
3.4.2 Prise multampère3.4.2 Prise multampère
directement
à l'arrière
alimention
réseau
Appuyer sur le poussoir, mettre la fonction mA du multimètre en service
(ouverture interposée sur un conducteur réseau pour mesure série d'intensité
jusqu'à 10 A). Cette faculté évite d'ouvrir un circuit, un câble pour effectuer des
mesures rapides d'intensité (réseau ou autre).
BB
jusqu'au point 10 (x 100) de l'échelle 15 rouge
3.4.4 Sonde de température - 50°C à + 150°C 3.4.4 Sonde de température - 50°C à + 150°C
3.4.4 Sonde de température - 50°C à + 150°C (voir notice particulière)
3.4.4 Sonde de température - 50°C à + 150°C 3.4.4 Sonde de température - 50°C à + 150°C
Utiliser des calibres V DC de sensibilité convenable avec celle de la sonde
1 mV/°C ou 10 mV/°C (inverser la polarité du branchement des cordons de
mesures pour des températures négatives).
Calibre adoptéCalibre adopté
Calibre adopté
Calibre adoptéCalibre adopté
150 mV DC
50 mV DC
SensibilitéSensibilité
Sensibilité
SensibilitéSensibilité
1 mV/°C
10 mV/°C
1 mV/°C
10 mV/°C
à fonction mA AC
AA
A
AA
Plage de mesurePlage de mesure
Plage de mesure
Plage de mesurePlage de mesure
- 50°C à + 105°C
- 1°5C à + 15°C
- 50°C à + 50°C
- 5°C à + 5°C
17
3.4.5 Sondes THT3.4.5 Sondes THT
3.4.5 Sondes THT
3.4.5 Sondes THT3.4.5 Sondes THT
- 30 kV et 15 kV DC
- Branchement entre douilles - COM et mA V k
- Calibre 25 µAV DC (50 mV DC)
- Lecture sur l'échelle noire 150 (V x 200 ou V x 100)
3.4.6 Sonde de filtrage TV3.4.6 Sonde de filtrage TV
3.4.6 Sonde de filtrage TV (voir notice particulière)
3.4.6 Sonde de filtrage TV3.4.6 Sonde de filtrage TV
- Elimine pointes V AC HF
- Utilisé sur calibres V DC 500 V et 1500 V
W / WW / W
W / W
W / WW / W
MX 430B
mA V W
- COM
18
MX 430B
ANALOG MULTIMETERANALOG MULTIMETER
ANALOG MULTIMETER
ANALOG MULTIMETERANALOG MULTIMETER
MX430BMX430B
MX430B
MX430BMX430B
INSTRUCTION BOOKINSTRUCTION BOOK
INSTRUCTION BOOK
INSTRUCTION BOOKINSTRUCTION BOOK
Please note :Please note :
Please note :
Please note :Please note :
This mutimeter was built according to the following regulations : security :
NFC 42010, CEI 414, VDE 410
The user is perfectly protected providing he repects the instructions contained
in this booklet. However protection will be impaired if the instructions are
ignored.
FREQUENCY RESPONSEFREQUENCY RESPONSE
FREQUENCY RESPONSE
FREQUENCY RESPONSEFREQUENCY RESPONSE
ACCURACYACCURACY
ACCURACY
FUNCTIONSFUNCTIONS
FUNCTIONS
FUNCTIONSFUNCTIONS
V AC
dB
I AC
RANGESRANGES
RANGES
RANGESRANGES
5 V
15 V
50 V
150 V
500 V
1500 V
5 V AC
15 V AC
50 V AC
150 V AC
500 V AC
all
ranges
FREQUENCYFREQUENCY
FREQUENCY
FREQUENCYFREQUENCY
RANGESRANGES
RANGES
RANGESRANGES
40-45 Hz / 65 Hz-100 kHz
40-45 Hz / 65 Hz-20 kHz
40-45 Hz / 65 Hz-5 kHz
65 Hz to 1 kHz
65 Hz to 500 Hz
65 Hz to 500 Hz
40-45 Hz / 65 Hz-100 kHz
40-45 Hz / 65 Hz-20 kHz
40-45 Hz / 65 Hz-5 kHz
65 Hz to 1 kHz
65 Hz to 500 Hz
65 Hz to 500 Hz
ACCURACYACCURACY
end of scaleend of scale
end of scale
end of scaleend of scale
± 4%
± 4%
± 4%
± 4%
± 5%
± 5%
± 1.5 dB
(from + 0 dB
to + 11 dB)
± 5%
19
MX 430B
1 - INTRODUCTION1 - INTRODUCTION
1 - INTRODUCTION
1 - INTRODUCTION1 - INTRODUCTION
1.1 GENERAL1.1 GENERAL
1.1 GENERAL
1.1 GENERAL1.1 GENERAL
This 40 000 W / V analog multimeter with its wide range of measurement
capabilities is perfectly adapted to the needs of electrical and electronic
engineer. A single combined range and function rotary switch will make this
instrument easy to use.
It has a good insulation (3 kV) and has no metallic protruding parts. Of rugged
construction it is handy to carry. As well as rubber shock absorber surround
or a carrying case many accessories are available on request. The instrument
is fitted with a folding stand.
1.2 PARTICULARITIES1.2 PARTICULARITIES
1.2 PARTICULARITIES
1.2 PARTICULARITIES1.2 PARTICULARITIES
This multimeter will support an accidental short overload of 240 V AC on all
ranges without other damage than blown fuses. The protection of current
ranges (< 15 mA) and 50 - 150 mV DC relies on non linear components. All
volts ranges are protectec against mains accidental ocerloads through the
use of generously rated components. The protection of current ranges
(> 15 mA) is obtained through fuses. One of them has a high current cuttingoff power 10 A/80 kA in the common.
Fuses and batteries are easily accessible at the back of the case. A linear
ohmmeter gives constant precision and resolution at low resistance i. e. :
ranges 0 - 50 W and 0 - 500 W .
1.3 GENERAL INSTRUCTIONS1.3 GENERAL INSTRUCTIONS
1.3 GENERAL INSTRUCTIONS
1.3 GENERAL INSTRUCTIONS1.3 GENERAL INSTRUCTIONS
1.1.
1. If the order of a measurement is not known, start measuring with
1.1.
the meter set to its highest range ; turn down later if necessary.
Highest accuracy is obtained when the deviation is greatest.
2.2.
2. Before making a measurement, check that the pointer is at zero.
2.2.
If not, adjust with the screw situated at the rear.
3.3.
3. Make sure that the function switch is correctly set before making
3.3.
a measurement, e.g. do not try to measure volts when the function
switch is at ohms or at mA.
20
MX 430B
4.4.
4. Do not prolong measurement on high current ranges.High current
4.4.
measurements must be carried on only with the instrument out of
its carrying case (or out of its rubber shock absorber).
5.5.
5. When using EHT probe
5.5.
Make sure that the probe is perfectly clean, dust may reduce the
insulating properties of the surface. Check the continuity between
the guard ring and the black banana plugs. Resistance should not
be above 10 W .
Work in a dry place on an insulating mat. Avoid all contacts
between the free hand or any other part of the body - and any
metallic objects which may be grounded.
If possible, do not make measurements directly at the source of
voltage, try to do it after some circuit resistance which will provide
a voltage drop in case of accident.
6. 6.
6. No sinusoïdal wave form measurement
6. 6.
The multimeter is calibrated for sinusoïdal waveform. When
different, the indication given will correspond to the average or
mean value. This value can be different from RMS and in doubt,
check on an oscilloscope.
7.7.
7. When using a clip-on ammeter with 1/1000 ratio do not change the range
7.7.
before removing the clip-on from the circuit under test. This will
avoid having transients at the secondary output of the
clip-on.
8.8.
8. DC measurements with TV filter probe. See also instructions
8.8.
book of HA0902. This filter integrates high voltage pulses (i. e. on
TB of TV receivers).
WARNINGWARNING
WARNING : It i s dangerous to measure directly the anode of the line sweep
WARNINGWARNING
tube where pulses attain high values which can damage the
instruments, it is advisable to measure on the grid of the tube or at
the base of the transformer by the boost condenser.
