McQuay WCA036 User Manual

McQuay Water to Water Source Heat Pumps Catalog 1107
Model WRA, WHA, WCA
Unit Sizes 036 – 420 • R-410A Refrigerant
Engineered for exibility and performance™
Contents
Nomenclature.....................................................................3
WRA, WHA, WCA
Electrical Data ....................................................................5
Capacity Data ................................................................6-27
WRA, WCA – Size 036 Cooling ..................................... 6
WRA, WHA – Size 036 Heating ..................................... 7
WRA, WCA – Size 048 Cooling ..................................... 8
WRA, WHA – Size 048 Heating ..................................... 9
WRA, WCA – Size 060 Cooling ................................... 10
WRA, WHA – Size 048 Heating ................................... 11
WRA, WCA – Size 072 Cooling ................................... 12
WRA, WHA – Size 072 Heating ................................... 13
WRA, WCA – Size 120 Cooling ................................... 14
WRA, WHA – Size 120 Heating ................................... 15
WRA, WCA – Size 150 Cooling ................................... 16
WRA, WHA – Size 150 Heating ................................... 17
WRA, WCA – Size 180 Cooling ................................... 18
WRA, WHA – Size 180 Heating ................................... 19
WRA, WCA – Size 240 Cooling ................................... 20
WRA, WHA – Size 240 Heating ................................... 21
WRA, WCA – Size 300 Cooling ................................... 22
WRA, WHA – Size 300 Heating ................................... 23
WRA, WCA – Size 360 Cooling ................................... 24
WRA, WHA – Size 360 Heating ................................... 25
WRA, WCA – Size 420 Cooling ................................... 26
WRA, WHA – Size 420 Heating ................................... 27
Design Features
.....................................4
WRA, WCA, WHA Physical Data ....................................28
WRA, WCA, WHA Correction Factors ............................28
Dimensional Data .......................................................29-31
WRA, WCA, WHA – Size 036–072 .............................. 29
WRA, WCA, WHA – Size 120–38 ................................ 30
WRA, WCA, WHA – Size 240–420 .............................. 31
Engineering Guide Specications ................................. 32
“McQuay” is a registered trademark of McQuay International.
©McQuay International 2010. All rights reserved throughout the world.
The information in this catalog supersedes and replaces previous catalogs with regard to McQuay Terminal Air Conditioning products. Illustrations cover the general ap-
Page 2 of 32 CAT 1107
McQuay R-410A Water to Water Source Heat Pumps
McQuay WSHP Product Model Nomenclature
W WRA 1 036 E F T F YY FS A C Y A PVM
Product Category
W = WSHP
Product Identier
WRA = Heating and Cooling Models WHA = Heating Only Models WCA = Cooling Only Models
Design Series
1 = 1st Design 2 = 2nd Design 3 = 3rd Design 4 = 4th Design
Nominal Capacity
036 = 36,000 Btuh Nominal Cooling 048 = 48,000 Btuh Nominal Cooling 060 = 60,000 Btuh Nominal Cooling 072 = 72,000 Btuh Nominal Cooling 120 = 120,000 Btuh Nominal Cooling 150 = 150,000 Btuh Nominal Cooling 180 = 180,000 Btuh Nominal Cooling 240 = 240,000 Btuh Nominal Cooling 300 = 300,000 Btuh Nominal Cooling 360 = 360,000 Btuh Nominal Cooling 420 = 420,000 Btuh Nominal Cooling
Controls
E = Electromechanical T = Temperature Control System
Voltage
E = 208-230/60/1 F = 208-230/60/3 K = 460/60/3 L = 575/60/3
Source Water to Refrigerant Heat Exchanger Construction
C = Copper Inner Tube ­ Steel Outer Tube S = Cupro-Nickel Inner Tube ­ Steel Outer Tube Y = None
Construction Type
A = Standard
Refrigerant
A = R-410A
Desuperheater
Y = None D = Waste Heat Recovery Water Heater
Cabinet Electrical
YYY = None PVM = Phase Monitor Monitors Voltage and Phase Loss
Water Piping Location
F = Front T = Top L = Left Hand Side R = Right Hand Side
Status Lights
YY = None SL = Three Lights-Compressor-1, Compressor-2, Compressor fault
Control Box Location
F = Front L = Left Side Control Box R = Right Side Control Box
NOTE: For illustration purposes only. Not all options available with all models.
