McQuay WVHC012 Parts List

Replacement Parts List No. 700014800
Rev. C 9/2012
Vertical Stack
Water Source Heat Pump
WVHC, WVHF, WVHW
Sizes: 009-036
Design 1
R410a
Contents
Parts List Revision History .................................................................................................................. 3
Nomenclature
Serial Number ............................................................................................................................... 4
Model Number ......................................................................................................................... 4 - 5
Electrical Legend ................................................................................................................................ 6
Basic Unit Layout ................................................................................................................................ 7
Blower Fan Assembly ......................................................................................................................... 8
Drain Pan ............................................................................................................................................ 9
Refrigeration Circuit
Diagrams .................................................................................................................................... 10
Components ........................................................................................................................ 11 - 12
Control Box
Diagrams .................................................................................................................................... 13
Components ............................................................................................................................... 14
Field Installed Accessories ........................................................................................................ 15 - 17
Critical Parts List ............................................................................................................... CPL1-CPL2
Vertical Stack WSHP; WVHC, WVHF 009-036 Design 1 Rev. C 9/12 RPL 700014800 / Page 2
Parts List Revision History
Revision Date Description
New 10/09 New A 11/09 Page 10- Remove Primary Drain Pan. B 6/10 Page 7-8 Add Field Installed Accessories doc. from Dan Adams. Page 16- Add control box and stand off descriptions. Add Connectors H1-9. Add sensors p/n 669008901 & 107201601. C 9/12 Title Page- Change title to include WVHW. Change logo to Daikin McQuay. Updated format and change all drawings to CS6. Pages 4-5 Update serial number format. Move nomenclature to pages 4-5. Add Code 02 =VHW Add Code 05 F= MTIII Controller w/BacNET Card- WSHP Systems. Delete Code 10- Digit 3, C= Corrosion Package. Page 6- Move electrical legend to this page from page 4. Page 7 Basic Unit Layout was moved here. Page 8- Add Support Flange p/ns 669348001, 669348002, 669346901 & 669346902. Add Ring Inlet p/n 060629101. Delete ECM Motor for 265/60/1 p/ns 667794804 & 668986402. Change ECM motor p/n 667794803 to 669287405 & ECM motor p/n 668986401 to 669287406. Add X13 motor p/n 669287404 & 669287403. Page 10- Moved refrigeration circuit drawings to here from page 15 & 16. Page 11-12Numerous changes made. Combined pages 14 thru 16. Added sound blankets p/ns 669280501 & 669280601. Page 14 Combined page 17-18. Change control board p/n 668105601 to 910131839. Change I/O expansion board p/n 668105701 to 910131840. Change LonWorks p/n 668105801 to 910131842 & BacNET p/n 668105901 to 910131841. Added Relay p/n 106500101. Change sensor (DAT, LWT) to p/n 669659901 and sensor (RAT) to p/n 669660001. Page 15-17, Field Installed Accessories moved from page 7-8 Multiple changes were made. Add O. A. Extension Kit p/n 910115524 & 910115525. Deleted Relay p/n 106710801. CPL1- CPL2 - Add Critical Parts List.
13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330
Vertical Stack WSHP; WVHC, WVHF 009-036 Design 1 Rev. C 9/12 RPL 700014800 / Page 3
Nomenclature
Serial Number
AUB U 09 05 00148
Plant Identification Abbreviation
AUB = Auburn
U= Unit
Week of Manufacture
Year of Manufacture
09= 2009 10= 2010
etc.
Serial Number (build sequence)
Model Number
W VHC 1 009 B A GL A C AMC C Y BFT F 12 YYY Code: 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
AY S 080 AY F L YYY Y YY YYY Y Y CR 5 Y 1 Code: 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Code 01: Unit Type
W= Water Source Heat Pump
Code 02: Product Identifier
VHC= Vertical Stacked Heat Pump Chassis VHF= Vertical Stacked Heat Pump Cabinet VHW= Vertical Stacked Geothermal Chassis only
Code 03: Design Series
1= Design 1
Code 04: Unit Size (Nominal Cooling)
009= 9000 BtuH 012= 12000 BtuH 015= 15000 BtuH 018= 18000 BtuH 021= 21000 BtuH 024= 24000 BtuH 030= 30000 BtuH 036= 36000 BtuH
Code 05: Controls
B= MicroTech III Controller- Stand Alone C= MicroTech III Controller w/LonCard D= Microtech III Controller w/BacNet Card F= Microtech III Controller w/BacNet Card- WSHP System
Code 06: Voltage
A= 115/60/1 E= 208-230/60/1 J= 265/60/1
Code 07: Secondary Drain Pan
GL= Galvanized SS= Stainless Steel Y= None
Code 08: Refrigerant A= R410a
Code 09: Isolation Valve
C= 2-Way Motorized 1/2” Iso Valve, Gen’l Close-Off Pr, N.C. V= 2-Way Motorized 1/2” Iso Valve, Gen’l Close-Off Pr, N.O. H= 2-Way Motorized 1/2” Iso Valve, High Close-Off Pr, N.C. D= 2-Way Motorized 3/4” Iso Valve, Gen’l Close-Off Pr, N.C. K= 2-Way Motorized 3/4” Iso Valve, Gen’l Close-Off Pr, N.O. J= 2-Way Motorized 3/4” Iso Valve, High Close-Off Pr, N.C. Y= None
Code 10: Chassis Construction Type Digit 1: Insulation
A= Standard Fiberglass Insulation E= IAQ Cellular Foam Insulation Y= None Digit 2: Sound Option M= Mass Plate & Compressor Sound Blanket S= Mass Plate Only Y= None Digit 3: Corrosion Package Y= None
Continued on next page.
