(Fa m i lies : C S P, E N P, G 3 , G 5 , H E P, H S P, L RS, MSP, NE , N E S , P F C , P S P, PS PA , RS, RS P,
RST, SE, SPV, UHP, USP)
Introduction
Enclosed type switching power supplies possess a metal or plastic case for covering their internal PCB and will be
installed inside the case of the end system. Mean Well’s enclosed type power supplies include 2 different groups of
power supplies, with built-in fan and without built-in fan, depending on their rated power or design concept.
Installation
(1)Before any installation or maintenance work, please disconnect your system from the utility.
Ensure that it can’t be re-connected inadvertently!
(2)Keep enough insulation distance between mounting screws and internal components of power supplies. Please
refer to case drawing on specifications to receive the maximum length of mounting screw.
(3)Mounting orientations other than standard orientation or operate under high ambient temperature may
increase the internal component temperature and will require a de-rating in output current. Please refer to
the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(4)Fans and ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept
(6)Torque can be various due to different material, please refer to the following chart.
A Recommend torque for aluminum:
Size of screw (Imperial units) Recommend torque (kgf-cm)
3-56
4-40
4-48
5-40
5-44
6-32
6-40
8-32
8-36
2.3±20%
3.0±20%
3.3±20%
4.5±20%
4.7±20%
5.6±20%
6.3±20%
10.4±20%
10.8±20%
Size of screw (Metric Units) Recommend torque (kgf-cm)
M2.5
M3
M3.5
M4
M5
M6
M7
M8
2.2±20%
4.1±20%
6.5±20%
9.7±20%
19.5±10%
33.1±10%
55.3±10%
80.6±10%
Page 3
Installation Manual
B Recommend torque for iron:
Size of screw (Imperial units) Recommend torque (kgf-cm)
3-56
4-40
4-48
5-40
5-44
6-32
6-40
8-32
8-36
5.0±20%
6.9±20%
7.0±20%
9.4±20%
9.9±20%
12.0±20%
13.4±20%
21.8±20%
23.0±20%
Size of screw (Metric Units) Recommend torque (kgf-cm)
M2.5
M3
M3.5
M4
M5
M6
M7
M8
4.6±20%
8.8±20%
13.7±20%
20.4±20%
41.1±10%
69.1±10%
117.5±10%
169.4±10%
If above mentioned is not enough due to special application,Nylok Blue Patch screw is recommend, and extra
torque can be added if needed.
(7)Recommended wires are shown as below.
AWG 18 16 14 12 10 8
Rated Current of
Equipment (Amp)
Cross-section of
2
Lead(mm
)
6A 6-10A 10-16A 16-25A 25-32A 32-40A
0.75 1.00 1.5 2.5 4 6
Note: Current each wire carries should be de-rated to 80% of the current
suggested above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact.
(8)Wiring: The wire color will vary by country, please refer to the table below.
North America European Harmonized
Live and ACL Black Brown
Neutral and ACN white Blue
PE and FG (Class I only) Green Green/yellow
(a)Connect the FG wire (green or green/yellow) of the power supply to PE (green or green/yellow), this step
can be skipped when the unit is marked class II, ungrounded.
(b)Connect the ACL wire (black or brown) of the power supply to Live (black or brown).
(c)Connect the ACN wire (white or blue) of the power supply to Neutral (white or blue).
(d)Make sure all wires are secured to prevent poor contact.
Page 4
Installation Manual
PSU
PSU
(9)For other information about the products, please refer to www.meanwell.com for details.
Warning / Caution !!
(1)Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
(2)Please do not install power supplies in places with high moisture or near the water.
(3)Please do not install power supplies in places with high ambient temperature or near fire source. The
maximum ambient temperature please refer to their specifications.
(4)Output current and output wattage must not exceed the rated values on specifications.
(5)The ground(FG) must be connected to earth ground.
(6)All MW’s PSUs are designed in accordance with EMC regulations and the related test reports are available by
request. Since they are belong to component power supplies and will be installed inside system enclosure,
when they are integrated into a system, the EMC characteristics of the end system must be re-verified again.
(7)This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(a) This device may not cause harmful interference, and
(b) this device must accept any interference received, including interference that may cause undesired
operation.operation.
(8)For series of LRS, NES, PSP, PSPA, RD, RSP, RS, SE that certified with BSMI approvals, flammability of V1 or
above is required for surrounding equipment and operation of this equipment in a residential environment
could cause radio interference.
Page 5
Installation Manual
Manufacturer:
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office:
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
No.11, Jingu South Road, Huadong
Town, Huadu Distric, Guangzhou,
Gungzhou, China
Tel: +86-20-3773-7100
Web: www.meanwell.com.cn
China
SUZHOU MEAN WELL
TECHNOLOGY Co., LTD.
No.77, Jian-Ming Rd. Dong-Qiao,
Pan-Yang lnd. Park, Huang-Dai
Town, Xiang-Cheng District,
Suzhou, Jiang-Su, China
Post Code:215152
Tel: +86-512-6508-8600
Web: www.meanwell.cc
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT Amstelveen, The
Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu
Page 6
Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous
Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly
Use Period of Electronic Information Products Appendix B, adopting
table look-up to verify the Environment Friendly Use Period
Part Name
Hazardous Substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr6+)
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
PCB and its
components
X O X O O
O
Metal structure
parts
X O O O O
O
Plastic structure
parts
O O O O O
O
Accessories
O O O O O
O
Cables X O O O O O
O: The concentration of the hazardous substances within the homogeneous material of that product is less than
the concentration limits set by GB/T 26572-2011.
X: The concentration of the hazardous substances within the homogeneous material of that product is over the
concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.
Declaration of China RoHS Conformity
In order to reduce the impacts on the environment and take the more responsibility for protecting the
earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an
Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and
Electronic Products.
Environment Friendly Use Period Label
Names and Contents of Hazardous Substances Lists
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.