21
MX 430B
2 - SPECIFICATIONS2 - SPECIFICATIONS
2 - SPECIFICATIONS
2 - SPECIFICATIONS2 - SPECIFICATIONS
2.1. DC VOLTAGE2.1. DC VOLTAGE
2.1. DC VOLTAGE
2.1. DC VOLTAGE2.1. DC VOLTAGE
Ranges :Ranges :
Ranges :
Ranges :Ranges :
50 - 150 mV
0.5 - 1.5 - 5 - 15 - 50 - 150 - 500 V
FSD current : 25 µA
1500V (on separate input)
Accuracy at FSD : ± 1.5 % ( ± 3 % on 1500 V range)
Sensitivity : 40 k W / V (10 k W / V on 1500 V range)
Extensions : 15 and 30 kV (see EHT probes)
2.2. AC VOLTAGE2.2. AC VOLTAGE
2.2. AC VOLTAGE
2.2. AC VOLTAGE2.2. AC VOLTAGE
Ranges :Ranges :
Ranges :
Ranges :Ranges :
5 - 15 - 50 - 150 - 500 V
FSD current : 250 µA
1500V (on separate input)
Accuracy at FSD : ± 2.5 % ( ± 4 % on 1500 V range) ref. 45 - 65 Hz
Sensitivity : 4 k W /V
Frequency response : see table page 19
Decibelmeter :Decibelmeter :
Decibelmeter :
Decibelmeter :Decibelmeter :
- 10 to + 56 dB 0 dB = 1 mW / 600 W
Direct scale 0 to + 16 dB
2.3. DC CURRENT2.3. DC CURRENT
2.3. DC CURRENT
2.3. DC CURRENT2.3. DC CURRENT
Ranges :Ranges :
Ranges :
Ranges :Ranges :
25 µ A (on 50 mV and any other V DC range with FSD current 25 µA)
150 µA - 1.5 - 15 - 150 mA
1.5 - 15 A (on separate inputs)
Accuracy at FSD : ± 1.5 %
Voltage drop :
Extension shunts : 100 and 300 mV 15 A up to 500 A
< 1.2 V
22
MX 430B
2.4 AC CURRENT2.4 AC CURRENT
2.4 AC CURRENT
2.4 AC CURRENT2.4 AC CURRENT
Ranges :Ranges :
Ranges :
Ranges :Ranges :
1.5 - 15 - 150 mA
1.5 - 15 A (on separate inputs)1.5 - 15 A (on separate inputs)
1.5 - 15 A (on separate inputs)
1.5 - 15 A (on separate inputs)1.5 - 15 A (on separate inputs)
Accuracy at FSD (ref. 45 to 65 Hz): ± 2.5 %
Voltage drop : < 1.2 V
Extensions : 1/1000 : 250 - 1000 A (with clip-on transformers)
Warning : Warning :
Warning : AC and DC 15 A ranges (measurement limited to 5 minutes)
Warning : Warning :
(10 A : permanent)
2.5 OHMMETRE2.5 OHMMETRE
2.5 OHMMETRE
2.5 OHMMETRE2.5 OHMMETRE
Linear rangesLinear ranges
Linear ranges : 0 - 50 W , 0 - 500 W
Linear rangesLinear ranges
Accuracy at FSD : ± 2 %
Internal source 3 mA DC source from a dry cell 9 V IEC 6F 22
When input is not loaded, the pointer deflects to the right, indicating that power
is on.
Do not leave the switch on 50 or 500 Do not leave the switch on 50 or 500
Do not leave the switch on 50 or 500 W
Do not leave the switch on 50 or 500 Do not leave the switch on 50 or 500
kk
range is logarithmic the scale is reversed. range is logarithmic the scale is reversed.
kW
range is logarithmic the scale is reversed.
kk
range is logarithmic the scale is reversed. range is logarithmic the scale is reversed.
position after use. position after use.
position after use.
position after use. position after use.
RangesRanges
Ranges
RangesRanges
kW x 1
kW x 100
Accuracy at MSD : Accuracy at MSD :
Accuracy at MSD : ± 10 %
Accuracy at MSD : Accuracy at MSD :
Power supply :Power supply :
Power supply :
Power supply :Power supply :
kW x 1 : 1,5 V IEC R6
kW x 100 : 9 V IEC 6F22
2.6 SEMI-CONDUCTOR DIRECT VOLTAGE MEASUREMENT2.6 SEMI-CONDUCTOR DIRECT VOLTAGE MEASUREMENT
2.6 SEMI-CONDUCTOR DIRECT VOLTAGE MEASUREMENT
2.6 SEMI-CONDUCTOR DIRECT VOLTAGE MEASUREMENT2.6 SEMI-CONDUCTOR DIRECT VOLTAGE MEASUREMENT
Range : Range :
Range : 500 W linear
Range : Range :
Current : 3 mA
Read direct junction voltage up to 1.5 V
(V : 100 on black scale 150)
fromfrom
from
fromfrom
0.1 k W to 200 k W
10 kW to 20 MW
max.max.
max.
max.max.
currentcurrent
current
currentcurrent
0.66 mA
40 µA
Mid scaleMid scale
Mid scale
Mid scaleMid scale
deviationdeviation
deviation
deviationdeviation
2.5 k W
250 kW
23
MX 430B
2.7 TEMPERATUR MEASUREMENT (Probe extension)2.7 TEMPERATUR MEASUREMENT (Probe extension)
2.7 TEMPERATUR MEASUREMENT (Probe extension)
2.7 TEMPERATUR MEASUREMENT (Probe extension)2.7 TEMPERATUR MEASUREMENT (Probe extension)
Range : Range :
Range : - 50°C bis + 150°C
Range : Range :
See also instructions book of HA1159 probe.
2.8 PROTECTION2.8 PROTECTION
2.8 PROTECTION
2.8 PROTECTION2.8 PROTECTION
Maximum overloadMaximum overload
Maximum overload : 220 V AC
Maximum overloadMaximum overload
All rangesAll ranges
All ranges : high current cutting-off power (500 V - 80 kA) fuse in the common
All rangesAll ranges
(10 A)
DC current ranges (> 15 mA) : 0.16 A semi-delayed fuse
Ranges protected through non linear components are not usable before a few
minutes after having been overloaded.
Taut band movement protected by diodes.
2.9 GENERAL2.9 GENERAL
2.9 GENERAL
2.9 GENERAL2.9 GENERAL
Dimensions :Dimensions :
Dimensions :width : 110 mm - height : 45 mm
Dimensions :Dimensions :
Weight :Weight :
Weight :0,5 kg approximate
Weight :Weight :
depth : 185 mm
24
MX 430B
2.10 ACCESSORIES2.10 ACCESSORIES
2.10 ACCESSORIES
2.10 ACCESSORIES2.10 ACCESSORIES
2.10.1 Delivered with the instrument2.10.1 Delivered with the instrument
2.10.1 Delivered with the instrument
2.10.1 Delivered with the instrument2.10.1 Delivered with the instrument
10.16 A semi delayed fuseAA 0411
110 A high current fuseAA 2346
1Leads setAG 0328
19 V 6F22 IEC dry cell (PP3)AL 0020
11.5 V R6 IEC dry cellAL 0008
2.10.2 Delivered on request2.10.2 Delivered on request
2.10.2 Delivered on request
2.10.2 Delivered on request2.10.2 Delivered on request
15 kV DC EHT probeHA0873 - HT0215
30 kV DC EHT probeHA1059 - HT0216
Temperature probe -50°C to +150°CHA1159
Clip-on transformer 1/1000 S 11x15 mmAM0010
Clip-on transformer 1/1000 Ø 50 mmAM0015
Clip-on transformer 1/1000 Ø 100 mmHA0768
Multicurrent connectorHA0709
Shunts 50 mV 50 A DCHA0512
Shunts 50 mV 1000 A DCHA0511
Shunts 50 mV 500 A DCHA1029
TV filter probeHA0902
Leads set with grip testHA0932
Carrying caseAE0181
Rubber shock absorberMC0136
Nota:Nota:
1) 1)
Nota:
1) The multicurrent connector allows to measure currents without
Nota:Nota:
1) 1)
opening the measuring circuit
2)2)
2) The TV filter probe avoids any high peak with HF pulses on DC
2)2)
voltage ranges
25
3 - WORKING INSTRUCTIONS - CALIBRATION3 - WORKING INSTRUCTIONS - CALIBRATION
3 - WORKING INSTRUCTIONS - CALIBRATION
3 - WORKING INSTRUCTIONS - CALIBRATION3 - WORKING INSTRUCTIONS - CALIBRATION
3.1 BATTERIES3.1 BATTERIES
3.1 BATTERIES
3.1 BATTERIES3.1 BATTERIES
MX 430B
3
2
5
4
Slide the lid at the back of the meter to open
batteries and fuses compartment:
0 - Pull the stand up.