PleaseconsultyourlocalMcQuayRepresentativeforspecicavailability.
Freezestat
YY = None FS = Adjustable for Geothermal and Boiler/Tower Application
Model WRA
CAT 1107 Page 3 of 32
Design Features
Model WRA, WHA, WCA
R-410A High Efciency Water to Water Source Heat Pumps
Model WRA - Heating and Cooling Unit – 60Hz Standard Design Features:
■ PaintFinishmeetsorexceeds1,000hourSalt
Spray Test per ASTM B117 97.
■ 1/2"high-densityberglassinsulationforthermal
and sound insulation.
■ Serviceconnections
factory installed in compressor suction and discharge lines for ease of servicing.
■ Bi-owThermal  ExpansionValve(TXV)
for precise metering of
refrigerantowunder
all expected operating conditions.
■ Highefciencycoaxial
water-to-refrigerant coils, fully insulated with polyurethane foam to maximize performance while helping to prevent condensate build-up in unit base pan.
■ Highpressureandlowpressureequipment
protection built into the source side refrigeration circuit to guard against abnormal unit operation.
■ Fullyinsulatedrefrigerantandwaterlinesto
help prevent condensation from collecting in the unit base.
■ Highefciencyscrollcompressors
Optional Features:
■ TemperatureControlSystem(sizes120through
420) – Controls return water temperature and has
aseparatesetpointforheatingandcooling(1–2  stages).Requiresaeldsuppliedsignalfor
heat/cool changeover.
■ AdjustableFreezestatforgeothermalandboiler
tower applications. Senses leaving water on the source side and will shut down the unit if below setpoint.
■ ThreeLightStatusPanel(sizes120through420)–
Compressor 1 “ON”, compressor 2 “ON” and “compressor fault” lights located outside unit.
■ SourceSideCoaxialWaterCoil–Singlewall
cupro-nickel inner tube coaxial heat exchanger.
■ Phase/VoltageMonitor(3phaseonly)–Monitors
main power for low voltage, high voltage or phase loss.
R-410A Refrigerant – No Ozone Depletion Potential with no phase out date.
■ HeatRecoveryCoilForDomesticWaterHeating  (models036-072)–Specialheatrecovery  (desuperheater)coilispipedintothecompressor
discharge line. Domestic water connections are 1/2" female pipe threads.
■ 24-voltelectromechanicalcontrolsystem.
■ Threadedcopperttingsoutsidethecabinetallow
for load and source piping connection.
Page 4 of 32 CAT 1107
Table 1.
Unit Size
036
048
060
072
120
150
180
240
300
360
420
Electrical Data – WRA, WHA, WCA 036 – 420
Compressor Total Min./Max. Min. Circuit Max. Circuit Max. Fuse
Voltage-Hz-Phase
208-230/60/1 208-230/60/3
460/60/3
575/60/3 208-230/60/1 208-230/60/3
460/60/3
575/60/3 208-230/60/1 208-230/60/3
460/60/3
575/60/3 208-230/60/3
460/60/3
575/60/3 208-230/60/3
460/60/3
575/60/3 208-230/60/3
460/60/3
