To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.DaikinMcQuay.com
Contents
Parts List Revision History ............................................................................................................................. 3
Unit Nomenclature
Model Number Nomenclature ........................................................................................................................ 4
Serial Number Nomenclature ......................................................................................................................... 4
Model Number- Complete ........................................................................................................................ 5- 10
Main Control Box ...................................................................................................................................... 12
Liquid Line ........................................................................................................................................... 40, 41
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 2
Parts List Revision History
Revision Date Description
NEW 10/11 New
A 11/11 Page 10: Removed System Memory Bub #5 p/n: 300047100. Duplicate of CB p/n.
B 12/11 Page 24: Changed Ref #302 Discharge Hsg. p/n from 331553802 to 331553803.
C 01/12 Page 10: Changed Ref #8 300047103 to 333568101; Ref #9 300047104 to 333568201; Ref #11 300047105 to 333568301; Ref #13 300047106 to 333568401.
Page 11: Deleted duplicate Bub #11. Added new Bub #1 for 2nd VFD fan. Change Ref #5, 6 qty. from 1 to 2.
Page 25: Switched Bub #s 204 & 205 to correct locations on upper right dwg.
D 03/12 Cover & Page 3: Updated to Daikin McQuay logo format.
Page 13: Added Harness p/n 331795502 & dwg. Updated TOC.
Page 28: Added Relief Valve dwg. and updated main unit dwg. to current revision.
Page 29: Changed qty. of Ref # 020 from 2pc. to 1pc. Changed Ref 021 S/O valve from 735039977 to
332422302. Added footnote #3.
Page 41,47: Updated Water Box dwg. Removed component Bubs, except for gaskets. Renumbered Bubs.
Page 42- 44, 48, 49: Removed Water Box components except gaskets. Updated Water Box gaskets to
reflect change to 2pc. design Ref #352 & 366. Renumbered bubs to match Water Box dwg. Added
footnotes.
Page 45: Removed Water Box components except gaskets. Updated Water Box gaskets to reflect change
to 2pc. design Ref #352 & 366. Renumbered bubs to match Water Box dwg. Added footnotes. Added
p/ns for Ref #350, 351 to 3 Pass Flanged Standard Head table.
E 03/12 Page 5- 8 : Updated Code Nomenclature to R33369901 Rev 0A.
Page 9, 10 (NEW): Added 2 pages for additional codes. Repaginated form and updated TOC.
Page 46, 50 (OLD), 48, 52 (NEW): Deleted the Tube Count table. Added note to refer to Nomenclature
section. Re-numbered footnotes as needed.
F 05/12 Page 12: Changed BACNet kit from 332356901 to 332356951, Lon Kit from 332356902 to 332356952,
Modbus kit 332356903 to 332356953.
Page 28: Deleted original footnote #1. Renumbered remaining footnote.
Page 29: Deleted page of IGV actuator detail for 331553401. Repaginated form and updated TOC.
G 5/12 Page 31, 32: Deleted Knockdown kit p/n 332356112 and related footnote information.
H 6/12 Various: Changed "McQuay Parts" to "Daikin McQuay Parts"
Page 40: Added Bub #140 for complete Exp. Valve Assy.
Page 41: Added complete assy p/n 333271501 and corrected Ref #140A Body p/n from 333271501 to
3331552502.I 7/12 Page 5- 10: Updated Coding to Rev. B.
Page 15: Added Snubber Capacitor p/n 300048940, qty. of 6.
J 8/12 Page 25: Changed Impeller Seal ref # 502 from 332027501 to 332027502.K 8/12 Page 13: Added KAIC ratings to ref #8, CBKR. Re-arranged order of ref #8 per KAIC rating.