1 - Press the legs of the stand towards the
center.
2 - Undo the screw.
3 - 4 - Slide towards the arrow as shown,
the stand and the back together, so as to
uncover the batteries compartment.
5 - Galvanometer zero adjustment pointer
Place the 9 V PP3 and 1.5 V R6 batteries as indicated.
Remove test leads before opening the batteries compartment.
WarningWarning
Warning : Disconnect the leads before opening the fuses and battery case.
WarningWarning
3.2 FUSES3.2 FUSES
3.2 FUSES
3.2 FUSES3.2 FUSES
When replacing fuse, use the right type.
WarningWarning
Warning : Wrong fuse replacement will endanger meter safety.
WarningWarning
26
MX 430B
3.3 - OPERATION3.3 - OPERATION
3.3 - OPERATION
3.3 - OPERATION3.3 - OPERATION
3.3.1 Calibration3.3.1 Calibration
3.3.1 Calibration
3.3.1 Calibration3.3.1 Calibration
Must be done after long storage (> 1 year) or after any repair over the warranty
period.
Nota Nota
Nota : Undo 4 screws (2 inside the fuses + cell (s) compartment) at the
Nota Nota
back of the instrument to get access to internal circuits. Check that
the pointer is at zero.
The accuracy of the standard sources must be The accuracy of the standard sources must be
The accuracy of the standard sources must be
The accuracy of the standard sources must be The accuracy of the standard sources must be
- 50 mV DC range (25 µA DC) : with 50 mV DC at input. Adjust R33 to make
the pointer deflect to FSD
- 150 µA DC range : with 150 µA DC at input. Adjust R34 to make the pointer
deflect to FSD
- 50 mV DC/25 µ A DC range : with 25 µA DC at input. Adjust R34 if necessary
(if error would exceed 0.8 %)
- 5 V AC range : with 250 µA AC at input. Adjust R35 to make the pointer deflect
to FSD
- 1.5 mA AC range : with 1.5 mA AC 50 Hz at input. Adjust R36 to make the
pointer deflect to FSD
- Standard resistance at ohmmeter (linear 50 W range) input. Adjust R37 to
make the pointer deflect to FSD.
Check the expected accuracy on each other range of the multimeter.
± ±
0.5 % at FSD0.5 % at FSD
±
0.5 % at FSD
± ±
0.5 % at FSD0.5 % at FSD
27
MX 430B
3.3.2 3.3.2
Function Function
3.3.2 W
Function
3.3.2 3.3.2
Function Function
1) Leads plugged into : - COM and mA V / kW / W sockets
2) Make sure that there is no voltage across the resistance to be tested
Linear ohmmeter Linear ohmmeter
3)
Linear ohmmeter (protected through thermistor and varistor from any
Linear ohmmeter Linear ohmmeter
accidental connection to 240 V AC)
Selector toSelector to
Selector to
Selector toSelector to
50 W
500 W
With the 500 W one can mesure the direct junction voltage of a semi-
conductor connected as follows :
- C O M mA V k W / W . Constant curent 3 mA : read up to 1.5 V on black
scale 150 (V : 100).
N. B.N. B.
N. B. : Linear scale (L. H. of the scale the pointer deflects to the right as a
N. B.N. B.
function of resistance up to 50 or 500 W with input open
(R
scale.
WarningWarning
Warning : D o not leave the selector at 50 or 500 W with nothing at input.
WarningWarning
Logarithmic ohmmeter Logarithmic ohmmeter
4)
Logarithmic ohmmeter
Logarithmic ohmmeter Logarithmic ohmmeter
Selector toSelector to
Selector to
Selector toSelector to
Short the leads prods. Turn the W control to set the pointer to 0 W (green scale)
with the function selector at W .
kW x 1
kW x 100
5) If the pointer does not deflect check 10 A fuse
Read on scaleRead on scale
Read on scale
Read on scaleRead on scale
50
50
) the pointer will fly to the R.H.S. of the
Read on green scaleRead on green scale
Read on green scale
Read on green scaleRead on green scale
kW
green
fromfrom
from
fromfrom
W x 1
W x 10
fromfrom
from
fromfrom
0.1 k W up to 200 k W
10 kW up to 20 M W
28
MX 430B
3.3.3 V DC Function3.3.3 V DC Function
3.3.3 V DC Function
3.3.3 V DC Function3.3.3 V DC Function
Leads plugged into :
- COM and mA V / kW / W sockets (50 mV to 500 V ranges)
- COM and 1500 V sockets (1500 V range)
RangesRanges
Ranges
RangesRanges
50 mV
150 mV
0.5 V
1.5 V
5 V
15 V
50 V
150 V
500 V
1500 V
NotaNota
Nota : I f the pointer does not deflect : check 10 A fuse
NotaNota
SelectorSelector
Selector
SelectorSelector
positionposition
position
positionposition
50 mV DC
150 mV DC
0.5 V DC
1.5 V DC
5 V DC
15V DC
50 V DC
150 V DC
500 V DC
500 V DC
Black scaleBlack scale
Black scale
Black scaleBlack scale
50
150
50
150
50
150
50
150
50
150
Unit/FactorUnit/Factor
Unit/Factor
Unit/FactorUnit/Factor
mV x 1
mV x 1
mV x 10
V : 100
V : 10
V : 10
V x 1
V x 1
V x 10
V x 10
29
3.3.4 V AC Function3.3.4 V AC Function
3.3.4 V AC Function
3.3.4 V AC Function3.3.4 V AC Function
Leads plugged into :
- COM and mA V / kW / W (5 to 500 V ranges)
- COM and 1500 V sockets (1500 V range)
MX 430B
RangesRanges
Ranges
RangesRanges
5 V
15 V
50 V
150 V
500 V
1500 V
NotaNota
Nota : I f the pointer does not deflect check 10 A fuse
NotaNota
Decibelmeter Decibelmeter
Decibelmeter :
Decibelmeter Decibelmeter
Compare V2 > V1
V2
Gain = dB V2 reading - dB V1 reading
V1
Not workable in the first third of the scale and in 1500 V AC range
Direct dB reading - 10 to + 16 dB (5 V AC range)
(0 dB = 0.775 V 1 mW / 600 W )
Add+ 10 dBif 15 V AC range
+ 20 dBif 50 V AC range
+ 30 dBif150 V AC range
+ 40 dBif500 V AC range
SelectorSelector
Selector
SelectorSelector
positionposition
position
positionposition
5 V AC
15 V AC
50 V AC
150 V AC
500 V AC
500 V AC
ScaleScale
Scale
ScaleScale
5 red
150 black
50 black
150 black
50 black
150 black
Unit/FactorUnit/Factor
Unit/Factor
Unit/FactorUnit/Factor
V x 1
V : 10
V x 1
V x 1
V x 10
V x 10
30
MX 430B
3.3.5 mA DC Function :3.3.5 mA DC Function :
3.3.5 mA DC Function :
3.3.5 mA DC Function :3.3.5 mA DC Function :
Leads plugged into :
- COM and mA V / kW / W sockets (25 µA to 150 mA)
- COM and 1.5 A (or 15 A) sockets (1.5 A or 15 A ranges)
RangesRanges
Ranges
RangesRanges
25 µ A
150 µA
1.5 mA
15 mA
150 mA
1.5 A
15 A
NotaNota
Nota :If the pointer does not deflect :
NotaNota
1.5 A and 15 A ranges : check 10 A fuse
other ranges > check 0.16 A fuse
WarningWarning
Warning : >15 A DC measurement is limited to 5 minutes
WarningWarning
(10 A DC permanent)
> 3 A use leads with convenient wires
3.3.6. mA AC Function3.3.6. mA AC Function
3.3.6. mA AC Function
3.3.6. mA AC Function3.3.6. mA AC Function
Leads plugged into :
- COM and mA V / kW / W sockets (1.5 mA to 150 mA ranges)
- COM and 1.5 A (for 1.5 A) sockets (15 A for 15 A ranges)
Ranges Selector position Red scale Unit/FactorRanges Selector position Red scale Unit/Factor
Ranges Selector position Red scale Unit/Factor
Ranges Selector position Red scale Unit/FactorRanges Selector position Red scale Unit/Factor
SelectorSelector
Selector
SelectorSelector
positionposition
position
positionposition
50 mV DC
150 µ A D C
1.5 mA DC
15 mA DC
150 mA DC
150 mA DC
150 mA DC
BlackBlack
Black
BlackBlack
scalescale
scale
scalescale
50
150
150
150
150
150
150
Unit/FactorUnit/Factor
Unit/Factor
Unit/FactorUnit/Factor
µA : 2
µA x 1
mA : 100
mA : 10
mA x 1
A : 100
A : 10
1.5 mA
15 mA
150 mA
1.5 A
15 A
1.5 mA AC
15 mA AC
150 mA AC
150 mA AC
150 mA AC
15*
15
15
15
15
mA : 10
mA x 1
mA x 10
A : 10
A x 1
31
MX 430B
NotaNota
Nota :if the pointer does not deflect :
NotaNota
1.5 and 15 A ranges : check 10 A fuse
other ranges
* Warning * Warning
* Warning : 15 A AC measurement is limited to 5 minutes (10 A AC perma-
* Warning * Warning
nent) only if the waveform has a perfect sine shape. If not the true
RMS, equivalent to the "mean value" of the rectified signal, could
overflow the RMS limit and thus could deliver an undesirable
overheating.
