Ultra High Efficiency Air Conditioner20 SEER Residential System2-5 Ton Capacities
2
The iQ Drive® air conditioner system features modulating compressor technology and variable speed indoor and outdoor fan motors. This system is controlled from a two stage cooling and heating thermostat. The system has the capability of adding up to 18% of additional cooling above the rated capacity. The air handler has de-humidification capabilities from the thermostat or duct mounted humidistat.
Features and Benefits
•iQ Drive®: Inverter driven Samsung rotary compressor provides five capacities in modulating operation from a two stage thermostat.
•Interface control board:Two digit LED provides system operation, status and diagnostic troubleshooting information.
- System Control: Utilizes a NORDYNE patented capacity control algorithm to
select the optimum system capacity level.
- System Protection: Internal controls monitor system operation to protect the
inverter drive and compressor.
- Cooling operating temperature range: 50 °F to 125 °F.
- Five Minute Restart Time Delay: When the unit shuts down, a delay keeps the
unit from restarting, eliminating the highest cause for compressor failure.
•Compressor and Component Access: Designed to make servicing easier for the contractor, hinge access panels are provided to all controls and the compressor.
•High Efficiency with the low Sound Levels: 20 SEER with sound ratings of 59-73 depending upon operating conditions.
•Compressor Sound Blanket: Engineered to significantly reduce unwanted compressor noise.
•Variable Speed Condenser Motor and Swept-Wing Fan Blade:A heavy duty brushless DC motor for long lasting reliability and engineered to provide quiet operation. Requires no maintenance and is completely protected from rain and snow.
•Service Port:This port allows the contractor to read the suction pressure in all modes of operation without removing any panels, saving time and increasing serviceability.
•High Pressure Switch: Protects against abnormally high system pressures. Auto-reset feature prevents nuisance service visits.
•Low Pressure Switch: Protects against loss of system refrigerant charge.
•Liquid Line Filter Drier: Included with unit, field installed.
•Micro-Channel Coils: All-Aluminum coils are designed to optimize heat transfer,
and increase durability and reliability.
•Louvered Condenser Guard: Durable metal guard protects the coil from yard hazards and extreme weather.
•Composite Base Pan:Absorbs sound and is corrosion resistant. Composite pan is also stronger and lighter than steel.
•Corrosion Resistance: Designed using galvanized steel with a polyester urethane coat finish. The 950 hour salt spray finish resists corrosion 50% better than comparable units.
•One Piece Top/Orifice: Designed for maximum airflow and quiet operation.
•Removable Top Grille Assembly:Allows ease of service from the top without
disconnecting fan motor leads.
3
IDENTIFICATION CODE
P S A 4 B G 036 K
P = Premier
S = Split
A = Air Conditioner
Design Series
DIMENSIONS
Air Conditioner Outdoor Section
PSA4BG024K036K048K060K
H37 3745 45
W22 1/230 1/230 1/230 1/2
D22 1/230 1/230 1/230 1/2
Product
Identifier
BG = Braze 20 SEER
Electrical Code
K = 208/230-60-1
Normal
Capacity
(000) BTU
Air Discharge
Allow Adequate Clearance for Airflow
W
D
H
4
PHYSICAL AND ALECTRICAL SPECIFICATIONS / OUTDOOR UNITS
PSA4BG Series Residential Split System Air Conditioner 20 SEER
Model Number PSA4BG-024K036K048K060K
ELECTRICAL
DATA
Volts-Cycles-Phase Total Amps11.917.318.928.8Delay Fuse Max.
(1)
(2)
20353560
Min. Circuit Ampacity14.2212335.1
Field Control Wiring Connections(24 vac from thermostat/indoor side)
Installation Refrigerant Vapor Line Size (All liquid lines 3/8” OD)
25 - 39 ft. equiv. 3/4”7/8”1-1/8”1-1/8”40 - 75 ft. equiv. 75 - 100 ft. equiv.
(4)
(4)
7/8”1-1/8”1-1/8”1-1/8”
1-1/8”1-1/8”1-1/8”1-1/8”
Refrigerant TypeR410A
Refrigerant Charge (oz.), 15 ft. line set (factory charge)78
Weight, lbs. (approximate)
(1) Operating Voltage Range: 187 vac min. to 253 vac max.(2) HACR Type circuit breakers may be used.
(3)
Additional charge for longer line sets as follows (with 3/8” liquid lines):
3/4” vapor line: 0.6 oz per additional foot7/8” vapor line: 0.7 oz per additional foot1-1/8” vapor line: 0.8 oz per additional foot
Minimum outdoor temperature for cooling is 50°F.(4) Refrigerant Tubing Limitations-The compressor manufacturer imposes a maximum equivalent line set length of 100 ft. Furthermore, vertical elevation shall not exceed 50 ft.
As shipped149197225240Net136178205220
(3)
93
(3)
110
(3)
123
(3)
See current AHRI Directory for certified combinations and ratings.
Note: Conditions for Nominal Capacity rating are 80°F dry bulb temperature, 67°F wet bulb temperature (approximately 51% RH) indoors, 95°F out-door ambient temperature. Minimum outdoor temperature for cooling is 50°F.
See current AHRI Directory for certified combinations and ratings.
www.ahridirectory.org