Electric Dryer
PRODUCT MODEL NUMBERS
MED7500Y
Front view:
3
23
/8"
(594 mm)
331/4"
(845 mm)
Recessed or closet installation (dryer only):
3"
9"
18" min
(229 mm)
(457 mm)
(76 mm)
48 in.
(310 cm2)
Side view: Back view:
1
3
(991 mm)
1
23
/4"
(603 mm)
NOTE: Most installations require a minimum of
5" (127 mm) clearance behind dryer for exhaust
vent with elbow. See “Venting Requirements.”
Custom undercounter installation (dryer only):
2
/4"
(83 mm)
27"
(686 mm)
331/4"
(845 mm)
Power supply
cord/cable
Vent
11
(299 mm)
3
/4"
2
24 in.
3"
(76 mm)
(25 mm)
1"
(25 mm)
Recessed or closet installation – Stacked with stack
kit (Accessory):
(305 mm)
1
/4"
5
(133 mm)
(25 mm)
(1670 mm)
(25 mm)
1"
(76 mm)
1"
12"
(76 mm)
653/4"
(76 mm)
1"
(155 cm2)
3"
3"
3"
48 in.
(310 cm2)
24 in.
(155 cm2)
2
2
1"
1"
(25 mm)
(25 mm)
Installation spacing for recessed area
or closet installation
n All dimensions show recommended and minimum spacing allowed.
n Additional spacing should be considered for ease of
installation and servicing.
n Additional clearances might be required for wall, door, oor moldings, and
dryer venting.
n Additional spacing should be considered on all sides of the dryer to reduce
noise transfer.
n For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are
acceptable.
n Companion appliance spacing should also be considered.
W10445417B
02/2012
ELECTRICAL REQUIREMENTS
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
The Vent System Chart provides venting requirements that will
help achieve best drying performance.
Vent System Chart
Number of
90° elbows
0
Type
of vent
Rigid metal
Box/louvered
hoods
90 ft. (27.4 m)
Angled
hoods
80 ft. (24.4 m)
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
1
2
NOTE: Bottom exhaust installations have a 90º turn inside the
dryer. To determine maximum exhaust length, add one 90º turn
to the chart.
Rigid metal
Rigid metal
80 ft. (24.4 m)
70 ft. (21.3 m)
70 ft. (21.3 m)
60 ft. (18.3 m)
Determine vent length and elbows needed for best
drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied
in Vent System Chart. Exhaust systems longer than those
specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.