Mean Well GS36E05, GS36E09, GS36E12, GS36E24, GS36E48 Service Manual

Page 1
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTA GE
RATED CURRENT
CURRENT RANGE
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note. 7)
OTHERS
CONNECTOR
NOTE
RATED POWER (max.)
VOLTAGE TOLERANCE
LINE REGULATION Note.5
LOAD REGULATION Note.6
SETUP, RISE, HOLD UP TIME VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
OVER VOLTAGE
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF DIMENSION
PACKING PLUG
CABLE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
36WAC-DC Industrial Adaptor
GS36E05-P1J GS36E09-P1J GS36E12-P1J GS36E24-P1J GS36E48-P1J
GS36E05
Note.2
5V
4.5A 3.5A
0 ~ 4.5A 0 ~ 3.5A
22.5W 31.5W
Note.3
90mVp-p 90mVp-p 100mVp-p 180mVp-p 240mVp-p
Note.4
±5.0% ±5.0% ±3.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±5.0% ±5.0% ±3.0% ±2.0% ±2.0%
1000ms, 20ms, 15ms/230VAC 1000ms, 20ms, 15ms/115VAC at full load 90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
76.5% 81.5% 84.5% 85.5% 87.5%
0.7A / 100VAC
60A / 230VAC
0.25mA / 240VAC
110 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage Protection type : Clamp by zener diode
-20 ~ +50 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
TUV EN60950-1 approved
I/P-O/P:4242VDC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
692.3Khrs min. MIL-HDBK-217F(25 )
79*54*33mm (L*W*H) 226g ; 60pcs / 15.5kg / CARTON See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
GS36E09
9V
GS36E series
Features :
Universal AC input / Full rangeNo load power consumption<0.3WEnergy efficiency Level Comply with EU ErP2 pole EURO plugClass power (without earth pin)Protections: Short circuit / Overload / Over voltagePass LPSFully enclosed plastic case2 years warranty
GS36E12
12V
3A
0 ~ 3A
36W
GS36E24
24V
1.5A 0.75A
0 ~ 1.5A
36W 36W
GS36E48
48V
0 ~ 0.75A
File Name:GS36E-SPEC 2015-05-20
Page 2
36WAC-DC Industrial Adaptor
GS36E series
Mechanical Specification
38
NAME PLATE
79
60 10mm±
UL1185 16AWG 1000 50mm±
33
70 10mm±
Plug Assignment
Unit:mm
C"+"
11 0.5mm±
ID 2. 1 x OD 5.5
54
Derating Curve
100
70
LOAD (%)
-20 10 20 30 40
for 5~9V
for 12~48V
50
Standard plug: P1J
P1J
P/N
OUTPUT
CENTER
+
Static Characteristics
100
90
80
70
60
LOAD (%)
50
40
90 10095 120110 160140 200180 240220 264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:GS36E-SPEC 2015-05-20
Loading...