E3012= Evaporator, 30" Diameter/12' Long; E3612= Evaporator, 36" Diameter/12' Long
9. Evaporator Tube Count / Tube Type
First Digit= Tube Count; 3/4" Diameter Tube
30" Diameter: B= 300; C=262; X=Special
36" Diameter: B= 488; C= 414; D= 352; X= Special
First Digit= Tube Count; 1" Diameter Tube
30" Diameter: E= 178; F= 149; X= Special
36" Diameter: E= 271; F= 243; G= 209; X= Special
First Digit= Tube Count; Mixed Diameter Tube
30" Diameter: J= 155; K= 127; X= Special
36" Diameter: J= 244; K= 215; M= 179; X= Special
Second Digit= Tube Type
E= Turbo EHP .025 Wall, 3/4"; F= Turbo EHP .028 Wall, 3/4"; Q= Turbo EHP .035 Wall, 3/4"; T= TC SS 28FPI .028 Wall, 3/4";
Z= TC Titanium 32FPI .028 Wall, 3/4"; G= CU Turbo .025 Wall, 1"; D= CU Turbo .028 Wall, 1"; H= CU Turbo .035 Wall, 1";
X= Special
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 5
Nomenclature
Model Number- Complete, Continued
10. Evaporator Head / Waterbox Description
First Digit= Number of Water Passes
1= 1 Pass; 2= 2 Pass; 3= 3 Pass; X= Special
Second Digit= Inlet Nozzle Location
L= Left; R= Right
Third Digit= Nozzle Configuration
A= Dished Head Victaulic; B= Dished Head Flanged; C= Waterbox Top Victaulic; E= Waterbox Top Flanged;
G= Waterbox Rear Victaulic; H= Waterbox Rear Flanged; X= Special
11. Evaporator Design Pressures
C1= Refrigerant Side Pressure: 200 PSIG; Waterside Pressure: 150 PSIG ASME
C2= Refrigerant Side Pressure: 200 PSIG; Waterside Pressure: 250 PSIG ASME
C3= Refrigerant Side Pressure: 200 PSIG; Waterside Pressure: 350 PSIG ASME
C4= Refrigerant Side Pressure: 200 PSIG; Waterside Pressure: 150 PSIG Non-ASME
C5= Refrigerant Side Pressure: 200 PSIG; Waterside Pressure: 300 PSIG Non-ASME
XX= Special
12. Evaporator Leaving Water Temperature
Code is listed in tenths of °F. (Example: 0440= 44.0 °F)
13. Evaporator Tube Sheet & Head Material
First Digit= Tube Sheet Material
C= Carbon Steel
N= Monel Clad
S= Stainless Steel Clad
T= Titanium Clad Steel
X= Special
Second Digit= Head Material
C= Carbon Steel
E= Epoxy Coated
X= Special
14. Tube Cleaning System
Y= None
15. Evaporator Revision Level
A= Revision A; B= Revision B
16. Condenser Shell Diameter & Length
C2612= Condenser, 26" Diameter/12' Long
C3012= Condenser, 30" Diameter/12' Long
C3612= Condenser, 36" Diameter/12' Long
17. Condenser Tube Type & Count
First Digit= Tube Count; 3/4" Diameter Tube
30" Diameter: B= 300; C=262; X=Special
36" Diameter: B= 488; C= 414; D= 352; X= Special
First Digit= Tube Count; 1" Diameter Tube
26" Diameter: E= 268; F= 232; X= Special
30" Diameter: E= 339; F= 295; G= 265; X= Special
36" Diameter: E= 534; F= 480; G= 417; X= Special
First Digit= Tube Count; Mixed Diameter Tube
26" Diameter: E= 268; F= 232; X= Special
30" Diameter: E= 339; F= 295; G= 265; X= Special
36" Diameter: E= 534; F= 480; G= 417; X= Special
Second Digit= Tube Type
L= Turbo CSL .025 Wall, 3/4"; N= Turbo CSL .028 Wall, 3/4"; P= Turbo CSL .035 Wall, 3/4";
T= TC SS 28FPI .028 Wall, 3/4"; Z= TC Titanium 32FPI .028 Wall, 3/4"; 1= 90-10 CU-NI .028 Wall, 3/4";
4= 90-10 CU-N .035 Wall, 3/4"; A= CU Turbo .025 Wall, 1"; B= CU Turbo .028 Wall, 1"; C= CU Turbo .035 Wall, 1";
X= Special
Digits 3 & 4
YY= None; XX= Special
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 6
Nomenclature
Model Number- Complete, Continued
18. Condenser Head / Waterbox Description
First Digit= Number of Water Passes
1= 1 Pass; 2= 2 Pass; 3= 3 Pass; X= Special
