Maytag PYG4558AWW Dimension Guide

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
Gas Dryers:
PYG4558AWW
14" max.
• Dimensions (Actual Size) •
Width:
27"
Height including control panel (0" leg adj):
Height NOT including control
panel (0" leg adj):
Depth with door open:
Minimum distance from working surface to
cabinets directly above:
Minimum clearance from back wall:
Minimum distance to door in front:
Minimum clearance right and left:
Door width:
• Additional Information •
• Electrical requirements: 20V, 60Hz, 15 ampere
grounded, fused electrical supply is required. An individual branch (or separate circuit serving only this appliance is recommended). Service cord NOT provided.
• Minimum wire size of 10 gauge, copper wire only.
• Exhaust requirements:
- Dryer may be vented out rear, left side or through
floor (when venting left or down use Kit 33001881).
- Dryer must be exhausted to the outside.
- Use a minimum of 4" diameter rigid aluminum or rigid
galvanized steel duct.
- Keep exhaust as straight and short as possible.
Exhaust systems longer than the chart on page 2 will extend drying time, affect machine performance and collect lint.
- Termination hood should have at least 12" of
clearance between the bottom of the hood and the ground or other obstructions.
- Back pressure must not exceed 0.92" of water column
when measured with a manometer. See page 2 for additional information
Depth:
43 1/4"
35 3/4" 27 1/2" 49 3/4"
17" 14" 0" 2" 0" 22"
Side View
(not to scale)
Right
side
vent
Leg Adj.
0" wall clearance on both sides
Back of unit
(looking out into room)
13 1/2"
0"
17"
36"
at 0"
9"
4 1/2"
3 1/2"
at 0"
Leg Adj
27 1/2"
22"
27"
Rear and Floor Venting
(not to scale)
4 3/4"
Back wall
Closet door
2" min.
Front View
(not to scale)
43 1/4"
at 0"
Leg Adj.
3 1/2" at 0"
Leg Adj.
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter­mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
337
Floor
2 3/8" at 0"
Leg Adj.
Gas Inlet Pipe
BN • A337B149 • • 020611 • 72428 • 25314
13 1/2"
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• Product installation in an alcove area or a closet requires sufficient
make-up air. Each make-up air opening must have a minimum of 36 square inches (more is better). These openings must not be obstructed. A louvered door with equivalent air opening is acceptable.
• Gas requirements: Product comes equipped for use on NATURAL
GAS. If operated on LP gas, use kit 306195. Check with local authorities for permission to convert if required (Canada).
- 1/2" gas supply line recommended, reduced to 3/8" for connection to
gas line on dryer. 1/8" N.P.T. plugged tapping recommended for access of test gauge connection.
- Accessible line shut-off is recommended.
Page 2
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
Gas Dryers:
PYG4558AWW
Maximum duct length chart
48 sq. in.
36 sq. in.
Minimum air openings when installing behind doors (two required).
36 sq. in.
24 sq. in.
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
3"
3"
Number
of 90°
turns
4"
4"
0 45 ft 30 ft 1 35 ft 20 ft 2 25 ft 10 ft
2 1/2"
Maximum length of 4" dia. rigid metal duct
BN • A337B149 • • 020611 • 72428 • 25314