Medela Sonata Instruction Manual

Sonata
TM
Instructions for use
PLEASE SAVE THESE INSTRUCTIONS
1. Important Safeguards
WARNING: To avoid fire, electrocution, or serious burns:
• This is a single-user product. Use by more than one person may present a health risk and voids the warranty.
• Always unplug electrical product immediately after use except for when charging.
• Do not place or store product where it can fall or be pulled into a tub or sink.
• The breast pump and accessories are not heat-resistant: keep away from heated surfaces or open flames.
• Do not use near flammable materials.
• The breast pump should never be left unattended when plugged into a power source.
• Never operate an electrical device if it has a damaged cord or plug, is not working properly, or if it has been dropped or damaged. If damage is found, immediately discontinue use and call Medela Customer Service at 1-800-435-8316.
• Do not use an electrical outlet device that has been exposed to water or other liquids including:
- Do not use while bathing or showering.
- Never place or drop into water or other liquids.
- Do not run water over breast pump.
- If a device has been exposed to water or other liquids, do not touch, unplug the device from electrical outlet, turn off and contact manufacturer.
T
The defined signal words identify all instructions that are important to safety. Failure to observe these instructions can lead to injury or damage to the breast pump or yourself. When used in conjunction with the following words, the defined signal words stand for:
WARNING Can lead to serious injury or death.
CAUTION Can lead to minor injury.
NOTE Can lead to material damage.
TIP Useful or important information that is not related to safety.
When using electrical products, especially when children are present, basic safety precautions should always be followed.
READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT.
Questions? Visit www.medela.com or call us at 1-800-435-8316.
WARNING: To avoid health risk and reduce the risk of injury:
• This device cannot be serviced or repaired. Do not repair yourself. Do not modify the device.
• Never use a damaged device. Replace damaged or worn parts.
• Use only the power adaptor that comes with the breast pump.
• Use the breast pump only for its intended use as described in this manual.
• Do not use the breast pump while sleeping or overly drowsy.
• Do not use Sonata breast pump while operating a moving vehicle.
• Inspect all appropriate pump components before each use.
• If tubing becomes moldy, discontinue use and replace tubing.
• Pumping can induce labor. Do not pump until after giving birth. If you become pregnant while breastfeeding or breast pumping, consult with a licensed healthcare professional before continuing.
• If infected with Hepatitis B, Hepatitis C, or Human Immunodeficiency Virus (HIV), pumping breast milk will not reduce or remove the risk of transmitting the virus to your baby through your breast milk.
• Do not microwave or boil breast milk. Microwaving can cause severe burns to baby’s mouth from hot spots that develop in the milk during microwaving. (Microwaving can also change the composition of breast milk.)
• Clean and sanitize all parts that come into contact with your breast and breast milk prior to first use.
• Wash all parts that come into contact with your breast and breast milk after every use.
• Only use Medela recommended parts with your SonataTM Breast Pump.
• Close supervision is necessary when the breast pump or accessories are used in the vicinity of children.
CAUTION: Can lead to minor injury:
• Portable and mobile radio frequency communications equipment can affect the breast pump.
• Make sure the voltage of the power adaptor is compatible with the power source. See Section 23 for technical specifications.
• Wash hands thoroughly with soap and water before touching breast pump, kit and breasts, and avoid touching the inside of bottles or lids.
• Separate and wash all parts that are exposed to breast milk immediately after use. This will help remove breast milk residue and prevent growth of bacteria.
• Always inspect breast shields, connectors, valves, membranes, bottles, lids, and tubing prior to use for cleanliness. Contact Medela Customer Service if cleaning does not resolve the issue.
• Only use drinking-quality tap or bottled water for cleaning your breast pump and parts.
• Do not store wet or damp parts as mold may develop.
• Do not run pump with wet tubing. Doing so may damage the breast pump.
