Maytag YMED5720TQ1, MED5707TQ1 Owner’s Manual

ELECTRIC DRYER
USE & CARE GUIDE
p p
SECHEUSE ELECTRIQUE
GUIDE D'UTILISATION ET D'ENTRETIEN
®
FOR QUESTIONS ABOUT FEA1URES, OPERATION/PERFORMANCE, PARTS, ACCESSORIES OR SERVICE
CAI L: 1.800.688.9900
VISIT OUR WEBSITE AF WWW.MAYTAG.COM
IN CANADA, WWW.MAY IAG.CA
PARA OBTENER ACCESO AI MANUAL DE USO Y CUIDADO EN ESPAt_OL, O PARA OBTENER INFORMAC[ON ADIC[ONAL ACERCA DE SU PRODUCTO, VISIIE: WWW.MAYTAG.COM
TENGA I [STO SU NOMERO DE MODEl O COMPLETO. PUEDE ENCONTRAR El NOMERO DE MODELO Y DE SERIE DENTRO DE LA CAVIDAD SUPERIOR DE LA PUEREA.
W10150608A
AU CANADA, POUR ASSISTANCE, INS EALI A[ION OU SERVICE, COMPOSEZ I E : 1.800.807.6777
OU VISITEZ NO1RE SITE INTERNET
WWW.MAY EAG.CA
!ii¸_}_ii!_1!!iiii!!!iiii!!!iiii!!!iiii!!!iiii!!!i!i:!i!i_iii!_!_!ii!}i_i_%i_ii!_l_i_i;i_iiiiii_ii_ii_i_l!!!_!!__i_ i¸i}ii!i_!!!!!!i_!!!!!!i_i_i!!!!ii!ii_i_!i_i!_!_!_!_!!i_i_£(l!_!l:_}}_:_:_i!_!!_i_!!!!i:!i%iiiiii}ii}ii}_1i_i_!!!i:_!_!_!:3}<
TABLE OF CONTENTS
DRYER SAFETY .......................................................................................................................... 3
INSTALLATION INSTRUCTIONS ............................................................................................. 4
Tools and Parts ....................................................................................................................... 4
[ ocation Requirements ......................................................................................................... 4
Electrical Requireme@s - U.S.A. Only ................................................................................... 6
Electrical Requireme@s - Canada Only ................................................................................. 7
Electrical Connection - U.S.A. Only ....................................................................................... 8
Venting Requirements .......................................................................................................... 14
Plan Vent System ................................................................................................................. 16
Install Vent System ............................................................................................................... 17
Install leveling I.egs ............................................................................................................. 17
Connect Ve@ ....................................................................................................................... 18
level Dryer .......................................................................................................................... 18
Reverse Door Swing (Optional) ............................................................................................ 18
Complete Installation ........................................................................................................... 19
DRYER USE ............................................................................................................................. 20
Starting Your Dryer .............................................................................................................. 20
Drying Rack Option ............................................................................................................. 21
DRYER CARE .......................................................................................................................... 21
Cleaning the Dryer Location ................................................................................................ 21
Cleaning the kint Screen ...................................................................................................... 21
Cleaning the Dryer Interior .................................................................................................. 22
Removing Accumulated lint ................................................................................................ 22
Vacation and Moving Care .................................................................................................. 22
Changing the Drum I.ight ..................................................................................................... 22
TROUBLESHOOTING ............................................................................................................ 23
ASSISTANCE OR SERVICE ...................................................................................................... 25
ACCESSORIES ......................................................................................................................... 25
WARRANTY ............................................................................................................................ 26
TABLE DES MATIERES
SECURITE DE [A SECHEUSE ................................................................................................... 27
INSTRUCTIONS D'INSTALLATION ....................................................................................... 28
Outillage et pi_ces ............................................................................................................... 28
Exigences d'emplacement .................................................................................................... 29
Sp(kifications (!lectriques ..................................................................................................... 30
Exigences concernant I'(!vacuation ...................................................................................... 31
Planification du syst6me d'_vacuation ................................................................................. 32
Installation du syst6me d'(!vacuation .................................................................................... 34
Installation des pieds de nivellement ................................................................................... 34
Raccordement du conduit d'(!vacuation .............................................................................. 34
Mise h niveau de la s(!cheuse ............................................................................................... 34
Inversion du sens d'ouverture de la porte (facultatif) ............................................................ 34
Achever I'installation ........................................................................................................... 35
UTI[ISATION DE LA S[_CHEUSE ............................................................................................ :}6
Mise en marche de la s(!cheuse ........................................................................................... 36
Option grille de s(khage ...................................................................................................... %7
ENTRETIEN DE [A SI_CHEUSE ............................................................................................... 38
Nettoyage de I'emplacement de la s_cheuse ....................................................................... 38
Nettoyage du filtre _ charpie ................................................................................................ 38 Z
Nettoyage de I'int6rieur de la s_cheuse ................................................................................ 38
Comment enlever la charpie accumul_e .............................................................................. 38
Pr6cautions _ prendre pour les vacances et avant un d(!m_nagement .................................. 39
Changement de I'ampoule du tambour ................................................................................ 39
Di_PANNAGE .......................................................................................................................... 39
ASSISTANCE OU SERVICE ...................................................................................................... 42
ACCESSOIRES ......................................................................................................................... 42
GARANTIE .............................................................................................................................. 43
i_i_!iii_i_iiIi!iiiiIi!iiiiIi!iiiiIi!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii_)!_}iiiii!!_!_!_!_!_!_!_!_!_!_!_!_i_¸ _ii_ i!i!_iii_1i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i_i!!!_iiiiiiiiiiiiiiiiiiiiiiiiiiii_:_i!i
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING." These words mean:
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
IMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[] Read all instructions before using the dryer. [] Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry- cleaning solvents, or other flammable or explosive
substances as they give off vapors that could ignite or explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
[] Do not reach into the dryer if the drum is moving.