Second Digit= Inlet Nozzle Location
L= Left; R= Right
Third Digit= Nozzle Configuration
A= Dished Head Victaulic; B= Dished Head Flanged; D= Waterbox Top Victaulic; F= Waterbox Top Flanged;
G= Waterbox Front Victaulic; H= Waterbox Front Flanged; X= Special
19. Condenser Design Pressures
C1= Refrigerant Side Pressure: 200 PSIG; Waterside Pressure: 150 PSIG ASME
C2= Refrigerant Side Pressure: 200 PSIG; Waterside Pressure: 250 PSIG ASME
C3= Refrigerant Side Pressure: 200 PSIG; Waterside Pressure: 350 PSIG ASME
C4= Refrigerant Side Pressure: 200 PSIG; Waterside Pressure: 150 PSIG Non-ASME
C5= Refrigerant Side Pressure: 200 PSIG; Waterside Pressure: 300 PSIG Non-ASME
XX= Special
20. Maximum Condenser Leaving Water Temperature
Code is listed in tenths of °F. (Example: 1050= 105.0 °F)
21. Condenser Tube Sheet & Head Material
First Digit= Tube Sheet Material
C= Carbon Steel
N= Monel Clad
S= Stainless Steel Clad
T= Titanium Clad Steel
X= Special
Second Digit= Head Material
C= Carbon Steel
E= Epoxy Coated
X= Special
22. Condenser Tube Cleaning System
Y= None
23. Condenser Model Revision
A= Revision A; B= Revision B
24. Pressure Vessel Code
A= ASME; C= PED; P= Chinese; 1= British Columbia; 2= Alberta; 3= Saskatchewan; 4= Manitoba; 5= Ontario; 6= Quebec;
7= New Brunswick; 8= Nova Scotia; 9= Prince Edward Island; 0= Newfoundland; U= Yukon
25. Refrigerant Type
134= R134A Refrigerant
26. Refrigerant Weight
Total Refrigerant weight (lbs.) divided by 10 rounded to the next whole number. (Example: 815/10= 81.5, Round up to 082)
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 7
Nomenclature
Model Number- Complete, Continued
31. Controls Options
YYYY= None
32. Insulation
First Digit= Condenser & Evaporator Shell Insulation
H= ¾" Closed Cell Foam Insulation
3= 1½" Closed Cell Foam Insulation
Y= None
X= Special
Second Digit= Condenser & Evaporator Head Insulation
1= Return Head(s) Only
2= Return & Connection Heads
Y= None
X= Special
33. Water Flow Indication
B= Evaporator & Condenser Flow Control; X= Special
34. Paint
1= Standard Paint; X= Special
35. Packaging
2= Open Export Crate; 3= Totally Enclosed Export Crate; 4= Shipping Bag with Standard Wood Skid;
6= Shipping Bag with Totally Enclosed Export Crate; 7= Shipping Bag with Open Export Crate; X= Special
36. Refrigerant Tag
A= Full Factory Charge; N= Holding Charge, Nitrogen; X= Special
37. Special Features
M= Stock Modification; Y= None; X= Special
38. Not a WME Code Item
Y= None
39. Knockdown Option
1= Compressor & VFD removed, run tested, Nitrogen holding charge; 2= Full Knockdown option, Nitrogen holding charge;
3= Refrigerant in Compressor, Full Factory charge; Y= None; X= Special
40. Testing
Y= None
1= Run test only
2, 9, A, B, C, D, E, F, G, H, J, Q, S= Various Witness Tests
3, 4, 5, 6, 7, K, L, M, N, P, R, T= Various Certified Performance Tests
8= Non certified Sound Test
X= Special
0000= Data Calculated from Selection Program (Example: 0150= 150 Tons)
44. Startup
U= Domestic Startup; 7= Canadian Startup; Y= Export, No Startup
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 8
Nomenclature
Model Number- Complete, Continued
45. First Year Warranty
Y= Entire Unit Parts + Labor (Standard); C= Entire Unit Parts + Compressor Labor Only; P= Entire Unit Parts Only (Export standard)
46. Extended Warranty
(Codes C thru K apply to Parts and/or Labor for the complete unit.)
