Medela Swing Flex, Swing Maxi Flex Instruction Manual

Swing Flex™ Swing Maxi Flex
EN
Instructions for use
Petunjuk penggunaan
ID
Mode d‘emploi
NL
Gebruiksaanwijzing
Thank you for choosing the Swing Flex / Swing Maxi Flex breast pump. Breast milk is the natural choice for your baby, but there are reasons and situations where breastfeeding is not possible. For over 50 years, it has been Medela’s conviction that these mothers and babies can be supported. In close cooperation with breastfeeding experts, Medela, one of the market leaders, has researched and developed breast pumps that perfectly meet breastfeeding mother’s needs. For mothers who insist on the best for their babies and themselves. Because you care.
Medela vous remercie d‘avoir acheté un tire-lait Swing Flex/Swing Maxi Flex. Le lait maternel est ce qu‘il y a de plus naturel pour votre enfant, mais dans certaines situations, l‘allaitement au sein n‘est pas possible. Depuis plus de 50 ans, Medela se donne pour mission d‘assister ces mamans et ces bébés en difculté. En étroite collaboration avec des experts de l’allaitement, Medela a développé des tire-laits qui répondent de façon optimale aux besoins des mères allaitantes. Ces appareils s‘adressent aux mères qui ne veulent que le meilleur pour leur bébé et pour elles-mêmes. Parce que votre bien-être est important pour nous.
Hartelijk dank dat u voor de Swing Flex/Swing Maxi Flex borstkolf hebt gekozen. Moedermelk is een natuurlijke keuze voor uw baby, maar er zijn redenen en omstandigheden waarin het niet mogelijk is om borstvoeding te geven. Medela is er al meer dan 50 jaar van overtuigd dat deze moeders en baby‘s ondersteund kunnen worden. In nauwe samenwerking met borstvoedingsdeskundigen heeft Medela, een van de marktleiders, borstkolven onderzocht en ontwikkeld die perfect aansluiten bij de behoeften van moeders die borstvoeding geven. Voor moeders die het beste willen voor hun baby en voor zichzelf. Uit liefde.
Terima kasih telah memilih Pompa ASI Swing Flex / Swing Maxi Flex. ASI adalah pilihan alami bagi bayi Anda, tetapi situasi dan kondisi kadang membuat menyusui tidak mungkin. Selama lebih dari 50 tahun, Medela yakin ada yang dapat dilakukan untuk membantu ibu-ibu dan bayi-bayi ini. Medela, salah satu pemimpin pasar, bekerja sama dengan pakar per-ASI-an, berhasil meneliti dan mengembangkan pompa ASI yang benar­benar memenuhi kebutuhan ibu menyusui. Untuk para ibu yang menginginkan yang terbaik bagi bayi mereka juga mereka sendiri. Karena Anda peduli.
EN
4–35
FR
36–67
NL
68–99
ID
100–131
Table of Contents
44
1. Intended use / Population – Contraindication 5
2. Meaning of symbols 6
3. Important safety information 9
4. Product description Swing Flex 10
5. Product description Swing Maxi Flex 11
6. Cleaning 12
6.1 Cleaning overview 12
6.2 Disassemble
6.3 Wash
6.4 Sanitise
6.5 Cleaning tubing
6.6 Cleaning the motor unit
13
14
14
15
15
7. Preparing for pumping 16
7.1 Mains operation 16
7.2 Battery operation
7.3 Assembling the pump set
16
18
8. Expression 20
8.1 Swing Flex – Preparing for single pumping 20
8.2 Swing Maxi Flex – Preparing for single pumping
8.3 Swing Maxi Flex – Preparing for double pumping
8.4 Swing Maxi Flex – Preparing for hands-free expression with the Easy Expression Bustier
8.5 Pumping
26
24
20
22
9. Storing and thawing breast milk 28
9.1 Storage 28
9.2 Freezing
9.3 Thawing
28 28
10. Troubleshooting 29
11. Warranty / Disposal 30
12. Spare parts and Accessories 31
13. EMC / Technical description 33
14. Technical specifications 34
1. Intended use / Population – Contraindication
The intended use and indications of breast pumps
Breast pumps are intended to be used by lactating women in the hospital or home environ­ment for expressing breast milk. Breast pumps are indicated to alleviate the symptoms of engorgement by expressing milk. In case of mastitis breast pumps support the healing process by removing breast milk from the affected breast. Breast pumps are indicated to relieve sore and cracked nipples and to bring out flat or inverted nipples. Also breast pumps enable mothers to provide breast milk for babies who cannot feed directly at the breast for a variety of reasons such as latch-on problems, cleft palate or premature babies.