Recall :Recall :
Recall : When measuring high current voltage for a long while, take out
Recall :Recall :
the multimeter out of its rubber shock absorber or carrying case.
> 3 A use leads with convenient wires.
3.4.4 Temperature probe -50°C to +150°C3.4.4 Temperature probe -50°C to +150°C
3.4.4 Temperature probe -50°C to +150°C
3.4.4 Temperature probe -50°C to +150°C3.4.4 Temperature probe -50°C to +150°C
(see HA1159 instruction book)(see HA1159 instruction book)
(see HA1159 instruction book)
(see HA1159 instruction book)(see HA1159 instruction book)
Use V DC ranges according to the probe sensitivity (1 or 10 mV/°C). Reverse
leads connection if negative temperatures are expected.
Probe sensitivityProbe sensitivity
Probe sensitivity
Multimeter rangeMultimeter range
Multimeter range
Multimeter rangeMultimeter range
150 mV DC
50 mV DC
Probe sensitivityProbe sensitivity
1 mV/°C
10 mV/°C
1 mV/°C
10 mV/°C
Temperature rangeTemperature range
Temperature range
Temperature rangeTemperature range
- 50°C to + 150°C
- 15°C to + 15°C
- 50°C to + 50°C
- 5°C to + 5°C
34
MX 430B
3.4.5 EHT probes3.4.5 EHT probes
3.4.5 EHT probes
3.4.5 EHT probes3.4.5 EHT probes
30 kV and 15 kV DC
Connect to - COM and V mA kW / W sockets
multimeter at 25 µ A DC (50 mV DC)
Read on black scale 150 (V x 200 or V x 100)
mA V k W /W
- COM
3.4.6 TV filter probe (see HA0902 instruction book)3.4.6 TV filter probe (see HA0902 instruction book)
3.4.6 TV filter probe (see HA0902 instruction book)
3.4.6 TV filter probe (see HA0902 instruction book)3.4.6 TV filter probe (see HA0902 instruction book)
Avoids VAC HF high peaks when the multimeter has been set to V DC 500 V
or 1500 V ranges
35
MX 430B
36
MX 430B
ANALOG MULTIMETERANALOG MULTIMETER
ANALOG MULTIMETER
ANALOG MULTIMETERANALOG MULTIMETER
MX 430 BMX 430 B
MX 430 B
GEBRAUCHSANWEISUNGGEBRAUCHSANWEISUNG
GEBRAUCHSANWEISUNG
GEBRAUCHSANWEISUNGGEBRAUCHSANWEISUNG
Nützliche Hinweise :Nützliche Hinweise :
Nützliche Hinweise :
Nützliche Hinweise :Nützliche Hinweise :
Dieses Multimeter entspricht voll und ganz den Sicherheitsvorschriften
gemäß NFC 42010, CEI 414, VDE 410.
Bei Beachtung der Vorschriften in der vorliegenden Gebrauchsanweisung
hat der Anwender des Gerätes vollen Schutz bei Gefahren. Bei
unsachgemässer Bedienung ist dieser Schutz jedoch nicht mehr
gewährleistet.
MESSBER.MESSBER.
MESSBER.
FUNKTIONENFUNKTIONEN
FUNKTIONEN
FUNKTIONENFUNKTIONEN
V AC
dB
I AC
MESSBER.MESSBER.
15 V AC
50 V AC
150 V AC
500 V AC
Bereiche
MX 430 BMX 430 B
FREQUENZGANGFREQUENZGANG
FREQUENZGANG
FREQUENZGANGFREQUENZGANG
5 V
15 V
50 V
150 V
500 V
1500 V
5 V AC
alle
FREQUENZENFREQUENZEN
FREQUENZEN
FREQUENZENFREQUENZEN
40-45 Hz / 65 Hz-100 kHz
40-45 Hz / 65 Hz-20 kHz
40-45 Hz / 65 Hz-5 kHz
65 Hz bis 1 kHz
65 Hz bis 500 Hz
65 Hz bis 500 Hz
40-45 Hz / 65 Hz-100 kHz
40-45 Hz / 65 Hz-20 kHz
40-45 Hz / 65 Hz-5 kHz
65 Hz bis 1 kHz
65 Hz bis 500 Hz
65 Hz bis 500 Hz
GENAUIGKEITGENAUIGKEIT
GENAUIGKEIT
GENAUIGKEITGENAUIGKEIT
± 4%
± 4%
± 4%
± 4%
± 5%
± 5%
± 1,5 dB
(von + 0 dB
bis + 11 dB)
± 5%
37
MX 430B
1 - EINFÜHRUNG1 - EINFÜHRUNG
1 - EINFÜHRUNG
1 - EINFÜHRUNG1 - EINFÜHRUNG
1.1 ALLGEMEINES1.1 ALLGEMEINES
1.1 ALLGEMEINES
1.1 ALLGEMEINES1.1 ALLGEMEINES
Dieses Analog-Multimeter mit einem Eingangswiderstand von 40 000 W /V ist
durch seine breit gefächerten Meßbereiche optimal für den Einsatz in
Elektronik und Elektrotechnik geeignet.
Funktionen und -Bereiche werden durch einen einzigen Drehschalter
angewählt. Die Isolationsspannung beträgt 3 kV. Metallteile können nicht
berührt werden.
Der mechanische Aufbau ist robust und das Gerät läßt sich einfach
transportieren. Eine aufklappbare Stütze kann das Gerät in eine bequeme
ablesbare Schrägelage bringen. Neben einer Gummimanschette und einer
Tragtasche ist eine Vielzahl von Zubehörgeräten erhältlich, die den
Einsatzbereich des Gerätes erweitern.
1.2 BESONDERHEITEN1.2 BESONDERHEITEN
1.2 BESONDERHEITEN
1.2 BESONDERHEITEN1.2 BESONDERHEITEN
Bei diesem ist auf sämtlichen Meßbereichen eine kurzzeitige Überlastung mit
220 V Wechselspannung ohne Beschädigung des Gerätes zulässig, lediglich
die Schmelzsicherungen sind gegebenenfalls zu ersetzen. Für die Strommeßbreiche bis < 15 mA, alle Ohmmeter-Beriche und die Gleichspannungsbereiche 50 und 150 mV wurde der Überlastsschutz durch eine neuartige
Schaltung mit nicht linearen Bauelementen realisiert (deswegen muß nach
einer überlastung einige Minuten gewartet werden, bis das Gerät wieder
betriebsbereit ist).
Sämtliche Spannungsbereiche sind gegen Überlastung mit Netzspannung
durch großzügig dimensionierte Bauelemente geschützt. In den Strommeßbereichen > 15 mA und darüber ist das Gerät durch Schmelzsicherungen
gesichert. Die Hauptsicherung mit hohem Trennvermögen von 10 A / 80 kA
befindet sich im "Common"-Eingang und ist also in allen Meßbereichen
wirksam.
38
MX 430B
Sämtliche Sicherungen sowie die Batterien sind auf der Geräterückseite gut
zugänglich untergebracht. Die Meßbuchsen sind zusätzlich isoliert und
vorgesehen für die Verwendung mit Sicherheitsmeßschnüren. Bei
Widerstandswerten bis 500 W ermöglicht eine lineare Skaleneinteilung die
präzise Messung niederohmiger Bauteile und Schaltungen.
