Glass Door Merchandisers
Instruction Manual
*
Version 3
3115 Pepper Mill Court, Mississauga, ON, L5L 4X5 |
1-800-465-0234 |
1889 Maryland Avenue, Niagara Falls, NY, 14305 |
www.omcan.com |
Table of Contents
Model G1.2YBM2F / Model G258BMF / Model G368BMF
Model D648BM2F / Model D768BM2F
Section |
Page |
Installation -------------------------------------------------------------------------------------------- |
3 |
Safety -------------------------------------------------------------------------------------------------- |
3 |
Maintenance ------------------------------------------------------------------------------------- |
3 - 4 |
Troubleshooting ------------------------------------------------------------------------------------- |
4 |
French Instructions ----------------------------------------------------------------------------- |
5 - 8 |
Controller Instructions ----------------------------------------------------------------------- |
9 - 11 |
Parts Breakdown ---------------------------------------------------------------------------- |
12 - 21 |
Electrical Schematics ---------------------------------------------------------------------- |
22 - 24 |
Warranty Registration ---------------------------------------------------------------------------- |
25 |
Installation
IMPORTANT!!!PLEASE READ BEFORE INSTALLATION
•The refrigeration system operates most efficiently when installed in an area with cool, dry air circulation.
•There must be at least 6 inches of clearance on both sides and the back of the cabinet.
•Select a location away from the heat and moisture generating equipment such as stoves, ovens, etc.
•Avoid direct sun rays.
•Be sure that the floor where you intend to install that unit is strong and level enough to support the total weight of the unit and its contents.
•To minimize shock and fire hazards, be sure that the unit is properly grounded. For your safety and protection, all units are equipped with a special three-prong grounding plug on the service cord.
•All units are designed for indoor use. Outdoor use may cause significant damage to the unit.
Safety
•To minimize shock and fire hazards, be sure not to overload the outlet.
•To minimize electric shock and malfunction, do not spray the unit with water.
•To minimize fire hazards, do not use flammable spray products near the unit
•After unplugging the unit, wait at least 6 minutes before re-plugging it. It may cause compressor failure if plugged in before 6 minutes waiting period.
•Cautions for cleaning:
-Unplug the power cord before cleaning.
-Do not unplug-plug the power cord with wet hands.
-Do not use an abrasive cleaners, solvents or polishing agents on plastic parts. Doing so might cause cracking or discoloring.
•When it is not in use:
-Unplug the power cord.
-Wipe inside with dry cloth, and you may leave the door slightly open to eliminate moisture and odor.
Maintenance
•When loading the unit:
-Be careful not to block the air duct located at the back and the fan on the ceiling of the unit with contents.
-Blocking the air flow may cause decrease in performance.
-For the best performance, maintain at least 4 inches of clearance between the contents and the air duct.
•Set the shelves that come with the unit to fit your needs.
•Temperature controller:
-The controller is located at the right, front corner of the ceiling, or on the front bottom panel
-To adjust temperature please refer to the manual of temperature controller
•Do not leave the unit door open for long period of time. For the most efficient operation, close the door
3
Maintenance
immediately after the use.
Troubleshooting
SYMPTOMS |
POSSIBLE CAUSE |
Compressor will not start |
• Check if the power cord has been plugged in. |
|
• Check for blown fuse. |
Poor Performance |
• Move the unit from direct sun light, and avoid |
|
installing heating devices near the unit. |
|
• Install the unit in a well ventilated place with |
|
minimum of 6” clearance in the back. |
|
• Check the condenser, and clean if heavy dust is |
|
collected. |
|
• Check to see if contents are blocking the air duct. |
|
• Check to see if refrigerant charge is low. |
|
• Make sure the door is completely closed. |
No Interior Light |
• Turn off the light switch and turn it on again. |
|
• Make sure the light is correctly inserted into the |
|
sockets. |
|
• Check the light, and replace it if blown. |
Unit Noisy |
• Make sure to install the unit on level surface. |
|
• Make sure to maintain the minimum clearance of |
|
6” from the wall. |
|
• Check for the loose parts or mounting. |
|
• Make sure the tubing is free from any contact to |
|
avoid tubing rattle. |
Condensation on Cabinet and/or Floor |
• Reduce the relatively humidity in the area where |
|
the unit is installed. |
|
• Gasket on door or head section is not sealing |
|
properly. Repair or replace gasket as necessary. |
For service call 1-800-465-0234.