575/60/3 208-230/60/3
460/60/3
575/60/3 208-230/60/3
460/60/3
575/60/3 208-230/60/3
460/60/3
575/60/3 208-230/60/3
460/50/3
575/60/3 208-230/60/3
460/60/3
575/60/3
RLA (each) LRA (each)
16.7
10.4
5.8
3.8
23.1
16.1
7.1
5.6
30.2
20.6
9.7
7.7
22.5
10.6
7.7
20.1
9.7
7.7
22.5
10.6
7.7 25
12.2 9
30.2
16.7
12.2
48.1
18.6
14.8
51.3
22.5
19.9
55.8
27
23.8
79 73 38
36.5 134
91 46
37 158 155
75
54 149
75
54 155
75
54 149
75
54 164 100
78 225 114
80 245 125 100 300 150 109 340 173 132
Amps Volts Ampacity Breaker Size
16.7
10.4
5.8
3.8
23.1
16.1
7.1
5.6
30.2
20.6
9.7
7.7
22.5
10.6
7.7
40.2
19.4
15.4 45
21.2
15.4 50
24.4 18
60.4
33.4
24.4
96.2
37.2
29.6
102.6 45
39.8
111.6 54
47.6
197/253 187/253 414/506 517/632 197/253 187/253 414/506 517/632 197/253 187/253 414/506 517/632 187/253 414/506 517/632 187/253 414/506 517/632 187/253 414/506 517/632 187/253 414/506 517/632 187/253 414/506 517/632 187/253 414/506 517/632 187/253 414/506 517/632 187/253 414/506 517/632
20.9 13
7.3
4.8
28.9
20.1
8.9 7
37.8
25.8
12.1
9.6
28.1
13.3
9.6
46.4
21.8
17.3
50.6
23.9
17.3
56.3
27.5
20.3 68
37.6
27.5
108.2
41.9
33.3
115.4
50.6
44.8
125.6
60.8
53.6
35 20 15 15 50 35 15 15 60 45 20 15 50 20 15 60 30 25 70 30 25 80 35 25 90 50 35
150
60 45
150
70 60
175
80 70
35 20 15 15 50 35 15 15 60 45 20 15 50 20 15 60 30 25 70 30 25 80 35 25 90 50 35
150
60 45
150
70 60
175
80 70
CAT 1107 Page 5 of 32
Capacity Data – WRA, WCA 036 – Cooling
EWT GPM WPD EWT GPM LWT WPD
40
50
70
85
90
100
110
Source
7.5
9.0
7.5
9.0
7.5
9.0
7.5
9.0
7.5
9.0
7.5
9.0
9.0
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
16.8
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
50
7.5
9.0
7.5
9.0
7.5
9.0
Load
40.1
41.6
44.4
46.0
48.6
50.3
40.1
41.6
44.3
46.0
48.5
50.3
40.8
42.2
45.1
46.6
49.4
51.0
40.8
42.2
45.1
46.6
49.3
51.0
41.6
42.9
45.9
47.3
50.3
51.8
41.5
42.9
45.9
47.3
50.2
51.7
42.2
43.4
46.6
47.9
50.9
52.4
42.1
43.4
46.5
47.8
50.9
52.3
42.4
43.6
46.8
48.1
51.2
52.5
42.3
43.5
46.7
48.0
51.1
52.5
42.7
43.9
47.2
48.4
51.6
52.9
42.7
43.8
47.1
48.4
51.5
52.8
43.1
44.2
47.5
48.7
51.9
53.2
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
CAT 1107 Page 6 of 32
Capacity
Btu/h
36,885 37,433 39,709 40,325 42,654 43,343 38,520 39,096 41,481 42,130 44,571 45,297 37,784 38,329 40,665 41,277 43,668 44,354 37,479 38,023 40,348 40,960 43,341 44,027 33,327 33,779 35,866 36,375 38,512 39,081 35,270 35,752 37,967 38,510 40,779 41,387 33,080 33,509 35,622 36,103 38,269 38,808 31,468 31,880 33,895 34,357 36,423 36,941 30,602 30,993 32,965 33,404 35,426 35,917 30,790 31,187 33,176 33,621 35,661 36,160 28,700 29,056 30,948 31,347 33,287 33,734 27,869 28,217 30,057 30,449 32,337 32,775 26,249 26,567 28,352 28,710 30,540 30,941
