Mean Well HLG-40H-24, HLG-240H-24, NPF-90-24, NPF-60-24, HLG-185H-24 User Manual [EN]

...
Page 1
Installation Manual
North America
European Harmonized
Live and ACL
Black
Brown
Neutral and ACN
white
Blue
PE and FG (Class I only)
Green
Green/yellow
Type:LED Power Supply
Families:AP, CEN, CLG, ELG, ELN, GSC, HBG, HLG, HLN, HLP, HSG, HVG, LCM, LP, LPF, PLC, NPF, OWA, PCD,
PLC, PLD, PLM, PLN, PLP, PWM, ULP
Introduction
The LED power supply is a dedicated LED driving device that delivers a constant current/voltage or generates an adjustable current controlled by an external dimmer to LEDs. Depending on its types or design concept, some of them not only have PFC capability but also can be located in a harsh environment such as dusty, humid places. Mean Well’s LED power supplies include metal case, plastic case, and PCB types.
Installation
1Before commencing any installation or maintenance work, please disconnect the power supply from the utility.
Ensure that it cannot be re-connected inadvertently!
2Keep proper ventilation around the unit and do not stack any object on it. Also a 10-15 cm clearance must be
kept when the adjacent device is a heat source.
3Mounting orientations other than standard orientation or operate under high ambient temperature may
increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheet to receive the optimum mounting position and information about the de-rating curve.
4Current rating of an approved primary /secondary cable should be greater than or equal to that of the unit.
Please refer to its specification.
5For LED power supplies with waterproof connectors, verify that the linkage between the unit and the lighting
fixture is tight so that water cannot intrude into the system.
6For dimmable LED power supplies, make sure that your dimming controller is capable of driving
these units. For ELN series, either “D” or “P” type, require 40mA each unit; for those with “3 in 1” dimming function, e.g. HLG and LPF series, require 0.15mA each unit.
7Wiring: The wire color will vary by country, please refer to the table below.
aConnect the FG wire (green or green/yellow) of the LED power supply to PE (green or green/yellow), this
step can be skipped when the unit is marked class II, ungrounded.
bConnect the ACL wire (black or brown) of the LED power supply to Live (black or brown). cConnect the ACN wire (white or blue) of the LED power supply to Neutral (white or blue).
Page 2
Installation Manual
Model
B10
B16
C10
C16
D10
D16
APC-8
11
17
18
29
37
59
APC-12
11
17
18
29
37
59
APC-16
8
13
14
23
28
46
APC-25
5 9 9
15
18
30
APC-35
3 5 6 9 12
19
APC-8E
11
17
18
29
37
59
APC-12E
11
17
18
29
37
59
APC-16E
8
13
14
23
26
42
APV-8
11
17
18
29
37
59
APV-12
11
17
18
29
37
59
APV-16
8
13
14
22
28
44
APV-25
5 9 9
15
18
30
APV-35
4 6 6
10
13
21
APV-8E
11
17
18
29
37
59
APV-12E
11
17
18
29
37
59
APV-16E
8
13
14
22
28
44
CEN-60
20
32
20
32
20
32
CEN-75
16
25
16
25
16
25
CEN-100
11
19
11
19
11
19
CLG-60
20
32
20
32
20
32
CLG-100
1 3 3 5 6
10
CLG-150
1 3 3 5 6
10
ELG-75
4 7 7
11
14
23
ELG-100
2 3 4 6 8
12
ELG-150
2 3 3 5 6
11
ELG-75-C
4 7 7
11
14
23
ELG-100-C
2 3 4 6 8
12
ELG-150-C
2 3 4 6 8
13
ELN-30
3 4 5 8 10
16
ELN-60
2 3 3 5 7
11
GSC18
26
42
26
42
26
42
GSC25
26
42
26
42
26
42
GSC40
22
36
22
36
22
36
HBG-100
3 4 5 8 10
16
HBG-160
2 4 4 7 8
12
HBG-240
1 2 2 3 4
7
HBG-60
18
28
20
32
20
32
8The maximum number of the LED PSUs that can be connected to a circuit breaker at 230V is shown as below.