C= Extended 1 year parts; D= Extended 1 year parts + Labor; E= Extended 2 year parts; F= Extended 2 year parts + Labor;
G= Extended 3 year parts; H= Extended 3 year parts + Labor; J= Extended 4 year parts; K= Extended 4 year parts + Labor;
(Codes L thru S apply to the Compressor & Drive Train Only.)
L= Extended 1 year parts; M= Extended 1 year parts + Labor; N= Extended 2 year parts; O= Extended 2 year parts + Labor;
P= Extended 3 year parts; Q= Extended 3 year parts + Labor; R= Extended 4 year parts; S= Extended 4 year parts + Labor;
Y= None; X= Special
LL= Short Circuit Current Rating 25KA (use with 575V); ST= Short Circuit Current Rating 35KA;
MH= Short Circuit Current Rating 50KA (use with 575V); HH= Short Circuit Current Rating 65KA
VH= Short Circuit Current Rating 100KA; XX= Special
62. VFD input RLA Compressor 1
0000= Data Calculated from Selection Program
63. VFD input RLA Compressor 2
0000= Data Calculated from Selection Program (always 0000 unless Code 03= D)
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 9
0000= Data Calculated from Selection Program (always 0000 unless Code 03= D)
75. Starter Special
Y= None; X= Special
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 10
Electrical Legend
Sch. Sym. Description Location
BAS Communication Card Main Control Box
CB1 Circuit Breaker- TX2 Primary VFD Power Supply Plate
CB2- 4 Circuit Breaker- Fans VFD Power Supply Plate
CB4 Circuit Breaker- MCB Trip, Power Meter, ELR, Solenoid VFD Power Supply Plate
CFT1- CFT2 Cooling Fan Control VFD Power Supply Plate
CT1- 6 Current Transducers VFD Chassis
CPU Main Control Board Main Control Box
D1 Diode VFD Chassis
ES Switch- Ethernet Main Control Box
ELR Relay- Earth Leakage VFD Power Supply Plate
EMC EMC Filter VFD Enclosure
EXV1 Electronic Expansion Valve #1 Liquid Line
EXV2 Electronic Expansion Valve #2 Liquid Line
F1- F2 Fuse- Controls Transformer, 2A 600VAC VFD Power Supply Plate
F3- F5 Fuse- IPS, 6A 600VAC VFD Power Supply Plate
F6- F7 Fuse- 150VDC to DC Power Supply, 10A 600VAC VFD Power Supply Plate
F8- F10 Fuse- Power Meter, 10A 600VAC VFD Power Supply Plate
INPUT I/O Board Main Control Box
IPS Intermediate Power Supply VFD Enclosure
L1- 3 Chopper Chokes/Inductors VFD Chassis
LCD LCD Touch Screen Monitor (OITS) Evaporator
LR Line Reactor VFD Enclosure
MCB Main Circuit Breaker VFD Enclosure
P1- P14 DC Power Distribution Terminals VFD Power Supply Plate
PM Power and Current Meter VFD Power Supply Plate
PS2- PS4 Power Supply- VFD VFD Power Supply Plate
PS5 Power Supply- Chiller I/O VFD Power Supply Plate
PS6 Power Supply- Compressor I/O VFD Power Supply Plate
PS7- PS8 Power Supply- Magnetic Bearings VFD Power Supply Plate
Q1- 3 Chopper/IGBT Driver VFD Chassis
Q4- 6 Steering Bridge IGBT VFD Chassis
R1- 4 Resistors VFD Chassis
S01 Sensor- Evaporator Entering Water Temperature Evaporator Inlet
S02 Sensor- Evaporator Leaving Water Temperature Evaporator Outlet
S04 Switch- Evaporator Entering Flow Evaporator Inlet
S05 Sensor- Condenser Entering Water Temperature Condenser Inlet
