3.4. PHASE 3 – PREPARATION OF COUNTER-WALL..................................................................................9
3.5. PHASE 4 - ASSEMBLY OF FIRE BED (element 2)..............................................................................10
3.6. PHASE 5 - ASSEMBLY OF SIDES (element 3)...................................................................................12
3.7. PHASE 6 - ASSEMBLY OF HOOD SUPPORT (element 4)....................................................................13
3.8. PHASE 7 – WORK TO BE DONE DURING INSTALLATION: HOOD AND PLINTH...................................14
3.9. TECHNICAL TERMS GLOSSARY OF THE PICTURES ..........................................................................15
Index Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL
GUTTUSO
INTRODUCTION
Dear Customer,
thank you for choosing a MCZ product and in particular the Guttuso
cladding Forma Puro 95.
We are sure that, by using it, you will appreciate the quality of an
accurately designed and tested product. Our goal is to combine
technology with easy of use and, above all, safety.
For optimal functioning of the Guttuso cladding and to fully
enjoy the heat and sense of well being that will spread
throughout your home, we suggest that you carefully read this
use and maintenance manual before using the product for the
first time; please contact your dealer should you require
assistance in resolving any doubts or problems.
Congratulations on your choice and remember, the fireplace stove
MUST NEVER be used by children who should always be kept at a
safe distance!
Introduction
page
2
Revisions to the publication
In order to improve the product, the Manufacturer reserves the right to
modify and update this publication without prior notice.
Reproduction, even partial, of this manual without the Manufacturer's
authorisation is prohibited.
Manual preservation.
•Please take care of this manual and keep it in a place that can be
quickly and easily reached.
•If this manual should be lost or destroyed, or if it is in poor
condition, request a copy from your dealer or directly from the
manufacturer, providing product identification data.
Introduction Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 1
GUTTUSO
1. WARNINGS AND WARRANTY CONDITIONS
1.1. SAFETY WARNINGS
•Check the conditions of the surface that will support the
weight of the stove. If it is made of flammable material
(such as wood, carpet, or plastic) provide suitable
insulation.
•The user is fully liable for improper product use,
releasing MCZ from any civil or penal liabilities.
•Any tampering with the fireplace stove, or use of nonoriginal spare parts, may be hazardous to the user and
releases MCZ from any civil or penal liability.
•Incorrect installation or poor maintenance (not
compliant with the provisions of this manual) may cause
damages to persons, animals or property. MCZ is not
civilly or criminally liable in these cases.
page
3
1.2. GUARANTEE CONDITIONS
MCZ guarantees the product, with the exception for the elements
subject to normal wear listed below, for two years from the date of
purchase that is proven by a document that indicates the dealer's name
and date of sale, if the completed warranty certificate was returned
within 8 days and if the product was installed and inspected by a
specialised installation technician and according to the detailed
instructions indicated in the instruction manual supplied with the
product.
The warranty includes the free replacement or repair of parts
recognised as factory defective.
1.2.1. Exclusions
The guarantee does not cover any part that may be defective
due to negligence or careless use, incorrect maintenance,
installation non compliant with that specified by MCZ.
MCZ refuses to accept any responsibility for any damage which may be
caused, directly or indirectly, by persons, animals or things as a result
of the failure to observe all the provisions set forth in the instruction
booklet, especially those concerning warnings on the subject of
installation, use and maintenance of the appliance.
In the event of product inefficiency, please contact your dealer and/or
area importer.
Damages caused by transport and handling are not covered by the
guarantee.
Exclusively refer to the supplied manual for product installation and
use.
The guarantee will be invalidated in the event of damage caused by
tampering with the appliance, atmospheric agents, natural disasters,
Chapter 1 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 1
GUTTUSO
electrical discharges, fire and lack of, or incorrect, maintenance in
terms of the manufacturer's instructions.
REQUEST FOR SERVICE
Requests for service must be addressed to the dealer
who shall forward the request to the MCZ technical
assistance service.
MCZ is not liable in the event the product and any
other accessory is improperly used or modified
without authorisation.