1.3 ALLGEMEINE HINWEISE1.3 ALLGEMEINE HINWEISE
1.3 ALLGEMEINE HINWEISE
1.3 ALLGEMEINE HINWEISE1.3 ALLGEMEINE HINWEISE
Bei Beachtung der folgenden Hinweise lassen sich die häufigsten
Bedienungsfehler vermeiden :
11
1 - Wenn die Grössenordnung einer Meßgröße unbekannt ist,
11
muß stets der größte Meßbereich gewählt werden. Meßbereich
anschließend soweit herunterschalten bis der größte ablesbare
Zeigerausschlag erzielt wird.
2 2
2 - Vor jeder Messung prüfen, ob der Zeiger im Ruhestand auf der
2 2
Null der Skala steht. Nullpunkt gegebenenfalls mit der
mechanisch wirkende Justierschraube auf der Geräterückseite
nachstellen.
33
3 - In der Meßart "Ohmmeter" oder "Amperemeter" keine
33
Spannungen in das Gerät einspeisen.
44
4 - Bei den höchsten meßbaren Stromwerten sollte die Messung
44
nicht unnötig verlängert werden. Für Strommessungen über einen
längeren Zeitraum ist das Meßgerät aus der Gummimanschette
bzw. aus der Transporttasche herauszunehmen.
55
5 - Bei Messungen mit den Hochspannungstastköpfen ist darauf
55
zu achten, daß der Griff des Tastkopfes einwandfrei sauber ist ;
Schmutz und Staub können eine Oberflächenleitung bewirken.
Vor einer Messung in Meßart "Ohmmeter" mit dem Multimeter ist
die Leitfähigkeit zwischen dem Schutzring und den schwarzen
Bananensteckern zu überprüfen. Der gemessene Widerstand darf
10 W nicht übersteigen.
39
MX 430B
Die Messungen sind in sehr trockener Umgebung auf einer
isolierenden Unterlage durchzuführen.
Während der Messung ist mit der freien Hand oder jedem anderen
Körperteil ein Kontakt mit geerdeten Metallgegenständen zu
vermeiden.Soweit möglich ist die Messung hinter einem hochohmigen Widerstand durchzuführen, der bei Unfällen einen
hohen Spannungsabfall verursacht.
6 - Messung von nicht sinusförmigen Wechselspannungen6 - Messung von nicht sinusförmigen Wechselspannungen
6 - Messung von nicht sinusförmigen Wechselspannungen
6 - Messung von nicht sinusförmigen Wechselspannungen6 - Messung von nicht sinusförmigen Wechselspannungen
oder Strömen.oder Strömen.
oder Strömen.
oder Strömen.oder Strömen.
Das Multimeter ist für sinusförmige Wechselspannugen geeicht.
Bei Messung von nicht sinusförmigen Wechselspannungen wird
der "Mittelwert" angezeigt.
Der angezeigte Mittelwert kann vom Effektivwert der Spannung
erheblich abweichen. Im Zweifelsfalle ist diese Wechselspannung
mit einem Oszilloskop zu kontrollieren.
77
7 - Bei Verwendung der Stromanlegezangen zur Messung von
77
hohen Wechselströmen (Übersetzungsverhältnis 1 : 1000) darf
der Meßbereich nur nach Abnehmen der Anlegezange vom Leiter
umgeschaltet werden. Dadurch werden unzulässig hohe
Spannungsspitzen auf der Sekundärseite der Anlegezange
vermieden.
8 - Messung von Gleichsspannungen mit dem HF-Tastkopf mit8 - Messung von Gleichsspannungen mit dem HF-Tastkopf mit
8 - Messung von Gleichsspannungen mit dem HF-Tastkopf mit
8 - Messung von Gleichsspannungen mit dem HF-Tastkopf mit8 - Messung von Gleichsspannungen mit dem HF-Tastkopf mit
TV-FilterTV-Filter
TV-Filter
TV-FilterTV-Filter
Durch das eingebaute Filter in der Sonde werden impulsförmige
hohe Spannungsspitzen integriert (z. B. in der Zeilenablenkstufe
in der Fernsehempfängern)
ACHTUNG :ACHTUNG :
ACHTUNG :
ACHTUNG :ACHTUNG :
Es ist gefährlich, die Messung direkt an der Anode der Zeilenablenkröhre vorzunehmen. Dort können Spannungspitzen auftreten,die das Meßgerät evtl. beschädigen. Als Meßpunkte werden
empfohlen : Gitterspannung an der Zeilenablenkröhre oder
Basis des Zeilentransformators an den Klemmen des BoosterKondensators.
40
MX 430B
2 - TECHNISCHE DATEN2 - TECHNISCHE DATEN
2 - TECHNISCHE DATEN
2 - TECHNISCHE DATEN2 - TECHNISCHE DATEN
2.1. GLEICHSPANNUNGEN2.1. GLEICHSPANNUNGEN
2.1. GLEICHSPANNUNGEN
2.1. GLEICHSPANNUNGEN2.1. GLEICHSPANNUNGEN
Meßbereiche :Meßbereiche :
Meßbereiche : 50 - 150 mV
Meßbereiche :Meßbereiche :
0,5 - 1,5 - 5 - 15 - 50 - 150 - 500 V
Stromaufnahme : 25 µA
1500 V über zusätzliche Eingangsklemme1500 V über zusätzliche Eingangsklemme
1500 V über zusätzliche Eingangsklemme
1500 V über zusätzliche Eingangsklemme1500 V über zusätzliche Eingangsklemme
Genauigkeitsklasse : 1,5 (3 im Meßbereich 1500 V)
Innenwiderstand : 40 kW / V (10 k W im Meßbereich 1500 V)
Meßbereichserweiterungen bis 15 kV bzw. 30 kVMeßbereichserweiterungen bis 15 kV bzw. 30 kV
Meßbereichserweiterungen bis 15 kV bzw. 30 kV
Meßbereichserweiterungen bis 15 kV bzw. 30 kVMeßbereichserweiterungen bis 15 kV bzw. 30 kV
(siehe Hochspannungstastköpfe)
2.2. WECHSELSPANNUNGEN2.2. WECHSELSPANNUNGEN
2.2. WECHSELSPANNUNGEN
2.2. WECHSELSPANNUNGEN2.2. WECHSELSPANNUNGEN
Meßbereiche Meßbereiche
Meßbereiche :
Meßbereiche Meßbereiche
5 - 15 - 50 - 150 - 500 V
Stromaufnahme : 250 µA
1500 V über zusätzliche Eingangsklemme1500 V über zusätzliche Eingangsklemme
1500 V über zusätzliche Eingangsklemme
1500 V über zusätzliche Eingangsklemme1500 V über zusätzliche Eingangsklemme
Genauigkeitsklasse : 2,5 (4 auf Bereich 1500 V) bei 45-65 Hz
Innenwiderstand : 4 kW /V
Pegelmessungen in dBPegelmessungen in dB
Pegelmessungen in dB :
Pegelmessungen in dBPegelmessungen in dB
- 10 bis + 56 dB (mit 0 dB = 1 mW/600 W )
Direkt ablesbare Skala von - 10 bis + 16 dB
FrequenzgangFrequenzgang
Frequenzgang : Siehe Tabelle Seite 37
FrequenzgangFrequenzgang
2.3. GLEICHSTRÖME2.3. GLEICHSTRÖME
2.3. GLEICHSTRÖME
2.3. GLEICHSTRÖME2.3. GLEICHSTRÖME
MeßbereicheMeßbereiche
Meßbereiche :
MeßbereicheMeßbereiche
25 µ A (in dem Meßbereich 50 mV und den anderen GleichspannungsMeßbereichen)
150 µ A - 1,5 - 15 - 150 mA
1.5 und 15 A über zusätzliche Eingangsklemmen1.5 und 15 A über zusätzliche Eingangsklemmen
1.5 und 15 A über zusätzliche Eingangsklemmen
1.5 und 15 A über zusätzliche Eingangsklemmen1.5 und 15 A über zusätzliche Eingangsklemmen
Genauigkeitsklasse : 1,5
Spannungsabfall :
Meßbereichserweiterungen durch externe Shunts 100 mV und 300 mV:Meßbereichserweiterungen durch externe Shunts 100 mV und 300 mV:
Meßbereichserweiterungen durch externe Shunts 100 mV und 300 mV:
Meßbereichserweiterungen durch externe Shunts 100 mV und 300 mV:Meßbereichserweiterungen durch externe Shunts 100 mV und 300 mV:
15 A bis 500 A15 A bis 500 A
15 A bis 500 A
15 A bis 500 A15 A bis 500 A
< 1,2
41
MX 430B
2.4. WECHSELSTRÖME2.4. WECHSELSTRÖME
2.4. WECHSELSTRÖME
2.4. WECHSELSTRÖME2.4. WECHSELSTRÖME
MeßbereicheMeßbereiche
Meßbereiche :
MeßbereicheMeßbereiche
1,5 - 15 - 150 mA
1,5 und 15 A über zusätzliche Eingangsklemmen
Genauigkeitsklasse : 2,5 bei 45 - 65 Hz
Spannungsabfall :
Meßbereichserweiterungen durch Stromwandlerzangen
1 : 1000 : 250 A - 1000 A
Achtung Achtung
Achtung : Starke Gleich- und Wechselströme im Bereich von ca. 15 A
Achtung Achtung
2.5. WIDERSTANDSMESSUNG2.5. WIDERSTANDSMESSUNG
2.5. WIDERSTANDSMESSUNG
2.5. WIDERSTANDSMESSUNG2.5. WIDERSTANDSMESSUNG
Lineare Skalenleitung : 50 W - 500 W
Genauigkeitsklasse : 2
Als interne Stromquelle wird bei dieser Meßart eine 9 V-Batterie IEC 6F22
eingesetzt, die einen Meßstrom von 3 mA abgibt. Bei offener Schaltung
schlägt der Zeiger voll bis zum rechten Skalenende aus, d. h. daß die
Stromquelle ihren vollen Meßstrom abgibt.