5
Intended patient population/user
Adolescent paediatric or adult lactating women. Many women find it convenient, or even necessary, to use a breast pump to express and store their breast milk once they have returned to work, are travelling or are otherwise separated from their baby. Women are often delighted to learn that a breast pump can be used as a supplement to breastfeeding and that some pumps are designed to mimic the suckling of a nursing baby.
Contraindications
There are no known contraindications for the Swing Flex / Swing Maxi Flex breast pump.
2. Meaning of symbols
The warning symbol identifies all instructions that are important for safety. Failure to
66
observe these instructions can lead to injury or damage to the breast pump! When used in conjunction with the following words, the warning symbol stands for:
Warning
Can lead to serious injury or death.
Caution
Can lead to minor injury.
Symbols on the packaging
This symbol indicates that the material is part of a recovery/recycling process.
This symbol indicates a carton package.
This symbol indicates to keep the device away from sunlight.
This symbol indicates to handle the fragile device with care.
This symbol indicates the temperature limitation for operation, transport and storage.
This symbol indicates the humidity limitation for operation, transport and storage.
This symbol indicates the atmospheric pressure limitation for operation, transport and storage.
This symbol indicates to keep the device dry.
i
i
Note
Can lead to material damage.
Info
Useful or important information that is not related to safety.
This symbol indicates that the packaging contains products intended to come in contact with food according to regulation 1935/2004.
This symbol indicates unique GSI Global Trade Item Numbers (GTIN).
This symbol indicates do not dispose the device together with unsorted municipal waste (for EU only).
This symbol indicates to follow instructions for use.
Symbols on the device
This symbol indicates to follow instructions for use.
This symbol indicates the compliance with the essential requirements of the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices.
This symbol indicates the manufacturer.
This symbol indicates do not dispose the device together with unsorted municipal waste (for EU only).
This symbol indicates the compliance with additional USA and Canada safety requirements for medical electrical equipment.
This symbol indicates a type BF applied part.
This symbol indicates manufacturer’s serial number of the device.
This symbol indicates the positioning of battery cell.
This symbol indicates the protection against ingress of solid foreign objects and against harmful effects due to the ingress of water.
This symbol indicates the date of manufacture (four digits for the year and two digits for the month).
Symbols on the mains adapter
This symbol indicates that the mains adapter is a class II device.
7
This symbol indicates the compliance with China Compulsory Certification.
This symbol indicates that the mains adapter is for indoor use only.
This symbol indicates the compliance with USA and Canada safety requirements.
This symbol indicates the compliance with Federal Communications Commission require­ments.
This symbol indicates polarity of d.c. power connector.
This CE-mark indicates the compliance with the low voltage and electromagnetic compatibil­ity directive.
This symbol indicates to not dispose the device together with unsorted municipal waste (for EU only). The solid bar symbol indicates that mains adapter is put on the market after 13 August 2005.
88
SGS
This symbol indicates the compliance with energy efficiency requirements.
This symbol indicates alternating current.
This symbol indicates direct current.
This symbol indicates the compliance with energy efficiency requirements.
This symbol indicates that the mains adapter is safety tested.
This symbol indicates a short-circuit proof safety isolating transformer.
170053-12
S
TÜV SÜD PSB
IP20
Singapore Consumer Protection Registration.
This symbol indicates that the electronic device incorporating transformer(s) and electronic circuitry(ies), converts electrical power into single or multiple power outputs.
This symbol indicates the compliance with AUS/NZ requirements (regulatory compliance mark).
This symbol indicates the compliance with PSE requirements (Japan, Product Safety Electrical Appliance and Material Safety Law).
The KC mark indicates that the product meets Korean EMC and electric safety requirements.
This symbol indicates the protection against ingress of solid foreign objects and against harmful effects due to the ingress of water.
3. Important safety information
MAX. 275 h
MAX. 250 h
Failure to follow these instructions/safety information can lead to danger from the device. Subject to technical changes.
Device
Danger of electrocution! Keep the device dry! Never immerse in water or other liquids!
Do not expose the motor unit to direct sunlight.