Vertical Stack WSHP; WVHC, WVHF 009-036 Design 1 Rev. C 9/12 RPL 700014800 / Page 4
Nomenclature
Code 11: Coaxial Heat Exchanger
C= Copper Inner Tube/ Steel Outer Tube S= Cupro Nickel Inner Tube/ Steel Outer Tube Y= None
Code 12: Load Balancing Pump
Y= None
Code 13: Discharge Air Digit 1: Primary Discharge
B= Primary Supply- Back F= Primary Supply- Front L= Primary Supply- Left R= Primary Supply- Right T= Primary Supply- Top Y= None Digit 2: Secondary Discharge B= Secondary Supply- Back F= Secondary Supply- Front L= Secondary Supply- Left R= Secondary Supply- Right T= Secondary Supply- Top Y= None Digit 3: Tertiary Discharge T= Tertiary Supply- Top Y= None
Code 14: Power Connection
F= Fused Disconnect with Wire Harness N= Non-Fused Disconnect with Wire Harness H= HACR Breaker
Code 15: Blower Motor Digit 1: Motor
1= Standard 3= ECM Motor 4= X13 Motor Digit 2: Motor Speed 2= 2 Speed Fan-T-STAT Controlled 3= 2 Speed Fan- Unit Toggle Switch
Code 19: Cabinet Height (Inches)
080= 80” Cabinet Height 088= 88” Cabinet Height 092= 92” Cabinet Height 096= 96” Cabinet Height YYY= None
Code 20: Cabinet Construction
AY= Standard Fiberglass Insulation EY= Closed Cell Foam insulation (IAQ Option) FY= Foil-Faced Fiberglass Insulation
Code 21: Riser Mounting
F= Factory Mounted Risers J= Factory Supplied Risers for Field Installation Y= None
Code 22: Riser Location
L= Left Cabinet Piping R= Right Cabinet Piping B= Back Cabinet Piping Y= None
Code 23: Heating Options Digit 1: Heater Type
Y= None
Digit 2: Heater Control Option
Y= None
Digit 3: Always Y
Codes 24: Always Y
Codes 25: Always YY
Codes 26: Always YYY
Codes 27: Color
Y= None
Codes 28: Always Y
Codes 16: Always YYY
Code 17: Flow Control Digit 1: Flow Regulator
A= Auto Flow Regulator Y= None Digit 2: Strainer Y= None
Code 18: Filter
S= Standard 1” Fiberglass P= 2” Pleated MERV7 Y= None
Vertical Stack WSHP; WVHC, WVHF 009-036 Design 1 Rev. C 9/12 RPL 700014800 / Page 5
Codes 29: Agency Listing Digit 1:
C= ETL, CETL, ARI Y= None
Digit 2:
R= RoHS Y= None
Code 30: Packaging
Code 31: Warranty
Code 32: Product Style
1= Style 1
Electrical Legend
C1 .................................. Capacitor - Compressor
.................................. Capacitor - Fan
C2
CC ................................. Compressor Contactor
CM ................................. Compressor Motor
COS ............................... Condensate Overflow Sensor
DSC
............................... Disconnect Switch
............................... Fan Motor Connector Plug
FMP
FMR ............................... Fan Motor Connect Receptacle
FCP ............................... Fan Connector Plug
FCR ............................... Fan Connector Receptacle
FPR
............................... Fan Power Relay
............................... Fan Speed Relay
FSR
FSS ................................ Fan Speed Switch
FS1 ................................ Fuse 1
FS2 ................................ Fuse 2
HP .................................. High Pressure Switch
ISO-** ............................ Isolation Valve - Option
LED1
.................................LED Annunciator/Harness
LP ......................................Low Pressure Switch
MIII ....................................Microtech III Main Board
...................................Main Power Connector Plug
MPP
MPR ...................................Main Power Connector Receptacle
OVL....................................Compressor Overload
PDPG
...............................Primary Drain Pan Ground
PCOS ...............................Primary Cond Overflow Sensor
.....................................Reversing Valve Solenoid
RV
SOS ...................................Secondary Overflow Sensor
SLTS
..................................Suction Line Temp Sensor
TB3 ....................................Terminal Block
TS1 ....................................Fan Speed Terminal Strip
....................................Thermostat Terminal Strip
TS2
TSP ....................................Terminal Strip Connector Plug
TSR
...................................Terminal Strip Conn Receptacle
X1 ......................................Transformer
Vertical Stack WSHP; WVHC, WVHF 009-036 Design 1 Rev. C 9/12 RPL 700014800 / Page 6
Loading...
+ 13 hidden pages