Rejection
Heat of
Btu/h
41,234 41,776 44,032 44,642 46,952 47,636 43,610 44,188 46,582 47,232 49,685 50,415 45,307 45,877 48,323 48,964 51,470 52,188 43,709 44,263 46,630 47,254 49,680 50,380 38,702 39,142 41,174 41,669 43,752 44,306 43,481 43,980 46,271 46,832 49,181 49,809 44,275 44,736 47,010 47,529 49,861 50,441 39,535 39,951 41,988 42,456 44,546 45,070 39,119 39,514 41,508 41,952 43,997 44,493 39,576 39,980 42,004 42,458 44,534 45,042 38,760 39,126 41,072 41,483 43,478 43,938 37,186 37,541 39,413 39,812 41,733 42,179 36,863 37,189 39,017 39,384 41,258 41,669
Watts
1,413 1,417 1,438 1,443 1,465 1,471 1,489 1,494 1,515 1,520 1,542 1,548 1,642 1,647 1,669 1,675 1,698 1,705 1,668 1,673 1,695 1,700 1,723 1,729 2,022 2,027 2,050 2,056 2,080 2,086 2,083 2,087 2,110 2,116 2,139 2,146 2,480 2,485 2,509 2,515 2,541 2,547 2,486 2,490 2,514 2,519 2,543 2,549 2,677 2,682 2,707 2,713 2,739 2,746 2,650 2,654 2,678 2,683 2,708 2,714 3,046 3,051 3,077 3,083 3,110 3,116 2,996 3,001 3,024 3,029 3,054 3,060 3,384 3,388 3,412 3,417 3,442 3,447
Source
LWT
51.6
51.8
52.4
52.6
53.2
53.4
49.7
49.8
50.3
50.5
51.0
51.2
61.0
61.1
61.7
61.9
62.5
62.7
59.2
59.3
59.8
59.9
60.4
60.6
80.5
80.6
81.2
81.3
81.9
82.0
78.8
78.9
79.3
79.4
79.9
80.0
95.2
95.3
95.8
95.9
96.5
96.6
93.5
93.6
94.0
94.1
94.6
94.7
100.1
100.2
100.7
100.8
101.4
101.5
98.4
98.5
98.9
99.0
99.5
99.6
110.0
110.1
110.6
110.7
111.2
111.3
108.3
108.4
108.8
108.9
109.4
109.5
118.3
118.4
118.8
118.8
119.3
119.4
Capacity Data – WRA, WHA 036 – Heating
EWT GPM EWT GPM LWT WPD
30
40
50
70
85
Notes:
1. Heating Data in BOLD = Freeze protection of the source loop is required.
2. Alldataisbasedon100%waterastheheattransferuid.
3. Apply capacity correction factors based on the percent anti-freeze mixture.
4. Do not select units above 120°F leaving water temperature for the load in the heating mode or below 40°F for the load in the cooling mode.
5. Capacity - Btuh produced by the load loop.
6. Load - water loop serving the air handler or terminal device.
7. Source - heat rejection water loop; geothermal or boiler/tower loop.
EWT = Entering water temperature, °F
GPM=Gallonsperminuteow
WPD = Water pressure drop, ft. of water Btu/h = Btu per hour of heat transfer LWT = Leaving water temperature, °F
Source
7.5
9.0
7.5
9.0
7.5
9.0
7.5
9.0
7.5
9.0
100
110
100
110
100
110
100
110
100
110
100
110
100
110
100
110
100
110
100
110
90
7.5
9.0
7.5
9.0
7.5
9.0
90
7.5
9.0
7.5
9.0
7.5
9.0
90
7.5
9.0
7.5
9.0
7.5
9.0
90
7.5
9.0
7.5
9.0
7.5
9.0
90
7.5
9.0
7.5
9.0
7.5
9.0
90
7.5
9.0
7.5
9.0
7.5
9.0
90
7.5
9.0
7.5
9.0
7.5
9.0
90
7.5
9.0
7.5
9.0