9
The Swing Flex / Swing Maxi Flex breast pump is not heat-resistant: Keep away from radiators and open flames.
Never use a damaged device. Replace damaged or worn parts.
The operating life of the Swing Flex breast pump is 275 hours. The service life is two years.
The operating life of the Swing Maxi Flex breast pump is 250 hours. The service life is two years.
Electrical use
Separation from the mains is only assured through the disconnection of the mains adapter from the wall socket outlet. Do not reach for any electrical device if it has fallen into water. Unplug immediately.
Use
Use the Swing Flex / Swing Maxi Flex breast pump only for its intended use as described in this manual.
Do not use the Swing Flex /Swing Maxi Flex breast pump while bathing or showering.
Do not use the Swing Flex / Swing Maxi Flex breast pump while sleeping or overly drowsy.
This is a single user product. Use by more than one person may present a health risk.
Never operate an electrical device if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water.
Repairs must be performed only by an authorised service agency. Do not repair yourself! No modifications to the device are permitted.
Keep the mains adapter away from heated surfaces.
The breast pump should never be left unattended when plugged into a power source.
Do not drive whilst hands-free pumping.
Supervision is necessary when the Swing Flex / Swing Maxi Flex breast pump is used in the vicinity of children.
Contact your lactation consultant or breastfeeding specialist if you experience problems or pain.
Portable and mobile radio frequency communications equipment can affect the Swing Flex / Swing Maxi Flex breast pump.
4. Product description Swing Flex
Swing Flex – single electric 2-Phase
1010
breast pump
1x motor unit:
article 600.0975 spare part 099.0015
on/off button
LED
swing
fixing clip
PVC tubing port
reduce vacuum
breast shields:
1 x 21 mm (article 101035239) 1 x 24 mm (article 101035240)
1x mains adapter
article spare part Euro 4.8V 201.1055 099.0016 UK 4.8V 201.1056 099.0017 AUS/NZ 4.8V 201.1057 099.0018 CN 4.8V 201.1058 099.0276 US/JP 4.8V 201.1059 101033542 KR 4.8V 101034044 101038305
1x Swing Flex tubing
ar ticl e 201.1079 spare part 1010340 02
increase vacuum
let-down button
battery compartment
1x connector
article 200.9728
power adapter port
1x multi lid
ar ticle 20 0.2714
1x lid
1x membrane
1x bottle
article 811.0021
1x bottle stand
article 101033405
Spare parts and accessories available for order can be found in chapter 12.
5. Product description Swing Maxi Flex
Swing Maxi Flex – double electric 2-Phase
breast pump
1x motor unit:
article 200.4932 spare part 099.0270
on/off button
reduce vacuum
1x mains adapter
article spare part Euro 12V 201.1146 099.0271 UK 12V 201.1147 099.0272 AUS/NZ 12V 201.1149 099.0273 CN 12V 101032865 099.0274 US/JP 12V 201.1148 101033543 KR 12V 101034045 101038303
LED
swing maxi
increase vacuum
let-down button
fixing clip
PVC tubing port
battery compartment
power adapter port
breast shields:
2 x 21 mm (article 101035239) 2 x 24 mm (article 101035240)
2x connector
article 200.9728
11
2x multi lid
ar ticle 20 0.2714
2x lid
2x membrane
short tubings
tubing holder
long tubing
1x Swing Maxi Flex tubing
ar ticl e 201.1087 spare part 1010340 03
2x bottle
article 811.0021
2x bottle stand
article 101033405
6. Cleaning
6.1 Cleaning overview
1212
Washing and sanitising are two different activities. They must be done separately to protect you, your baby and the performance of your breast pump.
Wash – To clean the surfaces of the parts by physically removing contamination. Sanitise – To kill living organisms, such as bacteria or viruses, that may be present
on the surfaces of the parts.
When to clean
Before 1st use
After each use
Once per day
When to clean
Breast shield(s)
6.2 disassemble 6.3 wash6.4 sanitise
6.3 wash
6.4 sanitise
Tubing
Connector and
membrane
6.2 disassemble 6.3 wash6.4 sanitise
6.2 disassemble 6.3 wash
6.2 disassemble 6.4 sanitise
Bottles & lids
6.2 disassemble 6.3 wash6.4 sanitise
6.2 disassemble 6.3 wash
6.2 disassemble 6.4 sanitise
Motor unit
As needed
see chapter 6.5 see chapter 6.6
6.2 Disassemble
*
Caution
• Do not spray or pour liquid directly onto the pump.