Soweit die Meßbereiche 50 W und 500 W nicht benutzt werden, den Drehschalter nicht in diese Stellung drehen, da sonst die Batterie unnötigt entleert
wird.
kk
-Meßber. mit umgekehrter Skalenleitung : k-Meßber. mit umgekehrter Skalenleitung : k
kW
-Meßber. mit umgekehrter Skalenleitung : kW
kk
-Meßber. mit umgekehrter Skalenleitung : k-Meßber. mit umgekehrter Skalenleitung : k
< 1.2 V
dürfen nur während höchstens 5 Minuten gemessen werden.
(Ströme bis 10 A können dauernd gemessen werden).
x 1 kx 1 k
x 100 x 100
x 1 kW
x 100
x 1 kx 1 k
x 100 x 100
Schalter-Schalter-
Schalter-
Schalter-Schalter-
stellungstellung
stellung
stellungstellung
kW x 1
kW x 100
Genauigkeitsklasse : Skalenende ± 10 %
Meß-Meß-
Meß-
Meß-Meß-
umfangumfang
umfang
umfangumfang
0.1 k W -200 kW
10 k W -20 mW
Mittel-Mittel-
Mittel-
Mittel-Mittel-
stellungstellung
stellung
stellungstellung
2,5 k W
250 kW
42
max.max.
max.
max.max.
StromStrom
Strom
StromStrom
0.66 mA
40 µ A
Strom-Strom-
Strom-
Strom-Strom-
quellequelle
quelle
quellequelle
1.5 V IEC R6
9 V IEC 6F22
MX 430B
2.6 MESSUNG DER DURCHLASSPANNUNG BEI HALBLEITERN2.6 MESSUNG DER DURCHLASSPANNUNG BEI HALBLEITERN
2.6 MESSUNG DER DURCHLASSPANNUNG BEI HALBLEITERN
2.6 MESSUNG DER DURCHLASSPANNUNG BEI HALBLEITERN2.6 MESSUNG DER DURCHLASSPANNUNG BEI HALBLEITERN
Schalterstellung : 500 W lineare Skala
Meßstrom : 3 mA
Direkte Ablesung bis 1,5 V auf der schwarzen Skala 0 - 150
(Durchlaßspannung = Skalenwert : 100)
Das mit unterbrochener Abschirmung eingebaute Spannbandmeßwerk ist
mit 2 Dioden geschützt.
Zulässige Überlast in allen Bereichen : 220 V Wechselstrom Überlastschutz
in allen Bereichen durch Schmelzsicherung 10 A mit hohem Trennvermögen
(500 V / 80 kA) im Common-Eingang.
Schmelzsicherung 0,16 A halbträge für Strommeßbereiche 15 mA und
darüber.
2.9 ABMESSUNGEN UND GEWICHT2.9 ABMESSUNGEN UND GEWICHT
2.9 ABMESSUNGEN UND GEWICHT
2.9 ABMESSUNGEN UND GEWICHT2.9 ABMESSUNGEN UND GEWICHT
Breite x Höhe x TiefeBreite x Höhe x Tiefe
Breite x Höhe x Tiefe : 110 mm x 45 mm x 185 mm
Breite x Höhe x TiefeBreite x Höhe x Tiefe
Gewicht : Gewicht :
Gewicht : ca. 0,5 kg
Gewicht : Gewicht :
43
MX 430B
2.10 ZUBEHÖRTEILE2.10 ZUBEHÖRTEILE
2.10 ZUBEHÖRTEILE
2.10 ZUBEHÖRTEILE2.10 ZUBEHÖRTEILE
2.10.1 Mit dem Multimeter geliefertes Zubehör2.10.1 Mit dem Multimeter geliefertes Zubehör
2.10.1 Mit dem Multimeter geliefertes Zubehör
2.10.1 Mit dem Multimeter geliefertes Zubehör2.10.1 Mit dem Multimeter geliefertes Zubehör
1 Schmelzsicherung 0,16 A halbträgeAA0411
1 Schmelzsicherung 10 A flink 500 V m.h.T. AA2346
1 Satz SicherheitsmeßschnüreAG0328
1 Batterie 9 V 6F22 IECAL0020
1 Batterie 1,5 V R6 IECAL0008
2.9.2. Auf Wunsch lieferbares Zubehör2.9.2. Auf Wunsch lieferbares Zubehör
2.9.2. Auf Wunsch lieferbares Zubehör
2.9.2. Auf Wunsch lieferbares Zubehör2.9.2. Auf Wunsch lieferbares Zubehör
HF-Tastkopf mit TV-FilterHA0902
Satz Meßschnüre mit KlemmspitzenHA0932
TragtascheAE0181
GummimanschetteMC0136
ANMERKUNGEN :ANMERKUNGEN :
ANMERKUNGEN :
ANMERKUNGEN :ANMERKUNGEN :
1) Durch Benutzung des Zwischensteckers HA0709 kann die
netzstromaufnahme eines Gerätes ohne Unterbrechung der Netzversorgung
gemessen werden (nicht für Schuko-Dosen geeignet)
2) Der HF-Tastkopf mit TV-Filter HA0902 unterdrückt HFSpannungsspitzen bei Gleichspannungsmessungen
44
MX 430B
3 - BENUTZUNG UND NACHEICHUNG3 - BENUTZUNG UND NACHEICHUNG
3 - BENUTZUNG UND NACHEICHUNG
3 - BENUTZUNG UND NACHEICHUNG3 - BENUTZUNG UND NACHEICHUNG
3.1 EINSETZEN DER BATTERIEN3.1 EINSETZEN DER BATTERIEN
3.1 EINSETZEN DER BATTERIEN
3.1 EINSETZEN DER BATTERIEN3.1 EINSETZEN DER BATTERIEN
Galvanometer
Nullpunktabgleich
0 - Gerätestütze auf der Rückseite
des Gerätes aufklappen.
1 - Die seitlichen Teile der Stütze
zusammen drücken.
2 - Stütze herausnehmen.
3 - 4 - Deckel dann in Pfeilrichtung herausschieben.
AchtungAchtung
Achtung : Vor Öffnung des Batteriefaches die Meßschnüre herausziehen.
AchtungAchtung
Deckel in Pfeilrichtung mittels der Klappstütze auf geschoben. Anschl. gemäß
Polaritätsangaben eine Batterie 9 V IEC 6F22 und eine Batterie 1,5 V IEC R6
einsetzen.
45
MX 430B
3.2 EINSETZEN DER SICHERUNGEN3.2 EINSETZEN DER SICHERUNGEN
3.2 EINSETZEN DER SICHERUNGEN
3.2 EINSETZEN DER SICHERUNGEN3.2 EINSETZEN DER SICHERUNGEN
Die Schmelzsicherungen jeweils durch genau den selben Typ ersetzen.
AchtungAchtung
Achtung : Bei Sicherungen des falschen Typs oder mit falscher
AchtungAchtung
Nennstromstärke ist der Überlastschutz des Gerätes nicht mehr
gewährleistet.