7.5
9.0
90
7.5
9.0
7.5
9.0
7.5
9.0
90
7.5
9.0
7.5
9.0
7.5
9.0
Load
97.7
96.4
107.6
106.4
117.6
116.3
97.7
96.4
107.7
106.4
117.6
116.3
98.8
97.3
108.7
107.3
118.6
117.2
98.8
97.4
108.8
107.3
118.7
117.2
100.0
98.3
109.9
108.2
119.8
118.2
100.1
98.4
110.0
108.3
119.9
118.2
102.8
100.6
112.6
110.5
122.4
120.3
102.9
100.8
112.7
110.6
122.5
120.4
105.2
102.7
115.0
112.5
124.7
122.3
105.4
102.9
115.1
112.7
124.9
122.4
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
11.7
16.8
Capacity
Btu/h
29,416 29,424 29,243 29,257 29,003 29,020 34,116 34,127 33,901 33,918 33,609 33,630 33,892 33,909 33,636 33,656 33,341 33,363 34,692 34,711 34,413 34,436 34,096 34,121
38,093 38,124 37,720 37,752 37,337 37,369 39,726 39,760 39,315 39,351 38,896 38,931 49,100 49,180 48,375 48,451 47,696 47,765 48,882 48,967 48,127 48,207 47,419 47,494 56,998 57,139 55,958 56,088 54,998 55,115 58,214 58,366 57,107 57,247 56,084 56,210
Heat of
Absorbtion
21,578 21,651 20,363 20,447 18,991 19,084 20,657 20,728 19,489 19,571 18,172 18,262 25,692 25,786 24,356 24,461 22,881 22,994 26,239 26,337 24,867 24,975 23,355 23,471
Btu/h
30,548 30,670 29,046 29,178 27,421 27,561 30,845 30,971 29,318 29,453 27,668 27,811 39,080 39,269 37,293 37,489 35,419 35,621 40,944 41,146 39,052 39,262 37,073 37,290 47,197 47,463 45,120 45,391 42,978 43,251 50,055 50,344 47,826 48,120 45,532 45,828
Watts
2,430 2,413 2,699 2,680 2,990 2,970 2,531 2,513 2,811 2,792 3,115 3,094 2,539 2,518 2,827 2,805 3,142 3,118 2,554 2,533 2,844 2,821 3,161 3,136
2,497 2,474 2,785 2,760 3,103 3,076 2,546 2,522 2,840 2,814 3,164 3,136 2,521 2,491 2,815 2,782 3,145 3,108 2,535 2,505 2,830 2,796 3,162 3,125 2,488 2,454 2,773 2,734 3,097 3,054 2,534 2,498 2,823 2,783 3,152 3,108
Source
LWT
24.6
24.6
24.9
24.9
25.3
25.3
25.5
25.5
25.8
25.7
26.0
26.0
33.6
33.6
33.9
33.9
34.3
34.3
34.6
34.6
34.9
34.9
35.2
35.2
42.4
42.4
42.8
42.7
43.2
43.2
43.6
43.6
43.9
43.9
44.3
44.2
59.7
59.6
60.2
60.1
60.6
60.6
61.3
61.2
61.7
61.6
62.1
62.1
72.2
72.2
72.8
72.7
73.4
73.3
74.2
74.1
74.7
74.6
75.2
75.1
CAT 1107 Page 7 of 32
Capacity Data – WRA, WCA 048 – Cooling
EWT GPM WPD EWT GPM LWT WPD
40
50
70
85
90
100
110 12.0
Source
10.0
12.0
10.0
12.0
10.0
12.0
10.0
12.0
10.0
12.0
10.0
12.0
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
12.3
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
50
10.0
12.0
10.0
12.0
10.0
12.0
Load
40.9
42.3
45.2
46.7
49.5
51.1
40.9
42.3
45.2
46.7
49.5
51.1
41.5
42.8
45.9
47.3
50.2
51.7
41.5
42.8
45.9
47.3
50.2
51.7
42.3
43.5
46.7
48.0
51.1
52.4
42.2
43.4
46.6
47.9
51.0
52.4
42.8
43.9
47.3
48.5
51.7
53.0
42.8
43.9
47.2
48.4
51.6
52.9
43.0
44.1
47.5
48.6
51.9
53.1
43.0