• Only use drinking-quality water for cleaning.
• Take apart and wash all parts that come in contact with the breast and breast milk immediately after use to avoid drying up of milk residues and to prevent growth of bacteria.
• Do not clean the tubing with Quick Clean bags in the microwave.
• Unplug the breast pump before cleaning the motor unit.
i
Note
• The pump set requires no maintenance.
• Take care not to damage parts of the pump set during cleaning.
• Do not use the breast milk if bottles or components become damaged.
13
• Remove and dispose the protective cover* from the breast shield before first use.
• Disassemble the pump set into its individual parts (breast shield, connector, membrane, milk bottle).
• Open back cap of the connector by squeezing both flaps.
• Check all parts for damage.
• Replace damaged or worn parts.
6. Cleaning
1414
6.3 Wash
Before first use and after each use
Sink Stovetop
1. Rinse all parts with cold, clear
drinking-quality water (approx. 20 °C).
2. Clean these parts with plenty of
6.4 Sanitise
Before first use and once per day
Cover all parts, except the tubing, with water and boil at least for 5minutes. Dry after sanitising.
warm, soapy water (approx. 30 °C). Use a commercially available washing-up liquid, preferably without
Microwave
artificial fragrances and colouring (pH neutral).
3. Rinse the parts with cold, clear
drinking-quality water for 10–15seconds (approx. 20 °C). Dry after washing.
OR
OR
Dishwasher
Place all parts, except for the tubing, on the top rack or in the cutlery section. Use a commercially available dish­washing detergent. Dry after washing.
Use Quick Clean* bags in the micro­wave in accordance with the instruc­tions. Dry after sanitising.
* Accessories available for order:
see chapter 12. For more information, visit www.medela.com.
Drying
Dry with a clean cloth or leave to dry on a clean cloth. Put the clean parts in a clean storage bag or a clean environment. Do not store parts in an airtight container/bag if moist. It is important that all residual moisture dries.
6.5 Cleaning tubing
1
No visible residues
No cleaning needed.
With visible residues
1. Rinse tubing in cool water
2. Wash tubing in warm, soapy water
3. Rinse tubing with clear water
4. Shake out water droplets
5. Hang to air dry
Do not sanitise the tubing.
6.6 Cleaning the motor unit
i
Note
• If the individual components of the pump set are cleaned in a dishwasher, parts may be discoloured by food pigments. This has no impact on the function.
• The membrane at the connector prevents the milk from flowing into the tubing, however, inspect the tubing after each pumping session for visible residues. If there are visible residues in the tubing, follow the instructions in chapter 6.5.
15
1
To clean the motor unit, wipe the housing with a clean, damp (not wet) cloth. You may use drinking-quality water and a basic washing-up liquid or a non-abrasive detergent.
2
Additionally you may use an alcohol-based disinfecting agent.
7. Preparing for pumping
1616
Warning
• Mains operation:
Follow the exact order of the steps.
• Only use the mains adapter supplied with the Swing Flex / Swing Maxi Flex.
• Make sure the voltage of the mains adapter is compatible with the power source.
Info
i
• You can operate the SwingFlex / Swing Maxi Flex breast pump via battery or mains.
• Battery operation:
The batteries do not need to be removed when the mains adapter is used for pumping.
• Regularly check the condition of the batteries in the motor unit.
• If Swing Flex / Swing Maxi Flex will remain unused for a longer period of time, remove the batteries from the battery compartment.
• Batteries last for 4 – 6 pumping sessions (approx. 1 ½ hours pumping time).
7.1 Mains operation
1
Plug the mains adapter cord into the motor unit.
7.2 Battery operation
1
Open the battery compartment on the back in the direction of the arrow.
2
Plug the mains adapter into the mains socket. The motor unit is now ready for operation.
17
2
Insert four AA Mignon LR6 batteries for Swing Flex . Insert six AAA Micro 1.5 V batteries for Swing Maxi Flex.
3
Close the battery compartment. The pump is ready for operation via battery.
7. Preparing for pumping
1818
Caution
• Wash hands thoroughly (at least one minute) with soap and water before touching the breast and pump parts. Dry your hands with a fresh towel or a single-use paper towel.
• Also, bottles and component parts may become damaged if mishandled, e.g. dropped, over-tightened, or knocked over.
