Pure Sine Wave Power Inverter
600W I 1
OOOW
I 1500W
Technical data Rectifying faults
A
If
you have detailed questions on the specifications
of
the
V inverter please contact
us.
Item
number
Rated input voltage
Constant output power
Peak output power
(a
max. of 15 min .)
Maximum input current
Output voltage 115VAC
230VAC
Output frequency
Idle current 115VAC
Consumption
230VAC
Input voltage range
Low voltage alarm
Low voltage shutdown
Efficiency
up
to
Dimensions (mm)
Weight
A301~OOW
A301-1000W
12 V
DC
24 V DC
12 V
DC
I
24 V
DC
600W
1000 W
1000 W
2000W
(650 W)
(1200W)
70 A 40 A
100 A 50 A
115VAC
+/- 3%
230VAC
+/- 3%
50 Hz or 60Hz
to
be
specified
O.
85A O. 45A
1.8
A 1.8A
1.4A
1A
1A
1A
10.
7V-15V
21.4V-30V
10
.7
V-15V
21.4
V-3~
V
< 10.7 V < 21.4 V < 10.7 V < 21.4V
<
10
V < 20 V <
10
V < 20 V
85 %
335 x 236 x
83
395 x 236 x
83
3kg
4
kg
Item
number
A301-1500W
I
Rated input voltage
12 V DC
24 V DC
Constant output power
1500W
I
Peak output power
3000W
a
mal<'.
of
10
min.l (1800
W)
Maximum input current
200 A 100 A
Output voltage 115VAC
115VAC
+/-
3%
I
230VAC
230VAC
+/-
3%
I
Output frequency
50
Hz
or
60Hz to
be
specified
Idle current 115VAC
1A 0.8A
Consumption
230VAC
2A 1.5A
Input voltage range 10.
7V-15V
21.4V-30V
Low voltage alarm < 10.7 V
< 21.4 V
Low voltage shutdown
<
10
V
< 20 V
Efficiency
up
to
85
%
Dimensions (mm 415 x 283 x
100
Weight 5.
75
kg
Fault Cause
Remedy
No
output voltege, LED not
Illuminated
Bad connection between battery and inverter.
Internal fuses defect.
Check the cables and contact
In this case send the unit
back
to
supplier.
No output voltageOVER -
The
inverter has been over- Switch off the inverter and the
TEMP LED illuminates heated.
.
power consuming units.
Wait for approx. 5
-10
min-
Utes and switch
on
the
inverter only.
Reduce the loading and
ensure a better ventilation for the
inverter.
Then switch back
on
the
consuming unit.
Overload LED illuminates Current consumption of the
consuming unit
is
too high.
Possibly, there
is
a short cir-
cuit
in
the consuming unit.
Switch off the inverter and
disconnect the consuming
units.
switch back
on
the inverter
only.
Ifthe
OVERLOAD LED
is
off, there
is
a short circuit at
the consuming unit or the
total load was higher than the
performance specified within
the technical data table.
Check the connecting cable
of the consuming unit for
mechanical damages.
Acoustic signal
in
case of
loading
-
Battery voltage too low. In
case of loading battery voltage
falls below 10.7 V resp.
21.4
V.
The battery must be recharged.