44.1
47.4
48.6
51.8
53.1
43.3
44.4
47.8
48.9
52.3
53.5
43.3
44.3
47.8
48.9
52.2
53.4
43.6
44.6
48.1
49.2
52.6
53.7
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
CAT 1107 Page 8 of 32
Capacity
Btu/h
45,207 45,879 48,669 49,424 52,278 53,123 47,211 47,917 50,841 51,635 54,627 55,518 46,309 46,977 49,840 50,591 53,521 54,361 45,936 46,603 49,452 50,202 53,120 53,960 40,847 41,401 43,959 44,582 47,202 47,899 43,228 43,819 46,534 47,199 49,980 50,725 40,543 41,069 43,659 44,249 46,903 47,564 38,569 39,073 41,542 42,109 44,641 45,276 37,507 37,986 40,403 40,941 43,419 44,021 37,737 38,223 40,661 41,207 43,707 44,319 35,176 35,611 37,931 38,420 40,797 41,345 34,157 34,583 36,839 37,319 39,633 40,170 32,172 32,561 34,748 35,187 37,430 37,922
Rejection
Heat of
Btu/h
49,498 50,159 52,909 53,653 56,468 57,302 52,364 53,068 55,987 56,781 59,770 60,661 54,279 54,974 57,955 58,737 61,790 62,665 52,380 53,056 55,942 56,703 59,661 60,513 46,132 46,668 49,144 49,747 52,284 52,959 51,850 52,458 55,249 55,933 58,795 59,562 52,515 53,077 55,847 56,478 59,318 60,025 46,916 47,423 49,905 50,476 53,022 53,660 46,312 46,793 49,222 49,762 52,252 52,857 46,878 47,370 49,836 50,389 52,919 53,538 45,697 46,142 48,512 49,012 51,442 52,002 43,868 44,299 46,581 47,066 49,407 49,951 43,285 43,682 45,909 46,356 48,640 49,140
Watts
1,491 1,496 1,517 1,523 1,546 1,552 1,572 1,577 1,599 1,604 1,627 1,634 1,733 1,738 1,762 1,768 1,792 1,799 1,760 1,766 1,788 1,794 1,818 1,825 2,134 2,139 2,164 2,170 2,195 2,202 2,198 2,203 2,227 2,233 2,258 2,264 2,617 2,622 2,648 2,654 2,681 2,688 2,623 2,628 2,653 2,659 2,684 2,691 2,825 2,831 2,857 2,863 2,891 2,898 2,797 2,802 2,826 2,832 2,858 2,864 3,215 3,220 3,248 3,254 3,282 3,289 3,162 3,167 3,192 3,197 3,223 3,229 3,572 3,576 3,601 3,606 3,632 3,638
Source
LWT
50.4
50.6
51.2
51.3
51.9
52.1
48.7
48.8
49.3
49.5
50.0
50.1
59.9
60.0
60.5
60.7
61.2
61.4
58.2
58.3
58.8
58.9
59.4
59.5
79.4
79.5
80.0
80.1
80.6
80.8
77.8
77.9
78.3
78.4
78.9
79.0
94.1
94.2
94.6
94.7
95.2
95.4
92.6
92.6
93.0
93.1
93.5
93.7
99.0
99.1
99.5
99.6
100.1
100.2
97.5
97.6
98.0
98.0
98.4
98.5
108.8
108.9
109.4
109.5
109.9
110.1
107.4
107.4
107.8
107.9
108.3
108.4
117.3
117.4
117.7
117.8
118.2
118.3
Capacity Data – WRA, WHA 048 – Heating
EWT GPM EWT GPM LWT WPD
30
40
50
70
85
Notes:
1. Heating Data in BOLD = Freeze protection of the source loop is required.
2. Alldataisbasedon100%waterastheheattransferuid.
3. Apply capacity correction factors based on the percent anti-freeze mixture.
4. Do not select units above 120°F leaving water temperature for the load in the heating mode or below 40°F for the load in the cooling mode.
