symphony
®
breastpump kit
juego extractor de leche
materna symphony
®
for use with symphony breastpumps
for double or single pumping
para usarse con extractores de leche symphony
para extracción doble o simple
Not made with natural rubber latex or DEHP.
EN instructions | ES instrucciones
No está hecho con látex de caucho natural ni DEHP.
Questions? Visit www.medela.com or call us at 1-800-435-8316.
3
2
1. Important Safeguards ....................................................................................................4
2. Accessories ....................................................................................................................5
3. Cleaning Overview ..................................................................................................... 6-7
4. Wash – Before fi rst use & after each use................................................................. 8-9
5. Sanitize – Before fi rst use & once per day........................................................... 10-11
6. Tubing Care ............................................................................................................ 12-13
7. Assembly of the Pump Kit ..................................................................................... 14-17
8. Breastshield Sizing ......................................................................................................18
9. Storing, Preparing & Feeding Breastmilk ..................................................................19
9A. Storing Breastmilk ....................................................................................................19
9B. Preparing Breastmilk.................................................................................................19
9C. Feeding Breastmilk ...................................................................................................19
10. Troubleshooting ..................................................................................................... 20-21
11. Supplemental Information...........................................................................................22
PLEASE SAVE THESE INSTRUCTIONS.
Intended Use
The Symphony® Breastpump is a powered breastpump to be used by
lactating women to express and collect milk from their breast.
Product Description
Symphony is a multi-user, hospital grade electric breastpump that
includes 2-Phase Expression® technology and is capable of single and
double pumping.
IMPORTANT
• Plastic bottles and component parts become brittle when frozen and
may break when dropped.
• Bottles and component parts may become damaged if mishandled,
e.g. dropped, over-tightened, or knocked over.
• Take appropriate care in handling bottles and components.
• Do not use the breastmilk if bottles or components become damaged.
T
The warning symbol identifi es all instructions that are important to safety.
Failure to observe these instructions can lead to injury or damage to the
breastpump. When used in conjunction with the following words, the
warning symbols stand for:
WARNING Can lead to serious injury or death.
CAUTION Can lead to minor injury.
NOTE Can lead to material damage.
TIP Useful or important information that is not related to safety.
Table of Contents
Questions? Visit www.medela.com or call us at 1-800-435-8316.
5
4
1. Important Safeguards
When using electrical devices, basic safety precautions should always be followed,
including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT.
WARNING: To avoid health risk and reduce the risk of injury:
• Breastpump kits are a personal care item intended for use by a single user only and
should not be shared between users.
• Inspect the breastpump kit components prior to each use.
o Do not use the components if they are damaged.
o Do not use the components if dirt, mold or other contamination is visible.
• Inspect all appropriate components before each use.
• Clean and sanitize all parts that come in contact with your breast and breastmilk prior
to fi rst use. Sterile kits are ready to use and do not require washing prior to fi rst use.
• Never use while pregnant, as pumping can induce labor.
• Wash all parts that come in contact with your breast and breastmilk after every use.
• Do NOT continue pumping for more than 2 consecutive pumping sessions if no
results are achieved.
• Do not thaw frozen breastmilk in a microwave or in a pan of boiling water.
• If tubing becomes moldy, discontinue use and replace tubing.
• If breastmilk backup occurs, you must clean tubing before your next pumping
session.
• If problems or pain occur, consult your lactation consultant or physician.
CAUTION: Can lead to minor injury:
• Pump only with the breastpump in an upright position.
• Do NOT shorten tubing between breastshield and pump.
• Make sure the voltage of the device is compatible with the power source.
• Plug the power cord into the breastpump fi rst and then into the wall socket.
• Do NOT use abrasive cleaners/detergents when cleaning breastpump or
breastpump parts.
• Never put breastpump motor in water or a sterilizer, as you can cause permanent
damage to the breastpump.
• Do not attempt to remove the breastshield from your breast while pumping. Turn the
breastpump off and break the seal between your breast and breastshield with your
fi nger, then remove breastshield from your breast.
• If pumping is uncomfortable or causing pain, turn the unit off, break the seal
between the breast and the breastshield with your fi nger and remove the
breastshield from your breast.
• Do not store wet or damp parts as mold may develop.
• Do not use the breastpump kit with a non-compatible breastpump.
• Do not use the breastpump kit for any other purpose than expressing breastmilk.