Only original MCZ spare parts must be used for all
replacements.
page
4
Chapter 1 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 2
page
GUTTUSO
5
2. GUTTUSO CLADDING WITH FIREPLACE STOVE FORMA PURO95
The Forma Guttuso model is a recessed cladding, i.e. the fireplace stove is recessed into the wall. Therefore it is
necessary to build a counter-wall that protrudes from the perimeter wall. The depth of the wall to be constructed
is at your discretion provided you comply with all safety distances for the fireplace stove. For this purpose please
refer to the
Manual for Installation and Use
N.B. THE WALL CONSTRUCTED DURING WORK WHERE THE FIRE BED AND HOOD SUPPORT ARE
FASTENED MUST BE LOAD-BEARING, AND EQUIPPED WITH STEEL UPRIGHTS, IF POSSIBLE
DOUBLE. THE METHOD OF CONSTRUCTING THE COUNTER-WALL IS COMPLETELY AT YOUR
DISCRETION. KEEP IN MIND, HOWEVER, THAT A FRONT FACADE IS REQUIRED (WHICH ALSO
INTEGRATES THE HOOD) AND TWO SIDES (WHERE THE UPRIGHTS ARE TO BE FASTENED.
of Forma Puro95.
MURO PERIMETRALEMURO PERIMETRALE
PAVIMENTO
MURO PERIMETRALE
CAPPA
CONTROPARETE (CON CAPPA)
DA REALIZZARE IN OPERA
17
333486
SPAZIO UTILE PER ISOLANTE
1698
104
CONTROPARETE
DA REALIZZARE
IN OPERA
Chapter 2 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 3
GUTTUSO
3. ASSEMBLY OF GUTTUSO CLADDING
3.1. GUTTUSO CLADDING COMPONENTS
page
6
PROFILO COPRIBORDO
PIANO FUOCO
SPALLA
N.COMPONENTE
1
1
2
1SUPPORTO CAPPA
VITE PER CARTONG. 3.9X35
DADO M6 INOX
N.VITERIA IN DOTAZIONE
4
4
Chapter 3 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 3
page
GUTTUSO
7
3.2. PHASE 1 - POSITIONING OF FIREPLACE STOVE FORMA PURO95
Place the Forma Puro95 in the desired position and at a safe distance from the rear wall. Raise the
fireplace stove so that the height of the edge-cover profile with respect to the floor is 333 mm (= height of fire
bed of cladding). A second adjustment of the unit, if necessary, is made during assembly of the cladding.
N.B. There are various ways of raising the Forma Puro95, at your discretion. However, any solution
must ensure safety and stability of the unit.
Before proceeding with the connection to the flue pipe and with complete installation of the fireplace stove,
check the correct position of Forma Puro95 with respect to the fire bed(1) of the Guttuso cladding. When the
check is complete, install the unit Forma Puro 95 in accordance with the instructions in the respective
Installation and Use
and run a quick test for proper operation. If the test is successful, you can install the
Guttuso cladding.
PROFILO
COPRIBORDO
Manual for
333
DISTANZA
DI SICUREZZA
PAVIMENTO
BASE APPOGGIO
FORMA PURO
Chapter 3 Technical service – all rights reserved by mcz spa
Replace the edge-cover profile of the fireplace stove Forma Puro 95 with the Guttuso edge-cover profile (element
1).
PROFILO
COPRIBORDO
FORMA PURO 95
PROFILO
COPRIBORDO
GUTTUSO
Chapter 3 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 3
page
GUTTUSO
9
3.4. PHASE 3 – PREPARATION OF COUNTER-WALL
Before proceeding with the assembly of the Guttuso cladding, it is necessary to create two sides of the counterwall, complete with steel uprights that rest on the floor. The uprights must cover a distance of 10 cm with
respect to the front visible wall. This distance allows the hood support to be fastened to the upright).
N.B. Check the dimension of the fire bed before constructing the counter-wall, since the sides of the
counter-wall must perfectly fit the shape of the fire bed. If necessary, adjust the distance between
sides (if ≠ from 1390 mm) adapting the hole to the actual dimensions.