• If you are experiencing discomfort at the base of the nipple due to rubbing of your breast tissue against the breast shield tunnel, use of a lubricant such as Tender CareTM Lanolin may be beneficial. For assistance with correct breast shield sizing and comfort please visit www.MedelaBreastshields.com or see a lactation consultant/breastfeeding specialist.
• If pumping is uncomfortable or causing pain, turn the unit off, break the seal between the breast and the breast shield with your finger and remove the breast shield from your breast.
• Contact your health care professional or breastfeeding specialist if you can express only minimal or no milk or if expression is painful. See Section 7 & 8 for more information.
• While some discomfort may be felt when first using a breast pump, using a breast pump should not cause pain. For assistance with correct breast shield sizing and comfort please visit www.MedelaBreastshields.com or see a lactation consultant / breastfeeding specialist.
• Do not try to express with vacuum that is too high and uncomfortable (painful). The pain, along with potential breast and nipple trauma, may decrease milk output.
• Make sure tubing is not kinked or pinched while pumping.
• Do not hold the pump kit by the bottle. This can lead to blockage of the milk ducts and engorgement. See Section 11 for more information.
• The breast pump uses Bluetooth® technology. Please follow your air carrier rules for the use of Portable Electronic Devices when flying with your breast pump.
• Using a breast pump on an aircraft is not recommended. The cabin pressure may affect the breast pumps performance.
Note
• Plastic bottles and parts become brittle when frozen and may break when dropped.
• Bottles and parts may become damaged if mishandled (e.g., dropped, over-tightened, or knocked over).
• Take appropriate care in handling bottles and components.
• Do not use the breast milk if bottles or components become damaged.
1. Important Safeguards (cont.)
Questions? Visit www.medela.com or call us at 1-800-435-8316.
PLEASE SAVE THESE INSTRUCTIONS.
THIS IS A SINGLE-USER PRODUCT.
Indications for use
The SonataTM breast pump is a powered breast pump to be used by lactating women to express and collect milk from their breast. The Sonata Breast Pump is a single user device.
Tip
It is best to wait until your breast milk routine is established (approximately 4 weeks) before expressing breast milk, unless otherwise advised by your healthcare professional.
If you have medical reasons or other needs for exclusively pumping, it is recommended that you use a hospital-grade (multi-user) breast pump such as the Medela Symphony® Breast Pump. To learn more, visit www.medelabreastfeedingus.com.
Contraindications for use
Product Description
This breast pump is a personal-use electric breast pump that includes 2-Phase Expression® technology and is capable of single and double pumping.
The operating life of this breast pump is defined to be approximately three 15-minute sessions per day, for one year. The operating life for the breast pump kit is 6 months.
There are no known contraindications for use with this product.
T
Questions? Visit www.medela.com or call us at 1-800-435-8316.
1. Important Safeguards ................................................................................................2-5
2. Product Description ...................................................................................................8-9
3. Getting Started ............................................................................................................. 10
4. Cleaning Overview ....................................................................................................... 11
5. Cleaning Instructions .............................................................................................12-13
6. Breast Pump & Tubing Care................................................................................... 14-15
6A Cleaning the breast pump ......................................................................................... 14
6B Tubing care ............................................................................................................... 15
7. Breastfeeding Information .......................................................................................... 16
8. Breast Shield Sizing ..................................................................................................... 17
9. Assembling Your Breast Pump .............................................................................. 18-19
10. Powering Your Breast Pump..................................................................................20-22
10A Charging your breast pump ..................................................................................... 20
10B Battery care & status codes ...............................................................................20-21
10C Power adaptor care................................................................................................. 22
10D Traveling outside the U.S. ........................................................................................ 22
11. Operating Your Breast Pump ................................................................................. 23-26
11A Glossary, controls & icons........................................................................................ 23
11B Single pumping ....................................................................................................... 24
11C Double pumping...................................................................................................... 24