AUTHENTIC
medela spare parts
Quality & performance
you can trust
Authentic Medela Spare Parts are made with the quality materials
and workmanship you expect and trust, only from Medela.
Non-Medela spare parts can vary signicantly in
terms of product design, materials, and
workmanship; all of which may affect
the performance of your
Medela breastpump.
AUTHENTIC
medela spare parts
Quality & performance
you can trust
Authentic Medela Spare Parts are made with the quality materials
and workmanship you expect and trust, only from Medela.
Non-Medela spare parts can vary signicantly in terms of
product design, materials, and workmanship; all of
which may affect the performance of your
Medela breastpump.
Symphony® Membrane Cap 8100769
Symphony Protective Membrane 8200094
PVC Tubing - Symphony, Lactina®, Classic
™
8007213
PersonalFit™ Connectors 87071
PersonalFit 21 mm Breastshield 87072
PersonalFit 24 mm Breastshield 87073
PersonalFit 27 mm Breastshield 87274
PersonalFit 30 mm Breastshield 87075
PersonalFit 36 mm Breastshield 87084
Replacement Membranes 87088
Replacement Valves & Membranes 87089
2. Accessories
Questions? Visit www.medela.com or call us at 1-800-435-8316.
7
6
Parts to clean:
• Breastshields
• Breastmilk bottle/collection containers
• Lids
• Connectors
• Membranes
• Valves
Breastshield assemblies come
assembled. Separate all parts that will
come into contact with the breast and
breastmilk before cleaning.
Kit components may vary from pictures in this instruction manual.
Note
It's important for you to do the following before using Symphony® for the fi rst time:*
1. For models that include a rechargeable battery, fully charge the battery 12 hours
uninterrupted.
2. Separate all parts.
3. Clean - see instructions:
• Wash – section 4, pages 8-9
• Sanitize – section 5, pages 10-11
3. Cleaning Overview
Note
*Sterile kits are ready to use and do not require washing prior to fi rst use.
Breastpump kits are a personal care item intended for use by a single user
only and should not be shared between users.
Warning
Note
*Sterile kits are ready to use and do not require washing prior to fi rst use.
Detailed cleaning instructions on pages 8-13:
• Wash – page 8
• Sanitize – page 10
• Tubing care – pages 12-13
Breastpump kit &
bottles/containers
Tubing
Before 1st use*
✓ wash
✓ sanitize
After each use
✓ wash
Once per day
✓ sanitize
As needed
✓ wash only if milk or
condensation is in tubing
Questions? Visit www.medela.com or call us at 1-800-435-8316.
9
8
4. Wash – Before first use and after each use*
Breastpump kits are a
personal care ite m intended
for use by a single user only
and sho uld not be sha red
between users.
Warning
You may also wash your kit parts
by following the instr uctions on the
Quick Clean™ Breastmilk Removal
Soap bottle. (sold separately)
Supplies needed:
• Mild dish soap
• Clean dish towel or soft
brush
• Clean sink or bowl
• Drinking-quality water
Parts to wash:
• Breastshields
• Breastmilk bottles/
containers
• Lids
• Valves
• Connectors
• Membranes
5
Note
Store the pump kit in a clean bag/container until
next use.
• Place parts on a clean surface
and/or towel.
• Allow all parts to air dry.
• Store dry parts in a clean, cool
place when not in use. Do NOT
store wet or damp parts.
Rinse all separated parts that
came in contact with breast and
breastmilk in cool water in order
to remove breastmilk residue.
• Soak all separated parts in warm
soapy water for 5minutes.
• Wash each part with a clean dishcloth or soft brush.
• Rinse all separated parts with clear
water.
Wash in sink
Separ ate and wash all parts that come in
contact with breastmilk immediately after
use to avoid dry up of breastmilk residue and
prevent growth of bacteria.
Caution
Only use drinking-quality tap or bottled
water for cleaning.
Caution
2 3
Note
If the individual components of the pump
kit are cleaned in a dish washer, parts may
be discolored by food pigments. This will not
impact part function.
Wash in dishwasher
4
• Wash all separated parts on top
rack of dishwasher.
• Allow all breastpump parts to air
dry in a clean area.
• Store dry parts in a clean, cool
place when not in use.
1
• Separate parts for washing.
Note
• Wash breastpump kit parts after each use.
• Take care not to damage parts of the pump
kit during cleaning.
• It is not necessary to wash tubing,
membrane cap or protective membrane
prior to fi rst use.
