Replacement Parts List No. 700024700 
New 8/2012
SmartSource™ Single Stage 
Water Source Heat Pump 
WGSH, WGSV
Sizes 007, 009, 012
Design 1
To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.DaikinMcQuay.com
 
 
Page 2
Contents
Parts List Revision History ....................................................................................................................................... 3
Nomenclature
   Serial Number ..................................................................................................................................................... 4
   Model Number ................................................................................................................................................. 4-6
Electrical Legend ..................................................................................................................................................... 7 
Typical Refrigeration Cycles ................................................................................................................................... 8
Blower Fan Assembly .............................................................................................................................................. 9
Refrigeration Circuit .......................................................................................................................................... 10-11
Control Box
   Microtech III Controller ...................................................................................................................................... 12
Field Installed Accessories ............................................................................................................................... 13-15
Critical Parts List............................................................................................................................................... CPL1
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 2
 
 
Page 3
Parts List Revision History
 Rev. Date Description  
NEW   8/12   NEW 
13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440  (763) 553-5330
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 3
 
 
Page 4
Nomenclature
Serial Number
AUB  U   12  05    00148
Plant Identification Abbreviation
AUB = Auburn
U= Unit
Week of Manufacture
Year of Manufacture
12= 2012 
13= 2013
etc.
Serial Number 
(build sequence)
Model Number
      W GSH  007  B  1  A  WL  R   T  5  Y  Y  Y   C   S  YYY   B  2  A   Y   Y  Y   Y   Y  B  A   Y  Y   Y  YYY  
 Code  01 02-03  04   05  06  07  08  09  10   11 12  13  14  15  16  17 -18   19  20  21  22  23  24  25  26   27  28  29  30  31  32-34  
      Y   YYY  S  Y  Y  B  A  B  A  Y  A  T   Y  C   Y  YY  Y   Y   2  Y  Y   S  A   L   K   Y   Y   Y   Y   YY         
 Code  35  36-38  39  40  41 42  43  44  45  46  47  48  49   50  51  52   53  54  55  56  57  58  59   60   61  62  63  64  65  66-67    
      Y   Y  A  Y   Y  Y  Y  A  A  Y   C  Y   Y  YY  FF   ST   ST  YY  YYY   Y  C   Y   Y   YY  1    
Code  68  69  70  71  72  73  74  75  76  77   78  79  80   81   82   83    84    85    86    87  88  89  90   91   92  
Code 01= Unit Type 
W= Water Source Heat Pump
Code 02= Model Type 
GS= High Efficiency, Single Stage
Code 03= Configuration 
H= Horizontal 
V= Vertical
Code 04= Unit Size (BtuH Nominal Cooling) 
007= 7000    
009= 9000 
012= 12000 
Code 05= Unit Control 
B= MicroTech III Unit Controller
Code 10= Discharge Air Location 
E= End (Horizontal Unit only) 
T= Top (Vertical Unit only) 
S= Straight (Horizontal Unit only)
Code 11= Fan Motor 
5= ECM Constant Torque
Code 12= Dehumidification Option 
C= Simplified Dehumidification             
   (Lower CFM no HGRH or no Humidistat) 
D= Humidistat Controlled Dehumidification (No HGRH) 
E= Humidistat only 
Y= None
Code 13= Sound Packages 
Y= None
Code 06= Design Series (Vintage) 
1= Design 1
Code 07= Voltage 
A= 115/60/1 
E= 208-230/60/1 
J= 265/60/1 
Code 08= Range for Entering Water/Glycol Temp. 
GW= Ground Water 
WL= Water Loop 
GL= Ground Loop
Code 09= Return Air Location 
L= Left-Hand Return Air & Right-Hand Piping 
R= Right-Hand Return Air & Right-Hand Piping
Code 14= IAQ Packages (Indoor Air Quality) 
Y= None
Code 15= Coaxial Heat Exchanger Construction 
C= Copper Inner Tube- Steel Outer Tube 
S= Cupro-Nickel Inner Tube- Steel Outer Tube
Code 16= Primary Air Coil Options 
S= Standard 
E= E-Coated
Codes 17-18= Always YYY
Continued on next page.
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 4
 