11D Pumping steps ................................................................................................... 25-26
12. Finding Your Maximum Comfort VacuumTM ............................................................... 27
13. Features ................................................................................................................... 28-33
Breast Pump Connectivity ..........................................................................................28-29
Selecting a rhythm .......................................................................................................... 30
Setting the timer ............................................................................................................. 31
Pausing your breast pump .............................................................................................. 32
Silencing your breast pump chimes ................................................................................ 33
14. Storing Breast Milk ...................................................................................................... 34
15. Preparing & Feeding Breast Milk ............................................................................... 35
16. Troubleshooting ...................................................................................................... 36-41
Air leak alert .................................................................................................................... 36
Battery drained ............................................................................................................... 37
Battery broken ................................................................................................................ 38
Bluetooth broken ............................................................................................................ 39
General alert ................................................................................................................... 40
Additional troubleshooting............................................................................................... 41
17. Long-term Storage ...................................................................................................... 42
18. Disposal ........................................................................................................................ 43
19. Supplemental Information .......................................................................................... 44
20. Warranty ....................................................................................................................... 45
21. Meaning of Symbols .................................................................................................... 46
22. EMC/Technical Description ...................................................................................47-53
23. Technical Specifications ............................................................................................. 54
Table of Contents
AUTHENTIC
medela spare parts
Quality & performance
you can trust
2x PersonalFit™ Breast Shields (24 mm) Applied Part
2x PersonalFit™ Breast Shields (27 mm) Applied Part
For other breast shield sizes, see Section 8
Replacement 87073 (24 mm) Replacement 87274 (27 mm)
4x Bottles
Item 6007135
4x Lids
Item 8107183
2x Bottle stands
Item 8107322
2x Membranes
Item 8207086 Replacement 68055
2x Connector caps
Item 8007282
2x Valves
Item 6 007151
2x Connector bodies
Item 101033253
2. Product Description
2x Breast shield assemblies
Replacement 68054
Your breast pump system includes
Medela reserves the right to substitute any component or accessory with a replacement of equivalent performance.
(1x) Power adaptor
Item 9007068 Replacement 68050
1x Ice pack
It em 8117010 Replacement 87092
1x Cooler bag
Item 3007304 Replacement 67068 (replacement includes ice pack & 4 bottles with lids)
1x Bag
Item 3007396 Replacement 68052
Questions? Visit www.medela.com or call us at 1-800-435-8316.
Rhythm
1x Tubing
Item 8007278 Replacement 68053
Speed/Vacuum level
Rhythm selection
Decrease vacuum
Programmable timer
Start/Stop
Stimulation phase
Expression phase
One-touch letdown
Increase vacuum
Silence control
Status icon light
sonata
Display Icons
Controls
Air leak alert
Battery status
External power connected
Chimes “off”
Timer “on”
Bluetooth® connectivity
sonata
Tubing port
Power adaptor port
Power button
Handle
1x Breast pump
Short Tubing
(connects to breast shield assemblies)
Tubing Holder
Long Tubing
(connects to breast pump)
10
3. Getting Started
Note
It is important for you to do the following before using your breast pump for the first time:
1. Plug the Sonata into an external power source. Charge the battery for 12 hours. (See Section 10, Powering Your Pump).
2. Separate all parts that are exposed to the breast or breast milk prior to cleaning.
3. Clean - see Section 5.
Use your thumb to separate the connector cap and body.
Pull down on valve to remove from connector body. Do not rotate.
Parts to clean
Separate all parts that are exposed to
the breast and breast milk prior to cleaning.
Questions? Visit www.medela.com or call us at 1-800-435-8316.
11
When to Wash
Breast Shields
Breast Pump Kit
Bottles & Lids
Before 1st use
3 wash
3 sanitize
3 wash
3 sanitize
3 wash
3 sanitize
After each use
3 wash 3 wash 3 wash
Once per day
3 sanitize 3 sanitize 3 sanitize
4. Cleaning Overview
sonata
Washing and sanitizing are two different activities. They must be done separately to protect you, your baby and the performance of your breast pump.
Wash – To clean the surfaces of the parts by physically removing contamination.