S06 Sensor- Condenser Leaving Water Temperature Condenser Outlet
S07 Sensor- Condenser Refrigerant Pressure Condenser
S08 Switch- Condenser Entering Flow Condenser Inlet
S09 Sensor- Liquid Line Temperature Liquid Line
S10 Sensor- Compressor Suction Temperature Compressor
S11 Sensor- Compressor Suction Pressure Compressor
S12 Sensor- Compressor Discharge Temperature Compressor Discharge Housing
S13 Sensor- Compressor Discharge Pressure Compressor Discharge Housing
S14 Sensor- Motor Gap Temperature Compressor
S15 Switch- High Pressure Discharge Piping
SW1 Switch- Compressor #1 Main Control Box
SW3 Switch- Remote Start/Stop Remote Mounting
SW4 Switch- Mode Remote Mounting
SW5 Switch- Unit Enable Main Control Box
TDM1- 3 Diode/Thyristor Module VFD Chassis
TS1 Thermal Switch VFD Chassis
TH1, 2 Thermistors VFD Chassis
TX2 Transformer- 480/240/120 VAC, 500A VFD Power Supply Plate
VFD1 VFD Chassis Assembly VFD Enclosure
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 11
24
Controls
Main Control Box
Communication Card
Location
4
7
9
8
18
15
Ref. Schem.
No. Sym. Description Part No. Qty.
4 Board- Chiller I/O Backplane 300047099 1
7 CPU Board- Chiller Controller 300047102 1
N/S Connector, Chiller Controller, Beige 300048948 21
N/S Connector, Chiller Controller, Orange 300048949 4
8 Board- Digital I/O 333568101 1
9 Board- Analog Output 333568201 1
11 Board- IGV Stepper Motor 333568301 1
13 Board- Analog Input 333568401 2
15 Cable- Touch Monitor Power 300047108 1
18 SW5 Switch- Unit Enable 300047109 1
24 SW1 Switch- Unit and Compressor #1 300047110 2
N/S BAS BACnet MS/TP/E Installation Kit 1 332356951 1
N/S BAS Lonmark Installation Kit 1 332356952 1
N/S BAS Modbus Installation Kit 1 332356953 1
N/S= Not Shown on Diagram.
1
Includes the Communication Card and Installation Manual.
13
11
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 12
Controls
VFD Enclosure
1
3
1
8
7
3
10
4
11
5
6
Ref. Schem.
No. Sym. Description Part No. Qty.
1 Fan 120 VAC 600 CFM 300047091 2
3 VFD1 VFD Chassis Assembly- Phases 1- 3 1 300047093 1
4 Fuse 20A/1000VAC 300047094 2
5 Coil- Solenoid 120/60, 10 watt 300047095 2
6 LR Line Reactor 3PH 300047096 2
7 IPS Intermediate Power Supply 300047097 1
8 MCB CBKR Molded Case 25KAIC 600V 400A 300048927 1
CBKR Molded Case 25KAIC 600V 600A 300048929 1
CBKR Molded Case 35KAIC 480V 500A 300047098 1
CBKR Molded Case 35KAIC 600V 500A 300047071 1
CBKR Molded Case 35KAIC 600V 600A 300047100 1
CBKR Molded Case 35KAIC 600V 800A 300048924 1
CBKR Molded Case 50KAIC 600V 400A 300048928 1
CBKR Molded Case 50KAIC 600V 600A 300048930 1
CBKR Molded Case 65KAIC 600V 500A 300047088 1
CBKR Molded Case 65KAIC 600V 600A 300047108 1
CBKR Molded Case 65KAIC 600V 800A 300048925 1
CBKR Molded Case 100KAIC 480V 400A 300047069 1
CBKR Molded Case 100KAIC 480V 600A 300048923 1
CBKR Molded Case 100KAIC 480V 800A 300048926 1
10 Surge Suppressor 480V 300047076 1
11 VFD1 VFD Chassis Assembly- Phases 4- 6 1 300048873 1
1
Refer to VFD Chassis Assembly detail on the following pages.