5. Capacity - Btuh produced by the load loop.
6. Load - water loop serving the air handler or terminal device.
7. Source - heat rejection water loop; geothermal or boiler/tower loop.
EWT = Entering water temperature, °F
GPM=Gallonsperminuteow
WPD = Water pressure drop, ft. of water Btu/h = Btu per hour of heat transfer LWT = Leaving water temperature, °F
Source
10.0
12.0
10.0
12.0
10.0
12.0
10.0
12.0
10.0
12.0
100
110
100
110
100
110
100
110
100
110
100
110
100
110
100
110
100
110
100
110
90
10.0
12.0
10.0
12.0
10.0
12.0
90
10.0
12.0
10.0
12.0
10.0
12.0
90
10.0
12.0
10.0
12.0
10.0
12.0
90
10.0
12.0
10.0
12.0
10.0
12.0
90
10.0
12.0
10.0
12.0
10.0
12.0
90
10.0
12.0
10.0
12.0
10.0
12.0
90
10.0
12.0
10.0
12.0
10.0
12.0
90
10.0
12.0
10.0
12.0
10.0
12.0
90
10.0
12.0
10.0
12.0
10.0
12.0
90
10.0
12.0
10.0
12.0
10.0
12.0
Load
96.9
95.8
106.9
105.8
116.8
115.7
97.0
95.8
106.9
105.8
116.9
115.7
97.9
96.6
107.9
106.6
117.8
116.5
98.0
96.7
107.9
106.6
117.9
116.6
99.0
97.5
108.9
107.5
118.9
117.4
99.1
97.6
109.0
107.5
118.9
117.4
101.5
99.6
111.4
109.5
121.2
119.4
101.7
99.7
111.5
109.6
121.3
119.4
103.8
101.5
113.5
111.3
123.3
121.1
104.0
101.7
113.7
111.4
123.5
121.2
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
8.5
12.3
Capacity
Btu/h
35,495 35,505 35,286 35,303 34,996 35,017 41,166 41,179 40,907 40,927 40,555 40,580 40,896 40,916 40,587 40,612 40,231 40,258 41,862 41,885 41,525 41,553 41,143 41,172
45,965 46,002 45,515 45,554 45,054 45,092 47,936 47,977 47,440 47,483 46,934 46,976 59,247 59,344 58,373 58,464 57,553 57,636 58,983 59,086 58,073 58,169 57,218 57,310 68,777 68,947 67,522 67,679 66,364 66,505 70,244 70,428 68,909 69,078 67,675 67,826
Heat of
Absorbtion
26,333 26,420 24,901 25,000 23,281 23,391 25,207 25,291 23,830 23,926 22,274 22,381 31,301 31,412 29,723 29,847 27,980 28,114 31,965 32,080 30,344 30,471 28,556 28,694
Btu/h
37,166 37,310 35,389 35,545 33,466 33,632 37,525 37,673 35,717 35,877 33,765 33,934 47,449 47,674 45,327 45,560 43,104 43,343 49,708 49,949 47,461 47,711 45,113 45,370 57,241 57,559 54,769 55,091 52,222 52,547 60,703 61,049 58,049 58,399 55,321 55,672
Watts
2,855 2,835 3,171 3,149 3,513 3,490 2,974 2,953 3,303 3,280 3,660 3,636 2,983 2,959 3,321 3,295 3,692 3,663 3,000 2,976 3,341 3,315 3,714 3,685
2,934 2,906 3,273 3,243 3,646 3,613 2,991 2,963 3,337 3,306 3,718 3,684 2,962 2,927 3,308 3,268 3,695 3,652 2,978 2,943 3,325 3,286 3,715 3,671 2,924 2,883 3,258 3,213 3,639 3,588 2,977 2,935 3,316 3,270 3,703 3,651
Source
LWT
25.1
25.1
25.4
25.3
25.7
25.6
25.9
25.9
26.1
26.1
26.4
26.3
34.1
34.1
34.4
34.4
34.8
34.7
35.1
35.0
35.3
35.3
35.6
35.6
43.1
43.0
43.4
43.4
43.8
43.7
44.2
44.1
44.4
44.4
44.8
44.7
60.6
60.6
61.0
61.0
61.5
61.4
62.1
62.0
62.4
62.4
62.8
62.8
73.4
73.3
73.9
73.8
74.4
74.3
75.2
75.1
75.6
75.6
76.1
76.0
CAT 1107 Page 9 of 32
Capacity Data – WRA, WCA 060 – Cooling