Sanitize – To kill living organisms, such as bacteria or viruses, that may be present on the
surfaces of the parts.
Detailed cleaning instructions on pages 12-15:
• Wash – Section 5
• Sanitize – Section 5
• Breast Pump and Tubing Care – Section 6
When to Wash Tubing
Breast Pump
Carry Bag
As needed
3 See tubing care -
Section 6
3 wipe with clean,
damp cloth
3 wipe with clean,
damp cloth
12
Supplies needed:
Mild dish soap or Medela Quick Clean™ Breastmilk Removal Soap
• Clean dish towel or soft brush
• Clean sink or bowl
• Drinking-quality water
• Tongs
• Clean pot for boiling water
Parts to wash or sanitize:
Breast shields
Breast milk bottles
Lids
Connector bodies
Valves
Membranes
Connector caps
5. Cleaning Instructions
1. Disassemble
Separate parts for washing.
• If using the dishwasher, parts may become discolored. This will not impact part function.
• Tubing should only be washed if dirty or milk is present. See Section 6 for more details.
Tip
T
Note
• Take care not to damage parts of the breast pump kit during cleaning.
• Store the dry breast pump kit in a clean bag/container until next use.
• Wash hands thoroughly.
• If you notice a white residue on your breast pump parts after boiling, your water may have a high mineral content. Remove residue by wiping parts with a clean cloth and allow to air dry.
• Distilled water is recommended when boiling parts to prevent substantial mineral build-up over time, which may compromise your parts.
• Separate and wash all parts that are exposed to breast milk immediately after use. This will help to remove breast milk residue and prevent growth of bacteria.
• Only use drinking-quality tap or bottled water for cleaning.
• When cleaning the valves do not use small objects such as brushes. Be careful not to puncture.
Caution
Questions? Visit www.medela.com or call us at 1-800-435-8316.
13
2. Wash
Before first use and after each use
OR
quick clean
micro-steam bag
STEAM CLEAN YOUR
ACCESSORIES AFTER EVERY USE
steam vent / pour spout
thoroughly disinfects most breastpump accessories, bottles, nipples, paciers, and cups
steam cleaning kills 99.9% of most harmful bacteria and germs
works in approximately 3 minutes
20 uses per bag
This bag will hold:
-2 breastshields and valve membranes or
-2 5oz (150ml) breastmilk bottles and caps, or
-2 - 8oz (250ml) breastmilk bottles and caps
quick clean
micro-steam bag
quick clean
micro-steam bag
3. Sanitize
Before first use and once per day
OR
Step 1 – Fill pot with water to cover all
parts. Bring to a boil. Step 2 – Place parts in boiling water for
10 minutes. Step 3 – Allow parts to air dry. Store
dry parts in a cool place when not in use. Do not store wet or damp parts.
Step 1 – Use Medela's Quick Clean Micro-Steam™ bags. Sold separately (Follow instructions as provided on bag)
Step 2 – Place parts on a clean surface and/or towel. Allow parts to air dry. Store dry parts in a cool place when not in use. Do not store wet or damp parts.
Microwave
StovetopSink
Dishwasher
Step 1 – Rinse all separated parts that
touch the breast and breast milk in cool water to remove breast milk residue.
Step 2 – Soak in warm soapy water for 5 minutes, then wash and rinse.
Step 3 – Allow parts to air dry. Store dry parts in a cool place when not in use. Do not store wet or damp parts.
Step 1 – Wash all separated parts by using the top rack of your dishwasher.
Step 2 – Place parts on a clean surface and/or towel. Allow parts to air dry. Store dry parts in a cool place when not in use. Do not store wet or damp parts.
10
minutes
5
minutes
14
sonata
1
6. Breast Pump & Tubing Care
Warning
Do not immerse the
breast pump in water; do not run water over the breast pump.
• When cleaning the breast pump display, only use a damp, soft cloth with mild dish soap. Other cleaners or abrasive cloths may degrade the display performance.