[] Do not install or store the dryer where it will be exposed
to the weather.
[] Do not tamper with controls.
SAVETHESEINSTRUCTIONS
[] Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this
Use and Care Guide or in published user-repair instructions that you understand and have the skills to
carry out.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
[] Clean lint screen before or after each load. [] Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See installation instructions for grounding requirements.
S%
.... 3
Gather the required tools and parts before starting installation. Read and follow the
instructions provided with any tools listed here.
Flat-blade screwdriver
#2 Phillips screwdriver
Adjustable wrench that opens to 1" (2.54 cm) or hex-head socket wrench
(for adjusting dryer feet)
Wire stripper (for U.S. only, direct wire
installations/
Parts supplied Remove parts packages from dryer drum. Check that all parts are included.
Fin snips/new vent installations/
]eve l
Vent clamps
Caulking gun and compound (for installing new exhaust vent)
[_q_e measure
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
4 ',eveling l_'g_
Parts needed
Check local codes. Check existing electrical supply and venting. See "Electrical
Requirements" and "Venting Requirements" before purchasing parts.
Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For further information, please refer to the
"Assistance or Service" section.
If using a power supply cord:
Use a U[. listed power supply cord kit marked for use with clothes dryers. The kit should
contain:
A UI listed 30-amp power supply cord, rated 120/240 volt minimum. ]he cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned ends.
A UI listed strain relief.
You will need
A location that allows for proper exhaust installation. See "Venting Requirements."
A separate 30-amp circuit.
[f you are using a power supply cord, a grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements."
A sturdy floor to support the total weight (dryer and load) of 200 Ibs (90.7 kg). The
combined weight of a companion appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. (If slope is greater
than 1" [2.5 cml, install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not tumble properly and models with automatic sensor cycles may not operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.
4
Installation Clearances
The location must be large enough to allow the dryer door to open fully.
Dryer Dimensions
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the
exhaust vent with elbow. See "Venting Requirements."
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be
considered for the following reasons:
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door and floor moldings.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. [ ouvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
_. 3"*
(7.6cm)
18,,*_1C
(45.7cm)
3,J*
(7.8cm)
1" -_'
(2.5cm)
3-
C
A. Recessed area
B. Side view - closet or confined area (7. Closet door with vents
*Required spacing
Mobile Home - Additional Installation Requirements This dryer is suitable for mobile home installations. The installation must conform to the
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or the
Canadian Manufactured Home Standard, CAN/CSA-Z240 MH. Mobile home installations require:
Metal exhaust system hardware, which is available for purchase from your dealer.
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer
exhaust opening.
It is your responsibility
lb contact a qualified electrical installer.
lb be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and
ordinances. [he National Electric Code requires a 4-wire power supply connection for homes built
after 1996, dryer circuits involved in remodeling after 1996, and all mobile home
installations.
A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.
[.o supply the required or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical
supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in
the neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is recommended that a qualified
electrician determine that the ground path is adequate.
Electrical Connection
[b properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
[his dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire)
within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the
neutral ground conductor must be removed from the external ground connector _green
screw), and secured under the neutral terminal /center or white wire) of the terminal
block. When the neutral ground conductor is secured under the neutral terminal/center
or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.
If local codes do not permit the connection of a neutral ground wire to the neutral wire,
see "Optional 3-wire connection" section in "Electrical Connection - U.S.A. Only" section.
A 4-wire power supply connection must be used when the appliance is installed in a
location where grounding through the neutral conductor is prohibited. Grounding
through the neutral is prohibited for II) new branch-circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding
through the neutral conductors.