 
Page 5
Nomenclature
Code 19= Communication Module 
B= BACnet 
F= BACnet - WSHP System 
L= LonWorks 
Y= None
Code 20= Filter Rack 
2= 4-Sided, 2" w/Duct Collar & Door 
3= 4-Sided, 2" w/Duct Collar, Door, Hi-Merv Seal 
4= 4-Sided, 4" w/Duct Collar, Door, Hi-Merv Seal 
Y= None
Code 21= Filter Type 
A= 2" Disposable 
E= Merv 8 Factory Installed 
G= Merv 13 (4" thick) Factory Installed 
Y= None
Code 22= Water Coil- Indoor Air 
E= Waterside Economizer 
Y= None
Code 23= Electric Heating- Indoor Air 
Y= None
Code 24= Control Secondary Heat Type 
B= Boilerless Electric Heat 
E= Emergency Heat 
P= Primary Electric Heat (No Heat Pump Heating) 
S= Supplemental Heat 
Y= None
Codes 32- 34= Always YYY
Code 35= Water Coil Piping (HW or Waterside Economizer) 
A= 3-Way, Motorized- 24V Valve Control, NO to Coax 
Y= None
Codes 36-38 = Always YYY
Code 39= Primary Drain Pan Material 
S= Stainless Steel
Code 40= Secondary Drain Pan Material 
Y= None
Code 41= Compressor Insulation 
Y= None
Code 42= Compressor Isolation 
B= Isolated Base
Code 43= Insulation- Compressor Compartment 
A= 1/2" Fiberglass Skin Faced 
B= 1/2" Fiberglass Foil Faced 
C= 3/8" Closed Cell Foam 
P= Premium
Code 44= Insulation- Air Side 
A= 1/2" Fiberglass Skin Faced 
B= 1/2" Fiberglass Foil Faced 
C= 3/8" Closed Cell Foam 
P= Premium
Code 25= Desuperheater (Hot Water Generator) 
D= Desuperheater 
Y= None
Code 26= Loop Pump 
1S= One Low Head 230 Volt Pump, Grundfos UP26-99F 
1L= One High Head 230 Volt Pump, Grundfos UP26-116F 
2S= Two Low Head 230 Volt Pump, Grundfos UP26-99F 
2L= Two High Head 230 Volt Pump, Grundfos UP26-116F 
3S= One Low Head 115 Volt Pump, Grundfos UP26-99F 
4S= Two Low Head 115 Volt Pump, Grundfos UP26-99F 
YY= None
Code 27= Coaxial Coil Supply Liquid Flow Control 
B= 2-Way, Motorized- 24V Valve Control, NO 
C= 2-Way, Motorized- 24V Valve Control, NC 
Y= None
Code 28= Coaxial Coil Supply Liquid Auto Flow Reg 
A= 1.5 GPM 
B= 2.0 GPM 
C= 2.5 GPM 
D= 3.0 GPM 
Y= None
Code 29= Coaxial Coil Supply Liquid Strianer 
Y= None 
Code 30= Always Y
Code 31= Desuperheater Water Flow Options 
Q= Pump 208-230/60/1V 
Y= None
Code 45= Insulation- Piping 
A= Insulated Piping 
Y= None
Code 46= Always Y
Code 47= Cabinet Finish 
A= Powder Coat 
G= Galvanized Steel
Code 48= Cabinet Color 
T= Textured Charcoal Bronze 
W= Off White 
Y= None
Code 49= Always Y
Code 50= Fan Motor Control 
C= Various Speeds with 4 Adjustment Settings
Code 51= Fan Motor Control location 
Y= None
Code 52= Always YY
Code 53= Disconnect Switch 
N= Non-Fused 
Y= None
Code 54= Always Y
Continued on next page.
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 5
 