• Take appropriate care in handling bottles and components.
i
Note
• Use Medela original accessories only.
• Hold the tubing by the connecting piece while attaching and detaching it.
• All components must be completely dry before use.
i
Info
7.3 Assembling the pump set
1
Check pump set components for wear or damage before use and replace if neces­sary. Make sure parts are cleaned according to chapter 6 before assembling the pump set. Carefully place the membrane into the connector with the flap into the opening of the connector. Make sure that the membrane forms a seal around the edge of the connector.
4
• Carry out all the steps with care and assemble the pump set correctly. Other­wise a good vacuum may not be achieved.
Screw bottle into connector.
19
32
Close the lid of the connector until it audibly clicks.
5 6
Insert the tubing into the corresponding opening in the lid of the connector.
Insert the breast shield onto the connector.
Insert the other end of the tubing into the motor unit.
8. Expression
2020
Caution
• Step 2 (chapters 8.1, 8.2, 8.3):
• The product comes with two different breast shield sizes 21 mm and 24 mm.
• Answer the following questions to find out whether the available breast shield sizes fit:
• Does your nipple rub the tunnel sides to the point of causing discomfort?
• Do you see excessive areola being pulled into the tunnel?
• Do you see any redness?
• Is your nipple or areola turning white?
• Do you feel unexpressed milk after breast milk pumping?
If you answered “YES” to any of these questions, consider trying a new size by following the measuring instructions at www.medela.com. If you are still unsure that you selected the right breast shield size, contact your lactation consultant or breastfeeding specialist. See brochure “Choosing your Medela breast shield size”.
8.1 Swing Flex – Preparing for single pumping
1
The oval breast shield can be rotated (360°) and placed in the desired position to have the most comfortable fit for you.
8.2 Swing Maxi Flex – Preparing for single pumping
1
i
Note
• Step 3 (chapters 8.1, 8.2, 8.3):
Do not hold the pump set by the bottle. This can lead to blockage of the milk ducts and engorgement.
Insert the unused short tubing into the tubing holder.
Place the breast shield on your breast so that your nipple is properly centred in the tunnel.
2 3
32
For more information
on pumping, see
Hold the breast shield onto your breast with your thumb and index finger. Support your breast with the palm of your hand.
21
chapter 8.5.
Place the breast shield of one bottle on the first breast so that the nipple is prop erly centred in the tunnel.
For more information
on pumping, see
chapter 8.5.
Hold the breast shield onto your breast with your thumb and index finger. Support your breast with the palm of your hand.
8. Expression
2222
Caution
• Step 2 (chapter 8.3):
• Wash hands thoroughly (at least one minute) with soap and water before touching the breast, the clean pump parts and clean pump set. Dry your hands with a fresh towel or a single-use paper towel.
• Do not hold the pump set by the bottle. This can lead to blockage of the milk ducts and engorgement.
i
Info
• Double pumping saves time and increases the energy content of the milk.
8.3 Swing Maxi Flex – Preparing for double pumping
1
The oval breast shield can be rotated (360°) and placed in the desired position to have the most comfortable fit for you.
4
Switch on the breast pump with
.
23
2
Place the breast shield on your breast so that your nipple is properly centred in the tunnel.
5
3
Hold the breast shield onto your breast with your thumb and index finger. Support your breast with the palm of your hand.
1
For more information
Place the second breast shield on your breast so that your nipple is properly
centred in the tunnel.
on pumping, see
chapter 8.5.
8. Expression
i
2424
Note
Easy Expression Bustier must be pur-
chased seperately. More information on www.medela.com
8.4 Swing Maxi Flex – Preparing for hands-free expression with the Easy Expression Bustier
1
Put on the Easy Expression Bustier and close it using the hook on top.
4
Connect the assembled pump set to the breast shields.
2 3
25
Leave the zip open slightly.
5
Start pumping.
Place the breast shield on your breast under the bustier such that your nipple is
centred in the tunnel of the breast shield.
For more information
on pumping, see
chapter 8.5.
8. Expression
2626
Caution
• Contact your your lactation consultant or breastfeeding specialist if you can express only minimal or no milk, or if expression is painful.
i
Note
• Always disconnect the Swing Flex /Swing Maxi Flex from the power source after expression.
• Only fill the bottle to the 150 ml mark.
i
Info
• Swing Flex / Swing Maxi Flex switches off automatically if it has been running for 30 minutes with no interaction.