If using a power supply cord:
Use a UI. listed power supply cord kit marked for use with clothes dryers. Jhe kit should
contain:
A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned ends.
A U[ listed strain relief.
If your outlet looks like this:
4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade terminals and U[. listed strain
relief. [-he 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. [.he neutral conductor must be identified by a white
cover.
If your outlet looks like this:
3-wire receptacle (lO-30R)
Then choose a 3-wire power supply cord with ring or spade terminals and U[. listed strain
relief. [.he 3-wire power supply cord, at least 4 fl (I .22 m) long, must have three 10-gauge copper wires and match a %wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
Flexible armored cable or nonmetallic sheathed copper cable (with ground wire),
protected with flexible metallic conduit. All current-carrying wires must be insulated.
10-gauge solid copper wire (do not use aluminum).
At least 5 ft (1.52 m) long.
6
GROUNDING iNSTRUCTiONS
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on
the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
[b supply the required 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual branch circuit.
This dryer isequipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length. Be
sure wall receptacle is within reach of dryer's final location.
4-wire r_'ceptack" 14-30R
[] Do not use an extension cord.
If you are using a replacement power supply cord, it is recommended that you use Power
Supply Cord Replacement Part Number 3394208. For further information, please reference the service numbers located in the "Assistance or Service" section.
GROUNDING iNSTRUCTiONS
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes
and ordinances.
Electrical Shock Hazard
Plug into a grounded 4 prong outlet, Failure to do so can result in death or electrical shock.
It is your responsibility
[] [b contact a qualified electrical installer. [] lb be sure that the electrical connection is adequate and in conformance with the
Canadian Electrical Code, C22.1 -latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 £exdale
Blvd., ]bronto, ON Mgw 1R3 CANADA.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Power Supply Cord
Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief.
Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center
terminal (silver). Ground wire (green or bare wire) must be connected to
green ground connector. Connect remaining 2 supply wires to remaining
2 terminals (gold). Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
A B C D
D. Hold-down screw location
A. lbrminal block cover
B. I-xternal ground conductor scr_'w
C. Cc'nter, silver-colored terminal
block screw
E. Neutral ground wire £ Hole below terminal block opening
Fire Hazard
Use 10 gauge solid copper wire. Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections. Failure to do so can result in death, fire, or
electrical shock.
3. Install strain relief Style 1: Power supply cord strain relief
Remove the screws from a %" (1.9 cm) U[. listed strain relief (U[ marking on strain
relief). Put the tabs of the two clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is pointing down, and hold in
place. Tighten strain relief screws just enough to hold the two clamp sections together.
......._..................................................... D
A. .Strain relief tab pointing LIp
B. Hole below terminal block opening C. Clamp section
D. Strain relief tab pointing down
8
Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit
with the dryer cabinet and be in a horizontal position. Do not further tighten strain
relief screws at this point.
Put direct wire cable through tile strain relief. ]he strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw
against the direct wire cable.
II
Style 2: Direct wire strain relief
Unscrew the removable conduit connector and any screws from a %" (1.9 cm) U[. listed strain relief (Ui marking on strain relief). Put the threaded section of the strain
relief through the hole below the terminal block opening. Reaching inside the
terminal [)lock opening, screw the removable conduit connector onto the strain relief threads.
t
A. Removable conduit connector
B. Hole below terminal block opening
(. Strain relief threads
4. Now complete installation following instructions for your type of electrical connection: 4-wire (recommended)
:]-wire (if 4-wire is not available/
Electrical Connection Options
If your home has: And you will be Go to Section ,
4-wire receptacle A UI. listed, 4-wire connection: (NEMA Type 14-30R) 120/240-volt minimum, Power supply cord
(_ 30-amp, dryer power
4-wire direct A fused disconnect or 4-wire connection:
(12.7 crn)
3-wire receptacle (NEMA type 10-30R)
connecting to: :_
supply cord*
circuit breaker box* Direct Wire
A UI. listed,
120/240-volt minimum, 30-amp, dryer power
supply cord*
3-wire connection: Power supply cord
©
3-wire direct A fused disconnect or 3-wire connection:
circuit breaker box* Direct Wire
*If local codes do not permit the connection of a cabinet-ground conductor to the neutral
wire, go to "Optional 3-wire connection" section.
.... 9
4-wire connection: Power Supply Cord
IMPORIANI: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.
B F
C D E G
A. 4-wire receptacle (NEMA type 14-30R)
B.4-prong plug
C. Ground prong
D. Neutral prong
E.Spade terminals with upturned end_
£ _4" ( 1.9 cm) Ut listed strain relief
C. Ring terminals
1.
Remove center silver-colored terminal block screw.
2.
Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver-colored terminal block screw. Tighten screw.
A B C
3. Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.
A
F E
D
A. Exte'rnal ground conductor screw
8. Center silver-colored terminal block screw
C. Neutral wire (white or cente'r wire) D. Y_" (1.9 cm) Ut listed strain relief
E. Ground wire (green or bareJ of power supply cord F. Neutral ground wire
4.
Connect the other wires to outer terminal block screws. [ighten screws.
!! !!
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear paneh Secure cover with hold- down screw.
S
7. You have completed your electrical connections. Now go to "Venting Requirements."
D
A. External ground conductor screw - Dotted line shows position of NEUTRAl
ground wire before being mowtd to center silver-colored terrninal block screw.
B. C_'nter silver-colored t_'rminal block screw C. Neutral wire (white or center wire)
D. ¾" ( t.9 cmJ UL li_ted strain relief
E. Neutral ground wire
10
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of ";-wire connections.
Direct wire cable must have 5 ff (1.52 m) of extra length so dryer can be moved if needed. Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5"
(12.7 cm). Cut 11/2"(3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape
ends of wires into a hook shape.
(12, Z
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as
shown.
Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or
center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.
A B
........C
/
f
A. fxternal ground conductor screw - Dotted line shows position of NEUTRAl
ground wire before being moved to center silver-colored terminal block screw.
B. Ct'nter silver-color_'d terminal block scrt'w C. Neutral wire (white or centt'r wire)
D. _/4" (1.9 cm) UL listed strain relief
E. Neutral ground wire
1. Remove center silver-colored terminal block screw.
3,
Connect ground wire %reen or bare) of power supply cable to external ground conductor screw. Tighten screw.
A
-m
F
E
A. fxternal ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral wire (white or center wire)
D. Y4" (1.9 cm) Ut listed strain relief
E. Ground wire (green ol bare) of powel supply cab& £ Neutral ground wire
4,
Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
3-wire connection: Power Supply Cord
Use where local codes permit connecting cabinet-ground conductor to neutral wire:
A .......
[oosen or remove center silver-colored terminal block screw.
2.
Connect neutral wire (white or center wire) of power supply cord to the center, silver- colored terminal screw of the terminal block. Tighten screw.
i ' /
C G F
A. 3-wire receptacle eNEMA type lO-30R)
B.3-wire plug
C. Neutral prong
D. Spade t_'rminals with up turned enck
E. _" ( 1.9cm) Ut listed strain relief L Ring terminals
G. Neutral (white or center wire)
B C
?
/
!! !I
ram--
5,
Tighten strain relief screws.
6.
Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw,
7,
You have completed your electrical connections. Now go to "Venting Requirements."
12
ioj.......
A
A. Neutral ground wire
B. [xternal ground conductor screw C. C_'nter silver-colored terminal block screw
D. Neutral wire (white or center wire')
E. _" ( 1.9 cm) Ut listed strain relief
3_
Connect the other wires to outer terminal block screws. Tighten screws.
4.
Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot of dryer rear paneh Secure cover with hold-
down screw.
6,
You have completed your electrical connections. Now go to "Venting Requirements."
E
3-wire connection: Direct Wire
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 rn) of extra length so dryer can be moved if needed. Strip 31/2'' (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If
using 3-wire cable with ground wire, cut bare wire even with outer covering. Bend ends of
wires into a hook shape.
Place the hooked end of time neutral wire Iwhite or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end
together. Tighten screw.
B C
<
B <
J. n_
When connecting to the terminal block, place the hooked end of time wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as
shown.
1. I.oosen or remove center silver-colored terminal block screw.
E
A. Neutral ground wire
B. I-xternal ground conductor screw
C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)
E. _" (1.9 cm) UL listed strain reli_.f
Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
!! !!
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
6. You have completed your electrical connections. Now go to "Venting Requirements."
!! iiii_i7!!iii!iiii_ii!!iiiiiiiiiiiiii77iiii_!!;!_7_!7!i;ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_iiI i_,!!i_i!!i_i!!_!i!ii;_:!!i!!!:i!!!13
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do not permit connecting
cabinet-ground conductor to neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver-colored terminal block screw, Tighten screw,
A B C
D
A. Fxternal ground conductor screw
B. Neutral ground wire C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. %" ( 1.9 cm) UL listed strain relief £ Grounding path detenTlined by a qualified electrician
3. Connect the other wires to outer terminal block screws. Tighten screws.
!! !I
4_
Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot of dryer rear paneh Secure cover with hold-
down screw.
6_
Connect a separate copper ground wire from the external ground conductor screw to an
adequate ground.
Fire Hazard
Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death
or fire.
WARNING: Io reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
[he dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building.
14.
If using an existing vent system
Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.
Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance.
Loading...