Page 6
Nomenclature
Code 55= Control Transformer 
1= 50VA 
2= 75VA
Code 56= Thermostat/Sensor Control 
S= Sensor Control 
T= Thermostat Control
Code 57= Currrent Sensing Switches 
Y= None
Code 58= Condensate Overflow Protection 
S= Sensor 
Code 59= High Pressure Switch 
A= 600 psi NC 
Code 60= Low Pressure Switch or Sensor 
L= 7 psi NC 
Code 61= Low Temp. Protection Compressor Suction 
K= 10K Thermistor
Code 62= Discharge Air Thermistor 
K= 10K Thermistor 
Y= None
Code 63= Leaving Supply Fluid Temp 
K= 10K Thermistor 
Y= None
Code 64= Entering Supply Fluid Temp 
K= 10K Thermistor 
Y= None
Code 65= Return Air Thermistor 
K= 10K Thermistor 
Y= None
Code 66-67 = Always YY
Code 68= Terminal Block Connection 
Y= None
Code 69= Emergency Switch for Electric Heat 
Y= None
Code 70= Annunciator 
A= Yes
Code 71= Reset Button 
Y= None 
Code 72 = Monitoring 
Y= None
Code 74= External Binary Output 1 
Y= None 
Code 75= Expansion Device 
A= Thermal Exp. Valve Thermal Bulb & Equalizer Tube
Code 76= Alarm Relay 
A= Alarm Relay (Dry Contacts) 
Y= None
Code 77= Dirty Filter Sensor 
Y= None
Code 78= Reversing Valve 
C= Normally Open in Cooling Mode
Code 79= Outside Air Control 
Y= None
Code 80= Always Y
Code 81= Boilerless Electric Heat Setpoint 
GL= Glycol 28F 
WA= Water 55F 
YY= None
Code 82= Freeze Fault Protection 
FF= Freeze Fault Protection 
YY= None
Code 83= Occupied Setpoint Differential (1-5F) 
ST= Setpoint (1˚F)
Code 84= Unoccupied Setpoint Differential (2-10F) 
ST= Setpoint (2˚F)
Code 85= Hydronic Heating on Setpoint (70-90F) 
YY= None
Code 86= BACnet Address 
YYY= None
Code 87= Always Y
Code 88= Agency 
C= ETL, CETL, ARI
Code 89= Conformance 
Y= None
Code 90= Always Y
Code 91= Extended Warranty
Code 92= Product Style
Code 73= Emergency Stop 
Y= None
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 6
 
Page 7
Electrical Legend
AN1, 2 ........................ LED/Annunciator Circuit 1, 2 
C01 - 04 ..................... Fan Motor, Capacitor 1-4 
C11 - 12 ..................... Capacitor, Compressor
CP1, 2 ........................ Compressor 1, 2
COS ........................... Condensate Overflow Sensor
DAT ............................ Discharge Air Temp Sensor
EWT ........................... Entering Water Temp Sensor
HP1, 2 ........................ High Pressure Switch 1, 2
ISO ............................ Water Flow Isolation Valve Actuator
LT1, 2 ......................... Suction Line Temp Sensor 1, 2
LWT ........................... Leaving Water Temp Sensor
MCB ........................... Main Control Board
NCB ........................... Network Control Board
RAT ............................ Return Air Temp Sensor
RV1, 2 ........................Reversing Valve 1, 2
TR1 ............................ Transformer, Control
TR2 ............................ Transformer, Fan Motor
TR3 ............................ Transformer, Loop Pump
WSE .......................... Water Side Economizer Actuator
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 7
 
Page 8
Typical Refrigeration Cycles
Cooling Refrigeration Cycle (single circuit only shown)
Return Air
Thermal
 Expansion Valve
Co-Axial Heat
 Exchanger
Coil- Air to Refrigerant 
Heat Exchanger
Blower
Heating Refrigeration Cycle (single circuit only shown)
Conditioned Air (Cooling)
Return Air
Thermal
 Expansion Valve
Water In
Water Out
Sensing Bulb & 
Capillary Tube
Compressor
Reversing Valve
Co-Axial Heat
 Exchanger
Coil- Air to Refrigerant 
Heat Exchanger
Blower
Reversing Valve
Conditioned Air (Heating)
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 8
Water In
Water Out
Sensing Bulb & 
Capillary Tube
Compressor
 
Page 9
375
300
Blower Fan Assembly
350
355
310
 Ref.         Part            
 No. Description      Number   007   009   012
 300  ECM Motor, 115/60/1 * 
      1/10 HP     910127701   1 
      1/10 HP     910127702      1 
      1/10 HP     910127703         1 
 300 ECM Motor, 208-230/60/1 *  
      1/10 HP     910127704   1 
        1/10 HP     910127705      1 
        1/10 HP     910127706         1
 310 Inlet Ring      060629101   1   1   1  
 350  Fan Housing      060699602   1   1   1 
 355 Wheel, Blower Fan      910123343   1   1   1   
 N/S Grommet- Motor Mount      910126826   3   3   3  
 N/S Grommet- Motor Mount      910126827   3   3   3
 375 Bracket- Motor Mount      668122101   1   1   1
* Check the name plate to verify program. Fan motors are shipped programmed.
Unit Sizes
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 9
 