Wipe pump unit with a clean, damp cloth.
6A. Cleaning the breast pump
Supplies needed:
Mild dish soap
• Clean dish towel
• Clean sink or bowl
• Drinking-quality water
Parts needed:
Tubing
• Breast pump
sonata
Tip
T
• Tubing should only be washed if dirty or milk is present. Follow instructions in Section 6B.
• There is no need to clean tubing if condensation inside the tube is from previous washings or atmospheric conditions. Follow drying instructions in Section 6B.
Questions? Visit www.medela.com or call us at 1-800-435-8316.
15
sonata
2
4 3
Caution
• Do not store wet or damp parts as mold may develop.
• If tubing becomes moldy, discontinue use and replace tubing. To find replacement parts visit www.ShopMedela.com.
• Do not use breast pump with wet tubing;
doing so will cause damage to your breast pump.
6B. Tubing care
To properly clean your tubing
Washing tubing
• Rinse tubing in cool water.
• Wash tubing in warm, soapy water.
• Rinse tubing with clear water.
• Shake out water droplets.
• Hang to air dry.
• Tubing does not need to be washed before first use.
• Inspect tubing after each pumping session.
Turn off breast pump and unplug from power source.
To remove tubing from the breast pump, grab the tube adaptor and pull directly from the tubing port. Do not wiggle or pull tubing at an angle.
Remove tubing from breast shield.
1
16
Common pumping questions & answers
How often should you breast pump?
A breast pump is a replacement for when you are separated from your baby. It is important to pump when the baby would normally be breastfeeding. For example, a working mother may pump 2-3 times during an 8-hour work day.
How long should your pumping session last?
Pumping times can vary from mother to mother. Pumping sessions usually last from 15 to 30 minutes.
How should your breasts feel before and after pumping?
Before pumping, your breasts will have a firm, heavy feeling. After pumping, your breasts should feel soft with no firm areas. Firm areas could indicate that the breast is not completely drained.
7. Breastfeeding Information
Questions? Visit www.medela.com or call us at 1-800-435-8316.
17
8. Breast Shield Sizing
Caution
• While some discomfort may be felt when first using a breast pump, using a breast pump should not cause pain. If you are unsure about breast shield sizing, please contact a health care professional or breastfeeding specialist who can help you get a proper fit.
If you are experiencing discomfort at the base of the nipple due to rubbing of your breast
tissue against the breast shield tunnel, use of a lubricant such as Tender CareTM Lanolin may be beneficial.
1. Medela’s PersonalFit™ sizing
Pumping should not hurt. For maximum comfort and pumping efficiency, Medela offers five breast shield sizes.
Visit MedelaBreastshields.com to view the full guide to help you determine your optimal size based on your nipple diameter.
2. Test your breast shield size
1. Start with the 24 mm that came with your pump, or the size determined by measuring.
2. Center nipple and gently hold breast shield against your breast.
3. Adjust for Maximum Comfort Vacuum™, to achieve optimum suction level.
4. Refer to images while pumping in expression.
3. Should you try a new size?
• Does your nipple rub sides of tunnel, to the point of causing discomfort?
• Do you see excessive areola being pulled into tunnel?
• Do you see any redness?
• Is your nipple or areola turning white?
• Do you feel unexpressed milk after pumping?
If you answered “YES” to any of these questions, consider trying a new size by following the measuring instructions above.
If you are still unsure if you selected the correct size, see a lactation consultant, breastfeeding specialist, or visit MedelaBreastshields.com for assistance in choosing the right size breast shield.
36
mm
27
mm
30
mm
24
mm
21
mm
Too Small
Nipple
Areola
Correct Fit
Nipple
Areola
Nipple
Areola
Too Large
Nipple
Areola
Nipple
Areola
Nipple
Areola
• Nipple rubs along side of tunnel
• Try a larger size
• Nipple is centered and moves freely
• Nipple and excessive areola are pulled into the tunnel
• Try a smaller size