3.3 BENUTZUNGSHINWEISE3.3 BENUTZUNGSHINWEISE
3.3 BENUTZUNGSHINWEISE
3.3 BENUTZUNGSHINWEISE3.3 BENUTZUNGSHINWEISE
3.3.1 Nacheichung3.3.1 Nacheichung
3.3.1 Nacheichung
3.3.1 Nacheichung3.3.1 Nacheichung
Eine Nacheichung soll nur nach längerer Lagerung (über 1 Jahr) oder nach
einer Reparatur durch den Benutzer (ausserhalb der Garantiezeit
vorgenommen werden).
AnmerkungAnmerkung
Anmerkung : Öffnen des Multimeters durch Lösen der vier Schrauben auf der
AnmerkungAnmerkung
Geräterückseite (2 Schrauben befinden sich im Batteriefach). Vor der
Eichung Nullpunktjustierung des Zeigers prüfen !
Mit Hilfe einer Eichquelle deren Genauigkeitsklasse :Mit Hilfe einer Eichquelle deren Genauigkeitsklasse :
Mit Hilfe einer Eichquelle deren Genauigkeitsklasse :
Mit Hilfe einer Eichquelle deren Genauigkeitsklasse :Mit Hilfe einer Eichquelle deren Genauigkeitsklasse :
- Mindestens 0,5 ist : 50 mV DC Bereich 50 mV (25 µA DC) anlegen. Den
Vollauschlag mit R33 abgleichen.
- Danach 150 µA DC in den Bereich 150 µA DC einspeisen. Den Vollausschlag mit R34 nachjustieren.
- 25 µA DC in den Bereich 50 mV DC (25 µA DC) einspeisen und falls
erforderlich mit R34 nachjustieren, soweit die Abweichung mehr als 0,8 %
beträgt.
- Im Meßbereich 5 V Wechselspannung 250 µA Wechselstrom in das Gerät
einspeisen. Mit R35 Zeiger auf Endausschlag einstellen.
- Im Meßbereich 1,5 mA Wechselstrom 1,5 mA Wechselstrom einspeisen. Mit
R36 Zeiger auf Endausschlag einstellen.
- Im Meßbereich 50
Buchsen - COM und mA k
einstellen.
Anzeigegenauigkeit in den anderen Meßbereichen des Multimeters anschl.
ebenfalls prüfen.
WW
W mit linearer Skala einen Eichwiderstand 50
WW
WW
WW
W/
W anschließen. Mit R37 Zeiger auf Endausschlag
WW
WW
WW
W an
WW
46
MX 430B
3.3.2 Betriebsart 3.3.2 Betriebsart
3.3.2 Betriebsart
3.3.2 Betriebsart 3.3.2 Betriebsart
1) 1)
1) Meßschnüre an Eingangsbuchsen - COM und mA V k
1) 1)
2) 2)
2) Darauf achten, daß der zu messende Widerstand nicht unter Spannung
2) 2)
steht.
3) Betriebsart Ohmmeter mit direkter linearer Skala (Überlastschutz gegen
220 V Netzspannung durch Thermistor - Varistor - Schaltung)
DrehschalterstellungDrehschalterstellung
Drehschalterstellung
DrehschalterstellungDrehschalterstellung
Meßstrom von 3 mA auch zur Messung der Durchlaßspannung vonMeßstrom von 3 mA auch zur Messung der Durchlaßspannung von
Meßstrom von 3 mA auch zur Messung der Durchlaßspannung von
Meßstrom von 3 mA auch zur Messung der Durchlaßspannung vonMeßstrom von 3 mA auch zur Messung der Durchlaßspannung von
Halbleitern (Anschluß : COMHalbleitern (Anschluß : COM
Halbleitern (Anschluß : COM
Halbleitern (Anschluß : COMHalbleitern (Anschluß : COM
zu 1,5 V wird auf der schwarzen Skala 150 in V : 100 abgelesen.zu 1,5 V wird auf der schwarzen Skala 150 in V : 100 abgelesen.
zu 1,5 V wird auf der schwarzen Skala 150 in V : 100 abgelesen.
zu 1,5 V wird auf der schwarzen Skala 150 in V : 100 abgelesen.zu 1,5 V wird auf der schwarzen Skala 150 in V : 100 abgelesen.
Anmerkung :Anmerkung :
Anmerkung :Der Nullpunkt der linearen W -Skala befindet sich links,
Anmerkung :Anmerkung :
Achtung :Achtung :
Achtung :Nach Benutzung der Meßbereiche 50 W bzw. 500 W
Achtung :Achtung :
4)4)
4) Betriebsart Ohmmeter mit umgekehrter logarithmischer Skala
4)4)
Zeiger auf Null der grünen Skala stellen durch Kurzschließen der Meßspitzen
und Drehen des Knopfes für W -Nullabgleich
DrehschalterstellungDrehschalterstellung
Drehschalterstellung
DrehschalterstellungDrehschalterstellung
WW
W
WW
AnzeigeskalaAnzeigeskala
Anzeigeskala
AnzeigeskalaAnzeigeskala
WW
50
W
WW
WW
500
W
WW
Der lineare Ohmmeter-Meßbereich 500 Der lineare Ohmmeter-Meßbereich 500
Der lineare Ohmmeter-Meßbereich 500
Der lineare Ohmmeter-Meßbereich 500 Der lineare Ohmmeter-Meßbereich 500
für steigende Widerstands- bzw. Durchlaßspannungswerte (50 W - 500 W ) schlägt der Zeiger nach recht aus.
Bei offener Schaltung oder R µ geht der Zeiger auf
Endausschlag.
Drehschalter wieder auf einen beliebigen anderen
Meßbereich stellen !
kW x 1
kW x 10
50 schwarz
50 schwarz
kk
WW
/ /
W W
). Die Durchlaßspannung bis ). Die Durchlaßspannung bis
k
W
/
W
). Die Durchlaßspannung bis
kk
WW
/ /
W W
). Die Durchlaßspannung bis ). Die Durchlaßspannung bis
AnzeigeskalaAnzeigeskala
Anzeigeskala
AnzeigeskalaAnzeigeskala
kW grün
kW grün
WW
WW
W/
W anschließen
WW
WW
EinheitEinheit
Einheit
EinheitEinheit
WW
W x 1
WW
WW
W x 10
WW
WW
dient mit einem dient mit einem
W
dient mit einem
WW
dient mit einem dient mit einem
MeßumfangMeßumfang
Meßumfang
MeßumfangMeßumfang
0,1 k W bis 200 k W
10 k W bis 20 M W
5) Falls der Zeiger nicht ausschlägt, Sicherung 10 A prüfen !
47
MX 430B
3.3.3 Betriebsart V DC3.3.3 Betriebsart V DC
3.3.3 Betriebsart V DC
3.3.3 Betriebsart V DC3.3.3 Betriebsart V DC
Meßschnüre an folgende Buchsen anschließen :
- COM und mA V k
- COM und 1500 V für den Meßbereich 1500 V
MeßbereichMeßbereich
Meßbereich
MeßbereichMeßbereich
50 mV
150 mV
0,5 V
1,5 V
5 V
15 V
50 V
150 V
500 V
1500 V
Anmerkung : Anmerkung :
Anmerkung : Falls der Zeiger nicht ausschlägt, Sicherung 10 A prüfen !