Page 10
Refrigeration Circuit
Components
  Ref.         Part            
 No. Description      Number   007   009   012
 N/S Hex Nut, Compr. Mounting      802012035   3   3   3  
 N/S Grommet, Compr. Mounting      668955401   3   3   3 
 N/S Sleeve, Compr. Mounting      668955501   3   3   3
 N/S Compressor, 6450 BTUH   115/60/1   668803001   1 
      Compressor, 8050 BTUH   115/60/1   668951401      1 
      Compressor, 10150 BTUH   115/60/1   668951504         1 
      Compressor, 6400 BTUH   208-230/60/1   668803011   1 
      Compressor, 8050 BTUH   208-230/60/1   668951411      1 
      Compressor, 10150 BTUH   208-230/60/1   668951501         1 
      Compressor, 6350 BTUH   265/60/1   668803021   1 
      Compressor, 8150 BTUH   265/60/1   668951412      1 
      Compressor, 8150 BTUH   265/60/1   668951503         1 
 N/S Overload Protector   115/60/1   668015811   1 
      Overload Protector   115/60/1   668015802      1   1 
      Overload Protector   208-230/60/1   668015816   1      1 
      Overload Protector   208-230/60/1   668015804      1 
      Overload Protector   208-230/60/1   668015806         1 
      Overload Protector   265/60/1   668015814   1 
      Overload Protector   265/60/1   668015805      1   1
 N/S Compressor Terminal Components  
      Terminal Cover      668382801   1   1   1 
      Gasket      668382701   1   1   1 
      Gasket      668382901   1   1   1 
      Nut      668383001   1   1   1
Unit Sizes
 N/S Condenser   Copper Inner Tube (C15=C)   668182501   1   1   1 
 N/S Adapter   .500 x .625 ODS   106474901   1   1   1 
 N/S Evaporator Coil   LH   669952019   1   1   1 
      Evaporator Coil    RH   669952017   1   1   1 
 N/S Reversing Valve   2T   910124937   1   1 
      Reversing Valve   2T   910124938         1 
 N/S Solenoid- Reversing Valve      106694207   1   1   1
 N/S High Pressure Switch      910117560   1   1   1 
      Low Pressure Switch      107225101   1   1   1 
      Seat, Fitting      668188801   1   1   1 
 N/S Core, Valve      668188701   1   1   1 
 N/S Cap, Valve      668189501   1   1   1 
 N/S  Fusible Plug Assy      850008345   1   1   1  
       Plug Only   283° F   106057401   1   1   1 
 N/S Thermal Expansion Valve, TXV   1/2T   910122533   1 
      Thermal Expansion Valve, TXV   1T   910122531      1 
      Thermal Expansion Valve, TXV   1T   910120987         1 
 N/S Condensate Pan, SSTL   Horizontal   669972212   1   1   1 
      Condensate Pan, SSTL    Vertical   669972211   1   1   1
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 10
 
Page 11
Refrigeration Circuit
Components
Base Pan
 Ref. Description    Char Bronze   Off White    
 No.        Textured Pwd   Pwd   Galv.
 N/S Base Pan, Horizontal   LH   669942514      669942207  
         RH   669942507   669942520 669942205
 N/S   Base Pan, Vertical      669942511      669942206
Water Flow Control
  Ref.         Part            
 No. Description      Number   007   009   012
 N/S Auto Flow Control Valve   1.5 GPM   113133703   1    
 N/S Auto Flow Control Valve   2.0 GPM   669648901   1   1 
      Auto Flow Control Valve   2.5 GPM   669648902      1   1 
      Auto Flow Control Valve   3.0 GPM   669648903         1
Unit Sizes
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 11
 