• Do not kink the tubing during expression.
The following table shows the different LED status:
8.5 Pumping
1
Switch on the breast pump with . The stimulation phase lasts a maximum
æ
of two minutes. The stimulation phase will then automatically change to the expression phase.
4
Lights up On
Does not light up Off
Even, regular flashing Stimulation phase
Light constantly on Expression phase
Rapid flashing Min./Max. vacuum
Switch off the breast pump with .
2 3
27
If your milk starts to flow earlier, press the
button to change to the expression phase. Make sure that the milk is flowing into
æ
the bottle properly.
5 6
Use the bottle stand to prevent the bottle from tipping over.
The Max. Comfort vacuum can be adjusted in every phase. Max. Comfort vacuum: Use
to increase the vacuum until it is slightly uncomfortable. Press vacuum, until it is comfortable again.
Close the bottle with a lid. Follow the instructions in chapter 9
æ
“Storing and thawing breast milk”.
to reduce the
Clean in accordance
with chapter 6.
9. Storing and thawing breast milk
9.1 Storage
2828
Storage guidelines for freshly expressed breast milk (for healthy term babies)
Room temperature
16 to 25 °C
(60 to 77 °F)
Up to 4 hours is best
*Up to 6 hours for milk
expressed under very clean conditions
Refrigerator 4 °C (39 °F) or colder
Up to 3 days is best
*Up to 5 days for milk
expressed under very clean conditions
Freezer
–18 °C (0 °F )
or colder
Up to 6 months is best
*Up to 9 months for milk
expressed under very clean conditions
*Guidelines for expressing milk under very clean conditions: Before expressing breast milk, mothers should wash their hands with soap and water or an
alcohol-based hand sanitiser. The pump parts, bottles and pumping area must be clean. Breasts and nipples do not need to be washed before pumping.
• These guidelines for storage and thawing of breast milk are a recommendation. Contact your lactation consultant or breastfeeding specialist for further information.
• Store breast milk in the coldest spot of the refrigerator (at the back of the glass shelf above the vegetable compartment).
Breast milk thawed in the refrigerator
At room temperature: Up to 2hours
Refrigerator: Up to 24 hours
Do not refreeze!
9.2 Freezing
• Freeze expressed breast milk in plastic bottles or milk storage bags. Do not fill the bottles or bags more than 3/4 full to allow space for possible expansion.
• Label the bottles or bags with the date and volume of expression.
• Plastic bottles and component parts become brittle when frozen and may break when dropped.
• Do not use the breast milk if bottles or components become damaged.
9.3 Thawing
Caution
Do not thaw or warm breast milk in a microwave or a pan of boiling water. This helps preserve important components and prevents burns.
• To preserve breast milk components, thaw the milk overnight in the refrigerator. Alterna­tively, hold the bottle or bag under warm water (max. 37 °C / 98.6 °F).
• Gently swirl the bottle or bag to mix any fat that has separated. Avoid shaking or stirring the milk.
10. Troubleshooting
Problem
Solution
29
If the motor is not running
If there is low or no suction
If condensation appears in the tubing
The pump becomes wet
Check presence of mains current. Check the position of the batteries in the battery compartment.
Verify the membrane is clean and not damaged. Make sure that the membrane forms a seal around the edge of the connector and the lid is firmly connected with the connector. Check all connections. Check if the ends of the tubing fit securely into the back of the connector and into the port on the breast pump. During single pumping, insert the unused tubing into the tubing holder. There should be no water in the tubing. Do not kink the tubing during expression. Ensure the breast shield forms a complete seal around the breast. All components must be completely dry.
Clean the tubing as described in chapter 6.5. Shake out any water drops.
Unplug the mains adapter from the socket. Switch off the pump. Do not place the pump upside down. The control panel must point upwards. Store the pump in a dry, warm place for 24 hours.
Note:
Do not expose the pump to direct sunlight. Do not accelerate the drying process by use of heat.
11. Warranty / disposal
Warranty
3030
The “International Warranty” brochure contains detailed warranty information.
Disposal
This is a single user product. Use by more than one person may present a health risk. The unit is made of metals and plastics and should be disposed of in accordance with the European directives 2011/65/EU and 2012/19/EU. Additional, local guide-lines must also be observed. Please take care that you dispose of the unit and its accessories in accord­ance with your local disposal guidelines.