2
This chassis is present ONLY when Code 04= M3.
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 13
Controls
VFD Chassis- Diagrams
1
4
3
2
15
5
12
6
13
14
7
13
8
11
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 14
Quantity PER Chassis Assembly with the exception of chassis 300048873. VFD Chassis Assembly 300048873 has no
Controller (Ref. #2).
1
Compressor Wiring Harness
Compressor Wiring Harness 331795501
(12/11 & Earlier)
2
The Wiring Harnesses are available as complete assemblies only.
2
Compressor Wiring Harness 331795502
(1/12 & Later)
2
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 15
Controls
VFD Power Supply Plate- Diagram
21
20
19
11
22
12
7
4
8
6
9
5
13
13
14
2
3
18
17
15
14
16
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 16
Controls
VFD Power Supply Plate- Components
Ref. Schem.
No. Sym. Description Part No. Qty.
2 Plate- Partition Gray 300047073 17
3 Terminal Block Gray 300047074 36
4 Terminal Block- Ground Green-Yellow 300047075 9
5 Bracket- End, Snap on 300047190 7
6 ELR Relay- Earth Leakage 300047078 1
7 CB1 Circuit Breaker- Primary 8A 300047079 1
8 CB2- 4 Circuit Breaker- 2 Fans & MCB trip 2A 300047080 3
9 Switch- Fan Failure 331578601 2
11 PS2 DC power supply +15 VDC 100 watts 300047081 1
12 PS3 DC power supply 15 VDC 25 watts 300047082 1
13 PS4, 7 DC power supply +24 VDC 77 watts 300047083 2
14 PS5, 6 DC power supply +24 VDC 100 watts 300047084 2
15 PS8 DC power supply +12 VDC 72 watts 300047085 1
16 DC Distribution Board 300047086 1
17 PM Monitor- Voltage, Power and Current 300047087 1
18 TX2 Transformer 480/240/120V 500VA 349939804 1
19 F1-10 Fuse holder 300047088 7
20 F1-2, F8-10 Fuse 300047089 2
21 F3- 5 Fuse 300047090 3
22 F6-7 Fuse 300046902 2
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 17
Controls
OITS- Operator Interface Touch Screen
Swivel Bracket
15
Swivel Pins
1
1
Main Control Box
18
16
Ref.
No. Description Part No. Qty.
15 Monitor- 15" LCD Touchscreen, Black 330276502 1
16 LCD Support Arm Assembly, Black 330815411 1
18 OITS/Unit Control Box Support Block 330406501 2
1
These parts are included with the Mounting Arm Assembly. Note that Support Arm mounting hardware
(Screws, Washers and Nuts) are also included in the Support Arm Assembly and are not available
separately.
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 18
Control Sensors
Sensor Location Diagrams
1
Top View
Rear View
S14
S13
S12
S15
S10
S07
S11
S09
Evaporator
Connection End View
S04
S06
S05
S08
1
Right Hand connection unit shown. Code 10/18= *R*.
Out
In
Condenser
InOut
S02
S01
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 19
Control Sensors
Components
Ref. Description Part Qty.
No. Number
S01 Sensor- Evaporator Entering Water Temperature 073007203 1
S02 Sensor- Evaporator Leaving Water Temperature 073007203 1
S04 Switch- Evaporator Entering Flow 331796201 1
N/S Cable- Evaporator Entering Flow Switch (5 Meter Lg.) 330571402 1
S05 Sensor- Condenser Entering Water Temperature 073007203 1
S06 Sensor- Condenser Leaving Water Temperature 073007203 1
S07 Sensor- Condenser Refrigerant Pressure 071568601 1
S08 Switch- Condenser Entering Flow 331796201 1
N/S Cable- Condenser Entering Flow Switch (5 Meter Lg.) 330571402 1
S09 Sensor- Liquid Line Temperature 073007203 1
S10 Sensor- Compressor Suction Temperature 331582801 1
S11 Sensor- Compressor Suction Pressure 071568501 1
N/S Cable- Compressor Suction Pressure Sensor 331796801 1
S12 Sensor- Compressor Discharge Temperature 331582801 1
S13 Sensor- Compressor Discharge Pressure 071568601 1
S14 Sensor- Motor Gap Temperature 331795205 1
S15 Switch- High Pressure 074796301 1
N/S= Not Shown on Diagram.