Page 12
Control Box
Components
  Ref.         Part            
  No.  Description    Number 007 009 012
Unit Sizes
  N/S  Bracket,  Capacitor     850010570  1 1 1 
 N/S Capacitor, 265/60/1   20MFD 440VAC   910120047   1   1   1 
      Capacitor, 208-230/60/1   25MFD 440VAC   910120048   1   1   1 
      Capacitor, 208-230/60/1   30MFD 440VAC   910120049   1   1   1 
      Capacitor, 115/60/1   45MFD  440  VAC  910120052  1 1 1 
 N/S MicroTech III Control Board, Series 2      250806500   1   1   1  
 N/S I/O Expansion Board Assy, Series 2      250806601   1   1   1  
 N/S Fan Speed Selection Board Assy      668917201   1   1   1  
 N/S LED Annunciator Assy      668395201   2   2   2 
 N/S LonWorks Comm. Card with Software      250806801   1   1   1 
 N/S BACnet Comm. Card with Software      250806701   1   1   1 
 N/S Stand Off 
    PC  Board     802028115  8 8 8 
      Edge- Holders   Comm. Card only   910105356   5   5   5
 N/S H1 Connector, 2-Pin   (24V Power)    4EGA9159  1 1 1
 N/S H2 Connector, 2-Pin/1-Blank   (Fan Output)   4EGA9160  1 1 1   
 N/S H3 Connector, 2-Pin   (Hi Pressure Switch)    668302122  1 1 1  
 N/S H4 Connector, 4-Pin   (Dis Air/Leaving H  
O Temp Sensor)   668302122  3 3 3 
2
 N/S H6 Connector, 7-Pin   (Cond OF/Low P/Low T/Rev Vlv)   4EGA9164  1 1 1  
 N/S H8 Connector, 3-Pin   (Motorized & Iso Vlvs/Pump Relay)    4EGA9160  1 1 1  
 N/S H9 Connector, 2-Pin   (RA Temp Sensor)   4EGA9160  1 1 1   
  N/S  Rocker  Switch     061350601  1 1 1 
 N/S Contactor, Compressor   24V 2PDT   073300101   1   1   1  
 N/S Disconnect Switch, 3P, 63A      910123457   1   1   1
  N/S  Transformer,  50VA   115V  910116204  1 1 1 
      Transformer, 75VA   115V   910117810   1   1   1 
      Transformer, 50VA   208/230V   910116202   1   1   1 
      Transformer, 75VA   208/230V   910116213   1   1   1 
      Transformer, 50VA   265V   910116203   1   1   1 
      Transformer, 75VA   265V   910116209   1   1   1 
      Transformer, Fan Motor, 250VA   265/115V   668917705   1   1   1
 N/S Suction Line Temp Sensor, (LT)- .36" Dia   10K   910121229   1   1   1 
     Suction Line Temp Sensor, (LT)- .5" Dia   10K   910121227   1   1   1
      Suction Line Temp Sensor, (LT)- .625" Dia   10K   910121230   1   1   1 
 N/S Sensor, Temp, Discharge Air (DAT)   10K/72”   910106325   1   1   1   
 N/S Sensor, Temp, Return Air (RAT)   10K/72”   910106325   1   1   1   
 N/S Sensor, Temp, Entering Water (EWT), .61" Dia  10K/80”   910121230      1   1  
 N/S Sensor, Temp, Leaving Water (LWT), .61" Dia   10K/80”   910121230      1   1 
 N/S Sensor, Temp, Entering Water (EWT), 1.12" Dia 10K/80”   107201601   1   1   1
 N/S Sensor, Temp, Leaving Water (LWT), 1.12" Dia 10K/80”   107201601   1   1   1 
N/S= Not shown on diagram. 
*  Used on any unit with the following applications: 2 Compressors/Stages, Supplemental Electric Heat, Multi-speed ECM Motors, and Hot Gas Bypass. 
** Field-upgrading requires a Service Tool for com. card programming, com-card stand-off & main PCB jumper change. 
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 12
 