Page 3
Installation Manual
Model
B10
B16
C10
C16
D10
D16
HLG-40H
7
12
13
20
26
41
HLG-60H
6 9 10
16
20
32
HLG-80H
2 3 3 6 7
12
HLG-100H
3 4 5 8 10
16
HLG-120H
3 5 5 9 10
17
HLG-150H
2 4 4 7 8
13
HLG-185H
2 4 4 7 6
11
HLG-240H
1 2 3 4 5
8
HLG-320H
1 1 1 2 3
5
HLG-600H
1 1 1 2 2
3
HLG-60H-C
5 8 8
13
16
26
HLG-80H-C
3 4 5 8 10
16
HLG-120H-C
2 4 4 6 8
13
HLG-185H-C
1 2 2 3 4
7
HLG-240H-C
1 2 2 3 4
7
HLG-320H-C
0 1 1 2 3
5
HLN-40H
7
12
13
20
26
41
HLN-60H
6 9 10
16
20
32
HLN-80H
2 3 3 6 7
12
HLP-40H
7
12
13
20
26
41
HLP-60H
6 9 10
16
20
32
HLP-80H
2 3 3 5 6
10
HSG-70
4 6 7
11
14
22
HVG-65 (480V)
7
12
12
20
25
40
HVG-100 (480V)
3 5 5 8 10
17
HVG-150 (480V)
2 4 4 6 8
13
HVG-240 (480V)
2 4 4 7 9
15
HVG-320 (480V)
1 2 2 4 5
8
HVGC-65 (480V)
7
12
12
20
25
40
HVGC-100 (480V)
3 5 5 8 10
17
HVGC-150 (480V)
2 4 4 6 8
13
HVGC-240 (480V)
2 4 4 7 9
15
HVGC-320 (480V)
1 2 2 4 5
8
LCM-25
16
26
27
44
50
80
LCM-40
16
26
27
44
29
47
LCM-60
15
25
20
32
20
32
LCM-25DA
16
26
27
44
50
80
LCM-40DA
16
26
27
44
29
47
LCM-60DA
15
25
20
32
20
32
LPC-20
5 8 9
14
18
29
LPC-35
2 4 4 7 9
15
Page 4
Installation Manual
Model
B10
B16
C10
C16
D10
D16
LPC-60
2 3 3 6 7
12
LPC-100
1 1 1 2 3
5
LPC-150
2 3 4 6 5
8
LPF-16
9
14
15
24
30
48
LPF-25
8
12
13
21
27
43
LPF-40
7
12
13
20
26
41
LPF-60 5 8 9 14
18
29
LPF-90 2 4 4 6 8 13
LPF-16D
9
14
15
24
30
48
LPF-25D
8
12
13
21
27
43
LPF-40D
7
12
13
20
26
41
LPF-60D
5 8 9
14
18
29
LPF-90D
2 4 4 6 8
13
LPH-18
10
17
18
28
36
57
LPHC-18
8
13
14
22
28
44
LPL-18 (115V)
10
16
16
27
20
32
LPLC-18 (115V)
7
12
12
20
20
32
LPV-20
5 8 9
14
18
29
LPV-35
2 4 4 7 9
14
LPV-60
2 3 4 6 8
12
LPV-100
1 2 2 3 4
7
LPV-150
1 2 2 3 4
7
LPVL-150 (115V)
1 1 1 2 2
4
NPF-40
6 9 10
16
20
32
NPF-60
6 9 10
16
20
32
NPF-90
2 3 3 6 7
12
NPF-120
2 4 4 6 8
13
NPF-40D
6 9 10
16
20
32
NPF-60D
6 9 10
16
20
32
NPF-90D
2 3 3 6 7
12
NPF-120D
2 4 4 6 8
13
OWA-60E
1 2 2 4 5
8
OWA-90E
2 3 3 6 7
12
OWA-120E
2 4 4 6 8
13
OWA-60U
1 2 2 4 5
8
OWA-90U
2 3 3 6 7
12
OWA-120U
2 4 4 6 8
13
PCD-16A (115V)
36
58
36
58
36
58
PCD-16B
80
128
80
128
80
128
PCD-25A (115V)
23
37
23
37
23
37
PCD-25B
50
80
50
80
50
80
Page 5
Installation Manual
Model
B10
B16
C10
C16
D10
D16
PCD-40B
29
47
29
47
29
47
PCD-60B
20
32
20
32
20
32
PLC-30
40
64
40
64
40
64
PLC-45
26
42
26
42
26
42
PLC-60
20
32
20
32
20
32
PLC-100
1 3 3 5 6
10
PLD-16A (115V)
36
58
36
58
36
58
PLD-16B
80
128
80
128
80
128
PLD-25
45
72
50
80
50
80
PLD-40B
29
47
29
47
29
47
PLD-60B
20
32
20
32
20
32
PLM-12
100
160
100
160
100
160
PLM-25
50
80
50
80
50
80
PLM-40
29
47
29
47
29
47
PLN-20
61
98
61
98
61
98
PLN-30
40
64
40
64
40
64
PLN-45
26
42
26
42
26
42
PLN-60
20
32
20
32
20
32
PLN-100
1 3 3 5 6
10
PLP-20
57
92
61
98
61
98
PLP-30
40
64
40
64
40
64
PLP-45
26
42
26
42
26
42
PLP-60
20
32
20
32
20
32
PWM-40
6 9 10
16
20
32
PWM-60
6 9 10
16
20
32
PWM-90
2 3 3 6 7
12
PWM-120
2 4 4 6 8
13
ULP-150
2 4 4 6 8
13
Note: These calculated values are based on MCB S200 series manufactured by ABB except for