Anmerkung : Anmerkung :
3.3.4 Betriebsart V AC3.3.4 Betriebsart V AC
3.3.4 Betriebsart V AC
3.3.4 Betriebsart V AC3.3.4 Betriebsart V AC
Meßschnüre an folgenden Buchsen anschließen :
- COM und mA V k
- COM und 1500 V für den Meßbereich 1500 V
MeßbereichMeßbereich
Meßbereich
MeßbereichMeßbereich
5 V
15 V
50 V
150 V
500 V
1500 V
WW
W W
W
W für die Meßbereiche 50 mV bis 500 V
WW
W W
Meßbereichs-Meßbereichs-
Meßbereichs-
Meßbereichs-Meßbereichs-
schalter aufschalter auf
schalter auf
schalter aufschalter auf
50 mV DC
150 mV DC
0,5 V DC
1,5 V DC
5 V DC
15 V DC
50 V DC
150 V DC
500 V DC
500 V DC
WW
WW
W
W für die Meßbereiche 5 bis 500 V
WW
WW
Meßbereichs-Meßbereichs-
Meßbereichs-
Meßbereichs-Meßbereichs-
schalterschalter
schalter
schalterschalter
5 V AC
15 V AC
50 V AC
150 V AC
500 V AC
500 V AC
Anzeige-Anzeige-
Anzeige-
Anzeige-Anzeige-
skalaskala
skala
skalaskala
50 schwarz
150 schwarz
50 schwarz
150 schwarz
50 schwarz
150 schwarz
50 schwarz
150 schwarz
50 schwarz
150 schwarz
AnzeigeAnzeige
Anzeige
AnzeigeAnzeige
-skala-skala
-skala
-skala-skala
5 schwarz
150 schwarz
50 schwarz
150 schwarz
50 schwarz
150 schwarz
Ablesung inAblesung in
Ablesung in
Ablesung inAblesung in
Einheit/FaktorEinheit/Faktor
Einheit/Faktor
Einheit/FaktorEinheit/Faktor
mV x 1
mV x 1
mV x 10
V : 100
V : 10
V : 10
V x 1
V x 1
V x 10
V x 10
Ablesung inAblesung in
Ablesung in
Ablesung inAblesung in
Einheit/FaktorEinheit/Faktor
Einheit/Faktor
Einheit/FaktorEinheit/Faktor
V x 1
V : 10
V x 1
V x 1
V x 10
V x 10
AnmerkungAnmerkung
Anmerkung : Falls der Zeiger nicht ausschlägt, Sicherung 10 A prüfen !
AnmerkungAnmerkung
48
MX 430B
Pegelvergleichsmessung in Dezibel :Pegelvergleichsmessung in Dezibel :
Pegelvergleichsmessung in Dezibel :
Pegelvergleichsmessung in Dezibel :Pegelvergleichsmessung in Dezibel :
- Messung von zwei Spannungen V1 und V2 mit V2 > V1
- Gewinn V2 / V1 = Anzeige V2 in dB - Anzeige V1 in dB
- Messung in dem ersten Drittel der Skala und auf Meßbereich
1500 V AC nicht verwetbar
Direkt ablesbarer Skalenumfang (Meßbereich 5 V AC) :
- 10 bis + 16 dB (0 dB = 0,775 V 1 mW/600
Anzeige +10 dB im Meßbereich15 V AC
Anzeige +20 dB im Meßbereich50 V AC
Anzeige +30 dB im Meßbereich150 V AC
Anzeige +40 dB im Meßbereich500 V AC
Anmerkung : Falls in den Meßbereichen 1,5 A und 15 A der Zeiger nicht
Anmerkung : Anmerkung :
ausschlägt, Sicherung 10 A prüfen ! In den anderen Meßbereichen
> 15 mA, Sicherung 0,16 A prüfen.
AchtungAchtung
*
Achtung : Ströme mit ca. 15 A dürfen während höchstens 5 Minuten
AchtungAchtung
gemessen werden. > 3 A : Verwendung von Meßkabeln
ensprechenden Querschnittes.
3.3.6 Betriebsart mA AC3.3.6 Betriebsart mA AC
3.3.6 Betriebsart mA AC
3.3.6 Betriebsart mA AC3.3.6 Betriebsart mA AC
Meßschnüre an folgenden Buchsen anschließen :
WW
- COM und mA k
- COM und 1,5 A für en Meßbreich 1,5 A (15 A für den Meßbereich 15 A).
WW
W/
W für die Meßbereiche 1,5 mA bis 150 mA
WW
WW
MeßbereichMeßbereich
Meßbereich
MeßbereichMeßbereich
1,5 mA
15 mA
150 mA
1,5 A
10 A*
AnmerkungAnmerkung
Anmerkung : Falls in den Meßbereichen 1,5 A und 15 A der Zeiger nicht
AnmerkungAnmerkung
ausschlägt, Sicherung 10 A prüfen. In den anderen Meßbereichen
> 15 mA, Sicherung 0,16 A prüfen. Diese Angaben setzen voraus,
daß es sich um sinusförmige Ströme handelt. Bei nicht sinusförmigen Signalen kann der wirkliche Effektivwert eines angezeigten Mittelwert von 10 A, z. B. weit höher liegen, und zu einer
unerwünschten Erwärmung führen.
Meßbereichs-Meßbereichs-
Meßbereichs-
Meßbereichs-Meßbereichs-
schalter aufschalter auf
schalter auf
schalter aufschalter auf
1,5 mA AC
15 mA AC
150 mA AC
150 mA AC
150 mA AC
Anzeige-Anzeige-
Anzeige-
Anzeige-Anzeige-
skalaskala
skala
skalaskala
15 rot
15 rot
15 rot
15 rot
15 rot
Ablesung inAblesung in
Ablesung in
Ablesung inAblesung in
Einheit/FaktorEinheit/Faktor
Einheit/Faktor
Einheit/FaktorEinheit/Faktor
mA : 10
mA x 1
mA x 10
A : 10
A x 1
50
MX 430B
Zur BeachtungZur Beachtung
Zur Beachtung : Bei Strommessungen über einen längeren Zeitraum ist
Zur BeachtungZur Beachtung
das Meßgerät aus der Gummimanschette bzw. aus der Transporttasche herauszunehmen.
*Achtung : *Achtung :
*Achtung : Ströme mit ca. 15 A dürfen während höchstens 5 Minuten
*Achtung : *Achtung :
gemessen werden. Ströme bis 10 A können daurend gemesen
werden. > 3 A : Verwendung von Meßkabeln entsprechenden
Querschnittes.
3.4 BENUTZUNG DER ZUBEHÖRTEILE3.4 BENUTZUNG DER ZUBEHÖRTEILE
3.4 BENUTZUNG DER ZUBEHÖRTEILE
3.4 BENUTZUNG DER ZUBEHÖRTEILE3.4 BENUTZUNG DER ZUBEHÖRTEILE
3.4.1 Shunts 50 mV3.4.1 Shunts 50 mV
3.4.1 Shunts 50 mV
3.4.1 Shunts 50 mV3.4.1 Shunts 50 mV
Multimeter auf
Meßbereich 50 mV DC
Shunts 50 mVShunts 50 mV
Shunts 50 mV
Shunts 50 mVShunts 50 mV
50 A
100 A
500 A
Ablesung auf SkalaAblesung auf Skala
Ablesung auf Skala
Ablesung auf SkalaAblesung auf Skala
50 schwarz
50 schwarz
50 schwarz
Ablesung inAblesung in
Ablesung in
Ablesung inAblesung in
Einheit/FaktorEinheit/Faktor
Einheit/Faktor
Einheit/FaktorEinheit/Faktor
A x 1
A x 2
A x 10
51
MX 430B
3.4.2 Zwischenstecker3.4.2 Zwischenstecker
3.4.2 Zwischenstecker
3.4.2 Zwischenstecker3.4.2 Zwischenstecker
Multimeter Funktion mA
Am Netz anschließen
Netzspannung
Netzstromversorgung (auf der Rückseite)
Durch Drücken des Tastknopfes wird die Stromaufnahme im mA-Meßbereich
des Multimeters angezeigt (Unterbrechung eines Netzleiters zur Messung in
Reihe von Strömen bis zur 10 A). Durch Verwendung diese Zwischesteckers
muß zur schnellen messung der Stromaufnahme eine Schaltung oder ein
kabel nicht mehr geöffnet werden.
3.4.3 Stromwandlerzange3.4.3 Stromwandlerzange
3.4.3 Stromwandlerzange
3.4.3 Stromwandlerzange3.4.3 Stromwandlerzange
Am Multimeter
Betriebsart mA AC
BB
B
BB
AA
A - Stromwandlerzange 250 A - Meßbereich 150 mA AC einstellen. Ablesung
AA
bis Teilstrich 15 (x 10) der roten Skala 15
BB
B - Stromwandlerzange 1000 A - Meßbereich 1,5 A AC einstellen. Ablesung
BB
bis Teilstrich 10 (x 100) der roten Skala 15
AA
A
AA
einstellen
52
MX 430B
3.4.4 Temperaturfühler - 50°C bis + 150°C3.4.4 Temperaturfühler - 50°C bis + 150°C
3.4.4 Temperaturfühler - 50°C bis + 150°C
3.4.4 Temperaturfühler - 50°C bis + 150°C3.4.4 Temperaturfühler - 50°C bis + 150°C
Bereiche V DC mit einer Empfindlichkeit entsprechend der des Fühlers
1 mV/°C oder 10 mV/°C (bei negativen Temperaturen ist der Fühler
umzupolen).