Page 13
Field Installed Accessories
Filters
D escription    Horizontal    Vertical 
 Kit, Filter, 2" Throwaway      910127257   910121691 
  12 Pack of 2" Filter Throwaway      910129103   910129097
 Kit, Filter, 2" MERV 8 Throwaway      910127259   910123767 
  12 Pack of 2"MERV 8 Throwaway      910129114   910129108
 Kit, Filter, 4" MERV 13 Throwaway      910127260   910123768 
  6 Pack of 4" MERV 13 Throwaway      910129125   910129119
Unit Hanger
 Description 
 Unit Hanger Kit  1 
  Unit Sizes 026-072   669997602 
1
 Kit includes four (4) brackets (p/n 669823200), four (4) grommets (p/n 802003334), and hardware.
Part Number
Thermostats
D escription    Part Number 
 Programmable TStat - 3 Cool-4 Heat, built-in humidity sensing, ACO and 7-day.      910121750  
 Remote Room Sensor, Indoor (Used with T'Stat 910121750)       910129095  
 Remote Room Sensor, Outdoor (Used with T'Stat 910121750)       910129096  
 Non-Programmable TStat - 2 Cool-2 Heat, ACO & MCO.      910121746  
 Programmable TStat - 2 Cool-2 Heat, ACO & MCO and 7-day.      910121748  
 Remote Room Sensor, Indoor (Used with T'Stat  910121746 & 910121748 )    667720401
Thermostat Accessory Kits
 Description 
 T'Stat Guard   105571101 
    10 Pack   105571110
Part Number
 Wall Plate   107096101
MTIII Communication Module Kits
 Description 
 LonWorks Comm Module   910128888 
 BacNet Comm Module   910128889 
 Wire Harness Assy Kit for MicroTech III (H8, ISO Valve, & Actuator)   910107989
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 13
Part Number
 
Page 14
Field Installed Accessories
Ball Valve
 Description   
 Combination Shutoff/Balancing Valve with Memory Stop (2/unit) 
 Ball Valve, 1/2" FPT    802026097 106065102    106065110
Motorized Water Valve
 Description    Kit Actuator Body  
 Motorized  Valve Kit, 1/2” Sweat, Normally Closed (NC)    4.9Cv  910131359  910129596 910129293 
  Motorized Valve Kit, 1/2” NPT, Normally Closed (NC)     4.9Cv 910131353 910129596 910129296     
  Motorized Valve Kit, 1/2” Sweat, Normally Open (NO)    4.9Cv 910131356    910129599 910129293     
  Motorized Valve Kit, 1/2” NPT, Normally Open (NO)    4.9Cv 910128986  910129599 910129296    
Waterside Economizer
Part No.
   2 Pack   10 Pack
D escription    Part Number 
 3-Way Valve, 1/2”      107179701    
 Actuator    107179809  
 Valve, Air Manual  107264801 
Hoses
Description   Specification Part Number 
Hose Assy, Fire Rated Condensate   3/4" NPT X 2'   106063801 
    3/4" NPT X 3'   106063901 
 Hose Assy, Fire Rated Supply/Return (2 Pack)   1/2" NPT X 2'   106062801 
    1/2" NPT X 3'   106063101 
    3/4" NPT X 2'   106062901 
    3/4" NPT X 3'   106063201 
    1" NPT X 2'   106063401 
    1" NPT X 3'   106063501
 Hose Assy, Plastic Condensate   3/4" NPT  X 30"   106063701
    3/4" NPT X 36"   106665101 
 1/2" Flow Control Hose Kit, Fire Rated Supply/Return   0.5 GPM   106582901 
 Includes: Supply Ball Valve, Y-Strainer, and 24" Stainless Steel Hose.   1.0 GPM   106582902 
 Return Flow Controller, Ball Valve, (2) P/T, 24" Stainless Steel Hose.   1.5 GPM   106582903
    2.0 GPM   106582904
    2.5 GPM   106582905
    3.0 GPM   106582906
    3.5 GPM   106582907
    4.0 GPM   106582908
    4.5 GPM   106582909
    5.0 GPM   106582910
5.5 GPM   106582911
6.0 GPM   106582912
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 14
 