9For other information about the products, please refer to www.meanwell.com for details.
Warning / Caution !!
1Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
2Risk of irreparable damage. LED power supplies with IP64 to IP66 rating must be located indoors or in a
location where these units can be sheltered from the rain if outdoors.
3Please do not install LED power supplies in places with high ambient temperature or close to fire source.
Please refer to the specifications about the maximum ambient temperature limitations.
HVG/HVGC series, which are calculated by using MCB S260 series of the same manufacturer.
Page 6
Installation Manual
China
MEAN WELL (GUANGZHOU) ENTERPRISES Co., LTD. 2F, A Building, Yuean lndustry Park, Huangcun,Dongpu Yown, Tianhe District, Gungzhou, China Post Code:510660 Tel: +86-20-2887-1200 Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC. 44030 Fremont Blvd., Fremont, CA 94538, U.S.A. Tel: +1-510-683-8886 Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V. Langs de Werf 8, 1185XT Amstelveen, The Netherlands Tel: +31-20-758-6000 Web: www.meanwell.eu
4Output current and output wattage must not exceed the rated values on the specifications. 5The FG ( ) must be well connected to PE(protective earth) if the unit equips with it. 6All MW’s PSUs are designed in accordance with EMC regulations and the related test reports are available by
request. Since they are belong to component power supplies and will be installed inside system enclosure, when they are integrated into a system, the EMC characteristics of the end system must be re-verified again.
Manufacturer MEAN WELL ENTERPRISES Co., LTD. No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 24891, Taiwan Tel: +886-2-2299-6100 Web: www.meanwell.com
Branch Office
Page 7
Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly Use Period of Electronic Information Products Appendix B, adopting table look-up to verify the Environment Friendly Use Period
Part Name
Hazardous Substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr6+)
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
PCB and its components
X O X O O
O
Metal structure parts
X O O O O
O
Plastic structure parts
O O O O O
O
Accessories
O O O O O
O
Cables X O O O O O
O: The concentration of the hazardous substances within the homogeneous material of that product is less than
the concentration limits set by GB/T 26572-2011.
X: The concentration of the hazardous substances within the homogeneous material of that product is over the
concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.
Declaration of China RoHS Conformity
In order to reduce the impacts on the environment and take the more responsibility for protecting the earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products.
Environment Friendly Use Period Label
Names and Contents of Hazardous Substances Lists
Loading...