MONTANTE
IN ACCIAIO
333
MURO PERIMETRALE
MURO PERIMETRALE
ALTEZZA
MINIMA DEL
MONTANTE
830
1390
50
108
==VARIABILE
1390
100
MONTANTI
IN ACCIAIO
Chapter 3 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 3
page
GUTTUSO
10
3.5. PHASE 4 - ASSEMBLY OF FIRE BED (element 2)
N.B. USE CARE WHEN HANDLING STAINLESS STEEL PARTS TO PREVENT IRREPARABLE
SCRATCHES.
N.B. THE FIRE BED OF THE GUTTUSO CLADDING (IN BOTH THE STAINLESS STEEL AND PIASENTINA
STONE VERSION) MUST BE SUPPORTED DURING ASSEMBLY, SINCE THE WEIGHT OF THE VISIBLE
PART CAUSES THE PIECE TO OVERTURN. IT IS STRONGLY ADVISABLE TO PLACE THE SUPPORTS
UNDER THE FIRE BED TEMPORARILY UNTIL FASTENING IS COMPLETE.
Move the fire bed (element 2) near the counterpart. Perforate the counterpart at the threaded bars (d. 6mm) in
the back part of the fire bed.
MONTANTI
IN ACCIAIO
MONTANTI
IN ACCIAIO
FORO PER
BARRA
FILETT.
FORO PER
BARRA FILETT.
Move the fire bed to the counter-wall, inserting the threaded bars in the previously created holes. Fasten the fire
bed using the nuts provided (nuts M6 stainless steel). For greater safety, it is advisable to use 2 nuts for each
threaded bar (nut and locking nut).
When assembly is complete, remove the temporary supports.
Chapter 3 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 3
page
GUTTUSO
11
MONTANTI
IN ACCIAIO
MONTANTI
IN ACCIAIO
DADO-CONTRODADO
POSIZIONE CON
SINGOLO MONTANTE
SUPPORTI
TEMPORANEI
VISTA IN SEZIONE
DADO-CONTRODADO
POSIZIONE CON
DOPPI MONTANTI
SUPPORTO
TEMPORANEO
CONTRO PARETE
MONTANTE
Chapter 3 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 3
page
GUTTUSO
12
3.6. PHASE 5 - ASSEMBLY OF SIDES (element 3)
Position the sides as in the drawing and fasten them with marble cement.
N.B. In the Guttuso stainless steel version, the sides have an inner part in marble covered with a
sliding outer part in steel. It is strongly suggested to use care when handling and assembling the
two sides; keep cement residues off the steel part).
FORO DA
REALIZZARE
IN OPERA
MURO PERIMETRALE
MURO PERIMETRALE
98
SUPERFICIE INTERNA
SUPPORTO CAPPA
A FILO CON
CONTROPARETE
Chapter 3 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 3
page
GUTTUSO
13
3.7. PHASE 6 - ASSEMBLY OF HOOD SUPPORT (element 4)
Set the hood support (element 3) on the sides (element 2), ensuring that it is aligned with the cladding. Push
the hood support towards the fireplace stove until the inner surface of the visible bend is flush with the counterwall (see drawing). Fasten the hood support with the 4 screws for plasterboard 3.9x35 provided. The outermost
screw corresponds to the metal profile that protects the corner of the counter-wall. The innermost screw is at the
steel upright. If necessary, you can make a third hole for installation of the hood support (see drawing).
MURO PERIMETRALE
MURO PERIMETRALE
FORO DA
REALIZZARE
IN OPERA
98
SUPERFICIE INTERNA
SUPPORTO CAPPA
A FILO CON
CONTROPARETE
N.B. The hood support is deep enough to house both the hood and the a panel of insulating
material. The total space available is 98 mm.
Chapter 3 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Chapter 3
page
GUTTUSO
14
3.8. PHASE 7 – WORK TO BE DONE DURING INSTALLATION: HOOD AND PLINTH
After fastening the hood support, the hood can be made using fireproof material. It is strongly suggested to
insulate the hood of the Forma Puro95 fireplace stove.
In the Guttuso stainless steel version, it is necessary to cover the plinth of the fire bed, preferably using the
same material as the counter-wall. Upon completion, the cladding must appear with the fire bed hanging and
protruding from the wall.
In the Guttuso Piasentina stone version, the fire bed is already finished so that it may remain visible. However,
also for this model, it is possible to create a plinth during installation (as with the stainless steel version) so that
only the hanging top is visible.