EWT GPM WPD EWT GPM LWT WPD
40
50
70
85
90
100
110
Source
11.2
13.5
11.2
13.5
11.2
13.5
11.2
13.5
11.2
13.5
11.2
13.5
13.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
14.5
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
55
60
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
50
11.2
13.5
11.2
13.5
11.2
13.5
Load
41.0
42.4
45.3
46.8
49.6
51.2
41.0
42.4
45.3
46.8
49.6
51.2
41.6
43.0
46.0
47.4
50.3
51.9
41.6
42.9
46.0
47.4
50.3
51.8
42.3
43.6
46.8
48.1
51.2
52.6
42.3
43.5
46.7
48.0
51.1
52.5
42.9
44.0
47.3
48.6
51.8
53.1
42.8
44.0
47.3
48.5
51.7
53.0
43.1
44.2
47.5
48.7
52.0
53.3
43.0
44.1
47.5
48.7
51.9
53.2
43.4
44.5
47.9
49.0
52.3
53.6
43.4
44.4
47.8
49.0
52.3
53.5
43.7
44.7
48.2
49.3
52.7
53.8
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
10.5
14.5
CAT 1107 Page 10 of 32
Capacity
Btu/h
50,078 50,822 53,913 54,749 57,910 58,846 52,298 53,080 56,319 57,199 60,513 61,499 51,299 52,038 55,210 56,041 59,288 60,218 50,885 51,624 54,780 55,611 58,843 59,774 45,247 45,862 48,695 49,385 52,288 53,059 47,885 48,540 51,547 52,284 55,365 56,190 44,912 45,494 48,363 49,017 51,957 52,688 42,724 43,283 46,018 46,646 49,451 50,154 41,548 42,078 44,756 45,352 48,097 48,764 41,803 42,341 45,042 45,647 48,416 49,094 38,966 39,448 42,017 42,560 45,193 45,800 37,837 38,309 40,808 41,340 43,903 44,498 35,638 36,070 38,492 38,978 41,463 42,007
Rejection
Heat of
Btu/h
55,480 56,214 59,270 60,096 63,225 64,151 58,684 59,466 62,709 63,591 66,912 67,901 60,908 61,680 64,993 65,861 69,254 70,227 58,767 59,518 62,725 63,570 66,856 67,803 51,915 52,512 55,263 55,933 58,754 59,504 58,336 59,012 62,114 62,874 66,055 66,907 59,265 59,890 62,969 63,671 66,828 67,614 52,932 53,495 56,254 56,888 59,717 60,427 52,321 52,856 55,556 56,157 58,926 59,598 52,945 53,492 56,233 56,847 59,658 60,347 51,750 52,245 54,879 55,435 58,137 58,759 49,661 50,141 52,677 53,216 55,818 56,422 49,132 49,574 52,049 52,545 55,084 55,640
Watts
1,802 1,808 1,834 1,841 1,868 1,876 1,899 1,905 1,932 1,939 1,967 1,975 2,094 2,101 2,129 2,136 2,166 2,174 2,127 2,134 2,161 2,168 2,197 2,206 2,579 2,585 2,615 2,622 2,652 2,661 2,656 2,662 2,691 2,698 2,728 2,736 3,162 3,169 3,200 3,208 3,240 3,248 3,170 3,176 3,206 3,213 3,244 3,251 3,414 3,421 3,453 3,460 3,494 3,502 3,380 3,386 3,416 3,422 3,453 3,461 3,885 3,892 3,925 3,932 3,966 3,974 3,821 3,827 3,857 3,864 3,895 3,902 4,316 4,322 4,352 4,358 4,390 4,396
Source
LWT
50.5
50.6
51.2
51.3
51.9
52.1
48.7
48.8
49.3
49.4
49.9
50.0
59.9
60.0
60.6
60.7
61.2
61.4
58.2
58.3
58.8
58.9
59.3
59.5
79.4
79.5
80.0
80.2
80.7
80.8
77.8
77.9
78.3
78.4
78.9
79.0
94.1
94.2
94.7
94.8
95.3
95.4
92.6
92.7
93.1
93.2
93.6
93.7
99.0
99.1
99.6
99.7
100.2
100.3
97.5
97.6
98.0
98.1
98.5
98.6
108.9
109.0
109.5
109.6
110.0
110.1
107.4
107.5
107.9
108.0
108.3
108.4
117.4
117.4
117.8
117.9
118.2
118.3
Loading...
+ 22 hidden pages