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 20
Compressor
Motor/Bearing Assembly
1
Part No. Description Application Voltage
333507101 MBAW6/6 (Code 04= M4) 380 - 575V
1
Compressor Magnetic Bearing, Rotor, and Stator components are NOT field
replaceable. If replacement is required, the entire assembly must be replaced.
For Compressor Motor/Bearing Assembly field serviceable components see
the following page.
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 21
O-Ring(s) are furnished standard with all fittings. Order additional O-Rings if needed.
ORFS Style O-Rings seat on the face end of the fitting. SAE style O-Rings seat at the
base of the fitting.
2
Refer to the Condenser and Evaporator sections for p/ns and quantities.
3
The original valve design used on units built 1/12 & Earlier used a straight valve and a 90
Degree elbow fitting. This valve arrangement was replaced 2/12 & Later with a 90 degree
valve that does not require an elbow fitting. When replacing an original design valve, the
elbow fitting is removed, and then the listed 90 degree valve is a direct replacement.
2
2
2
2
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 30
O-Ring(s) are furnished standard with each valve. Order additional O-Rings if needed.
ORFS Style O-Rings seat on the face end of the fitting. SAE style O-Rings seat at the
base of the fitting.
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 47
Evaporator
36" Evaporator Diagrams
36" Condenser
Rear View
1
350 355
353 354
110A
(Located on the Front Side
of The Evaporator)
Water Box Head Option
352B
353
354
331330
351
352
331330
366B
352A
366A
1
For 30" Evaporator components (Code 08= E3012) contact Daikin McQuay Parts with model and serial number
information so that the correct part(s) can be identified. 2 Pass Evaporator shown above. For 1 & 3 Pass Evaporators
the Connection Head (Ref# 351) and the Return Head (Ref# 350) are the same. Diagram shows LH piping
connections (Code 10= *L*).
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 48
350 Return Head- Victaulic Water Box Return Head- Flanged Water Box
351 Connection Head- Victaulic Water Box Connection Head- Flanged Water Box
352A Gasket- Water Box Head
352B U-Channel Gasket- Water Box Head
2, 4
070304622 2
2, 4
073258601
355 Gasket- Return Head 070304622 2
366A Gasket- Water Box Cover
366B U-Channel Gasket- Water Box Cover
1
Contact Daikin McQuay Parts with model and serial number information so that the correct
part(s) can be identified.
2
This gasket consists of two parts. The U-Channel Gasket is glued to the baffle that separates the
passes. Order adhesives separately as required; (735026371) and (735026386).
3
Order 4.0 feet of U-Channel PER Gasket.
4
Note that this 2pc. design replaces the original 1pc. design.
2, 4
070304622 2
2, 4
070189804
1
1
1
1
1
1
1
1
5
3
3
5
For 36" 3 Pass Evaporators with Water Box Heads contact Daikin McQuay Parts with model and serial number
information so that the correct part(s) can be identified.
WME0700S- Water Cooled Chiller Rev. K 08/12 RPL 700022800 / Page 50
Evaporator
Tubes, Tube Counts, Sight Glass, Charge Valve & Cap
Tube Counts
For Tube counts see the Nomenclature Model Number- Complete section.
Tube Table
Code 09 Wall Type & Part
(2nd digit) Thickness Material Number
E .025 Turbo EHP, Cu 073238590
F .028 Turbo EHP, Cu 330441418
Q .035 Turbo EHP, Cu 330441414