GUTTUSO ACCIAIO INOX
ZOCCOLO
GUTTUSO PIETRA PIASENTINA CON ZOCCOLO A VISTA
Chapter 3 Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Glossary
GUTTUSO
3.9. TECHNICAL TERMS GLOSSARY OF THE PICTURES
PAGE 5 PAGE 5
CONTRO PARETE (CON CAPPA) DA
REALIZZARE IN OPERA
MURO PERIMETRALE PERIMETER WALL
PAVIMENTO FLOOR
CAPPA HOOD
SPAZIO UTILE PER ISOLANTE SPACE AVAILABLE FOR INSULATION
PAGE 6 PAGE 6
COMPONENTE COMPONENT
PROFILO COPRIBORDO EDGE-COVER PROFILE
PIANO FUOCO FIRE BED
SUPPORTO CAPPA HOOD SUPPORT
VITERIA IN DOTAZIONE NUTS AND BOLTS PROVIDED
VITE PER CARTONGESSO SCREW FOR PLASTERBOARD
DADO M6 INOX NUT M6 STAINLESS STEEL
PAGE 7 PAGE 7
PROFILO COPRIBORDO EDGE-COVER PROFILE
PAVIMENTO FLOOR
DISTANZA DI SICUREZZA SAFETY DISTANCE
BASE APPOGGIO FORMA PURO SUPPORT BASE FORMA PURO
PAGE 8 PAGE 8
PROFILO COPRIBORDO FORMA PURO95 EDGE-COVER PROFILE FORMA PURO95
PROFILO COPRIBORDO GUTTUSO EDGE-COVER PROFILE GUTTUSO
PAGE 9 PAGE 9
MONTANTE ACCIAIO STEEL UPRIGHT
ALTEZZA MINIMA DEL MONTANTE MINIMUM HEIGHT OF THE UPRIGHT
MURO PERIMETRALE PERIMETER WALL
VARIABILE VARIABLE
PAGE 10 PAGE 10
MONTANTI IN ACCIAIO STEEL UPRIGHTS
FORO PER BARRA FILETTATA HOLE FOR THREADED BAR
PAGE 11 PAGE 11
COUNTER-WALL (WITH HOOD) TO BE MADE
DURING WORK
page
15
Glossary Technical service – all rights reserved by mcz spa
Reproduction prohibited
INSTALLATION AND USE MANUAL Glossary
GUTTUSO
MONTANTI IN ACCIAIO STEEL UPRIGHTS
SUPPORTI TEMPORANEI TEMPORARY SUPPORTS
VISTA IN SEZIONE SECTION VIEW
DADO-CONTRODADO POSIZIONE CON
DOPPI MONTANTI
DADO-CONTRODADO POSIZIONE CON
SINGOLO MONTANTE
NUT AND LOCKING NUT POSITION WITH
DOUBLE UPRIGHTS
NUT AND LOCKING NUT POSITION WITH
SINGLE UPRIGHT
CONTRO PARETE COUNTER-WALL
MONTANTE UPRIGHT
PAGE 12 PAGE 12
FORO DA REALIZZARE IN OPERA HOLE TO BE MADE DURING INSTALLATION
MURO PERIMETRALE PERIMETER WALL
SUPERFICIE INTERNA SUPPORTO CAPPA A
FILO CON CONTROPARETE
INTERNAL SURFACE OF HOOD SUPPORT
FLUSH WITH COUNTER-WALL
PAGE 13 PAGE 13
SUPERFICIE INTERNA SUPPORTO CAPPA A
FILO CON CONTROPARETE
INTERNAL SURFACE OF HOOD SUPPORT
FLUSH WITH COUNTER-WALL
FORO DA REALIZZARE IN OPERA HOLE TO BE MADE DURING INSTALLATION
PAGE 14 PAGE 14
GUTTUSO ACCIAIO INOX GUTTUSO STAINLESS STEEL
GUTTUSO PIETRA PIASENTINA CON
ZOCCOLO A VISTA
GUTTUSO PIASENTINA STONE WITH
VISIBLE PLINTH
ZOCCOLO PLINTH
page
16
Glossary Technical service – all rights reserved by mcz spa
Reproduction prohibited
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.