Mersen, formerly Ferraz Shawmut A4BY Catalog Page

AMP-TRAP
®
A4BY CLASS L
COUNT ON THE HIGH INTERRUPTING RATING OF OUR most widely-used CLASS L FUSE
When it comes to protecting service entrance equipment, feeder circuits, and circuit breakers, A4BY fuses have been the industry’s favorite. The A4BY is a 100% rated device and may be applied at continuous currents up to its ampere rating. A 4-second minimum time delay at 500% rating allows the A4BY to pass normal current surges and to coordinate with ground fault relays.
Features/ Benefits
B
HIGHLIGHTS:
Current-Limiting
4-Second Time Delay
DC Ratings
Uniform Characteristics
in all Ampere Ratings
APPLICATIONS:
Mains, Feeders
Circuit Breakers
Panelboards
Switchboards
Metering Centers
Unique dimensions prevent replacement by other
fuse classes Blade stamped catalog numbers for permanent
identification Glass melamine body and plated terminals
provide superior reliability in harsh environments
Ratings
AC: 200 to 6,000A
600VAC,200kA I.R.
DC: 200 to 2500A
300VDC, 100kA I.R.
Approvals
UL Listed to Standard
248-10 (601-6000A) File E2137
CSA Certified to
Standard C22.2 No. 248.10 (601-6000A)
Ferraz Shawmut Certified
for DC per UL248 (601-6000A)
Indicators
Optional built-in fuse indicators (-TI) are available. Consult factory.
B 17
AMP-TRAP
®
CLASS L FUSES A4BY
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG
RATING NUMBER RATING NUMBER RATING NUMBER
200 A4BY200 801 A4BY801 2000 A4BY2000 250 A4BY250 900 A4BY900 2001 A4BY2001 300 A4BY300 1000 A4BY1000 2200 A4BY2200 350 A4BY350 1100 A4BY1100 2500 A4BY2500 400 A4BY400 1200 A4BY1200 3000 A4BY3000 450 A4BY450 1201 A4BY1201 3001 A4BY3001 500 A4BY500 1350 A4BY1350 3500 A4BY3500 600 A4BY600 1400 A4BY1400 4000 A4BY4000 601 A4BY601 1500 A4BY1500 4001 A4BY4001 650 A4BY650 1600 A4BY1600 4500 A4BY4500 700 A4BY700 1601 A4BY1601 5000 A4BY5000 750 A4BY750 1800 A4BY1800 6000 A4BY6000 800 A4BY800
2001-3000A
3001-4000A
200-800A
801-2000A
Dimensions
AMPERE A B C D E
RATING In. mm In. mm In. mm In. mm In. mm
200-600 8-5/8 219 2 51 5/16 8 1-5/8 41 2-13/32 61 601-800 8-5/8 219 2-1/2 63 3/8 9 2 51 2-13/32 61
801-1200 10-3/4 273 2-1/2 63 3/8 9 2 51 3-15/32 88 1201-1600 10-3/4 273 3 76 7/16 11 2-3/8 60 3-15/32 88
1601-2000 10-3/4 273 3-1/2 89 1/2 13 2-3/4 70 3-15/32 88
2001-2500 10-3/4 273 4-1/2 114 3/4 19 3-1/2 89 3-15/32 88 2501-3000 10-3/4 273 5 127 3/4 19 4 102 3-15/32 88 3001-4000 10-3/4 273 5-3/4 146 3/4 19 4-3/4 121 3-15/32 88
4001-5000 10-3/4 273 6-1/4 159 1 25 5-1/4 133 3-15/32 88 5001-6000 10-3/4 273 7-1/8 181 1 25 5-3/4 146 3-15/32 88
Safety Note: Class L fuses are dimensioned for one-way interchangeability. A Class L fuse of any lower ampere rating can be substituted for a given Class L fuse.