• Only wash tubing if condensation or
milk is present.
OR
Note
* Sterile kits are ready to use and
do not require washing prior to
fi rst use.
Questions? Visit www.medela.com or call us at 1-800-435-8316.
11
10
5. Sanitize – Before first use and once per day*
Allow water to cool and gently
remove parts from water with
tongs.
You may also sa nitize your
kit parts by following the
instructions on Medela’s Quick
Clean™ Micro-Steam™ bag.
(sold separately)
5
Note
Store the pump kit in a clean
bag/container until next use.
4
Supplies needed:
• Clean pot for boiling water
• Drinking-quality water
• Tongs
Parts to sanitize:
• Breastshields
• Breastmilk bottles/
containers
• Lids
• Connectors
• Membranes
• Valves
• Place parts on a clean surface
and/or towel.
• Allow all parts to air dry.
• Store dry parts in a clean,
cool place when not in use.
Do NOT store wet or damp
parts.
• Fill a pot with enough water to
cover all parts.
• Bring water to a boil.
• Place parts in boiling water for
10 minutes.
Note
Sanitize breastpump kit parts once daily.
2
3
• Wash hands thoroughly.
• Separate all parts that come in
contact with breastmilk.
Note
If you notice a white residue on your
parts after boiling, you may have a
high mineral content in your water.
Remove residue by wiping parts with
a clean washcloth and air dry. We
recommended that you boil par ts with
distil led water to prevent substantial
miner al build-up over time which may
compromise your parts.
Breastpump kits are a personal
care ite m intended for use by a
single user only and should not
be shared between users.
Warning
1
Note
* Sterile kits are ready to use and do
not require washing or sanitizing
prior to fi rst use.
Questions? Visit www.medela.com or call us at 1-800-435-8316.
13
12
Remove tubing from
breastshield.
6. Tubing Care
1
6
2
3
5
Caution
Unplug breastpump from
power source.
Remove tubing, protective
membrane, and membrane cap.
Clean following steps in section 4.
Rinse tubing in cool water to
remove breastmilk.
• Wash tubing in warm soapy water.
• Rinse tubing with clear water.
• Hang to air dry or shake out any
drops of water from the tubing
and let the pump run with tubing
attached for 1-2 minutes until dry.
Turn off breastpump.
Supplies needed:
• Mild dish soap
• Clean dish towel
• Clean sink or bowl
• Drinking quality water
• Damp (not wet cloth)
Parts needed:
• Tubing
• Symphony
®
pump
• Membrane cap
• Protective membrane
Note
Only wash tubing if condensation or
milk is present.
Breastpump kits are a personal
care ite m intended for use by a
single user only and should not
be shared between users.
Refer to breastpump instructions
for use fo r important safeguards
and operating information.
Warning Warning
• Do not store wet or damp parts as mold
may develop.
• If tubing becomes moldy, discontinue
use and replace tubing. Contact Medela
Customer Service at customer.service@
medela.com or call 1-800-435-8316.
• Inspect tubing after each pumping
session.
4
Questions? Visit www.medela.com or call us at 1-800-435-8316.
15
14
7. Assembly of Pump Kit
1
4
2
5
3
6
Note
• Use Auth entic Medela Spare Par ts
only. See page 5 for details.
• Check pump kit components for
wear or damage before use and
replace if necessary.
• All components must be completely
dry before use for proper
performance a nd to prevent
damage to the pump.
Tip
Carry out all the steps with care and
assemble the pump kit correctly for
optimum performance.
T
Push yellow valve onto inner
ring of connector bottom.
Carefully snap membrane onto
yellow valve until membrane
l i e s fl a t .
Push the breastshield onto
the connector.
Screw connector onto the
bottle/container.
Inser t the tubing into
the corresponding opening
in the connector.
Place the protective membrane
onto a fl at surface and carefully
push the membrane cap down
until it engages.
Inser t the tubing adapter into
the opening in the membrane
cap.
7
8
Wash hands thoroughly with soap and
water before touching breastpump, kit
and breasts. Avoid touching the inside
of containers or lids.
Caution
Parts Needed:
• Tubing
• Symphony
®
pump
• Breastshields
• Breastmilk bottles/containers
• Lids
• Connectors
• Valves
• Membranes
• Membrane cap
• Protective membrane
Refer to breastpump instructions
for use fo r important safeguards
and operating information.
Warning