Page 15
Field Installed Accessories
Continued
MicroTech III Temperature Sensors
   Part No.   Tenant Override   Set Point Adjustment   Status LED   Fan & Mode Switches
 669529001   Yes   No   No   No 
 669529101   Yes   55˚ to 95˚F (12˚ to 35˚C)   Yes   Yes 
 669529201   Yes   -3˚ to +3˚F (-1.5˚ to 1.5˚C)   No   Yes
Note: Can only be used in conjunction with a communication (Comm.) card. See OM 931 for required jumper settings.
MicroTech III Unit Control Accessories
Description      Part Number 
** Multiple Unit Control Panel: 
             Allows a master unit controlled by a T'Stat, to operate up to 3 secondary units 
             Not Recommended for use with a Boilerless System Kit
 Boilerless System Kit      0062522201 
 Boilerless System Kit with I/O Expansion Board      910110355 
 Boilerless System Kit without I/O Expansion Board      910110353 
 Programmmable Sensor for BACnet/LON- 3 Cool-4 Heat w/ built-in humidity sensing   910121754 
 Sensor for BACnet/LON- 2 Cool-2 Heat w/Warm-Cooler Temp Adj.      910121753
** Kit components listed below
056794201
Multiple Unit Control Panel Kit
310
WSHP; WGSH/WGSV 007- 012 Design 1                New  8/12                        RPL 700024700 / Page 15
311
313
 Ref. Description   Part No.   Qty. 
 No.  
 310 Cover, Control Box   106436101   1 
 311 Circuit Board   056794001   1 
 312 Stand Off, Circuit Board   802028090   6 
 313 Box   850007827   1
312
 
Page 16
Critical Daikin McQuay OEM Parts Are What Your
Daikin McQuay HVAC Unit Needs!
SmartSourceTM Single Stage WSHP
WGSH, WGSV
 Sizes 007 - 012 
Design 1
CRITICAL            PART 
COMPONENTS      MODEL   UNIT SIZE   VOLTAGE   NUMBER 
CONTROLS          
 MicroTech III Control Board, Series 2      ALL   ALL   N/A   250806500 
 I/O Expansion Board Assy, Series 2      ALL   ALL   N/A   250806601 
  LonWorks Comm. Card & Software    ALL   ALL   N/A   250806801   
 BACnet Comm. Card & Software     ALL   ALL   N/A   250806701
COMPRESSOR          
 6450 BTUH        ALL 007 115/60/1 668803001 
 8050 0 BTUH       ALL 009 115/60/1 668951401  
 10150 BTUH        ALL 012 115/60/1 668951504  
 6400 BTUH         ALL 007 208-230/60/1 668803011  
 80500 BTUH        ALL 009 208-230/60/1 668951411  
 10150 BTUH        ALL 012 208-230/60/1 668951501  
 6350 BTUH         ALL 007 265/60/1 668803021 
 8150 BTUH        ALL 009 265/60/1 668951412   
 10150 BTUH        ALL 012 265/60/1 668951503  
BLOWER FAN MOTOR             
 1/10HP      ALL   007   115/60/1   910127701  
 1/10HP      ALL   009   115/60/1   910127702  
 1/10HP      ALL   012   115/60/1   910127703  
 1/10HP      ALL   007   208-230/60/1   910127704  
 1/10HP      ALL   009   208-230/60/1   910127705  
 1/10HP      ALL   012   208-230/60/1   910127706 
BLOWER FAN ASSY          
 Blower Fan Housing      ALL   ALL   ALL   060699602 
 Blower Fan Wheel      ALL   ALL   ALL   910123343
REFRIGERATION CIRCUIT          
 Reversing Valve      ALL   007, 009   N/A   910124937 
 Reversing Valve      ALL   012   N/A   910124938 
 Reversing Valve      ALL   019   N/A   106694112 
 Solenoid-Reversing Valve      ALL   ALL   N/A   106694207 
 Thermal  Expansion Valve   1/2 Ton   ALL   007   N/A   910122533 
 Thermal  Expansion Valve   1 Ton   ALL   009   N/A   910122531 
 Thermal  Expansion Valve   1 Ton   ALL   012   N/A   910120987
SENSOR          
 Discharge Air Sensor (DAT)    10K/72"   ALL   ALL   N/A   910106325 
 Return Air Sensor (RAT)   10K/72"    ALL   ALL   N/A   910106325 
 Entering Water Sensor (EWT)-.62"   10K/80"    ALL   009, 012   N/A   910121230 
 Leaving Water Sensor (LWT)-.62"   10K/80"    ALL   009, 012   N/A   910121230 
 Entering Water Sensor (EWT)-1.12"   10K/80"    ALL   ALL   N/A   107201601 
 Leaving Water Sensor (LWT)-1.12"   10K/80"    ALL   ALL   N/A   107201601
Call Your Local Daikin McQuay Parts Distributor For All Your Parts Needs.
To Locate A Distributor, Go To www.DaikinMcQuay.com or Call 1-800-37PARTS
7000247 New 8/2012               CPL Page 1 of 1