www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
Free Standing Gas Ranges:
PGR4310CDW and PGR4310CDQ
• Dimensions (Actual Size) •
Height of cooking surface: 35 7/8"
Height overall:
Case width:
Depth NOT including handle:
Door swing:
Height at 0" leg adjustment:
• Additional Information •
• Units depth including door handle is 28 1/8".
• Can be installed with the back against (0") a vertical
combustible wall, and the sides below the cooktop
surface against (0") combustible base cabinets.
• Electrical requirements: 120 VAC,60Hz. 15 amp
grounded circuit protection is required.
• Gas requirements: Gas supply line should be 3/4".
Install a manual shutoff valve in an accessible location
in the gas line external to this appliance for the purpose
of turning on or shutting off gas to the appliance. The
appliance is shipped from the factory equipped for use
with natural gas and can be converted to LP gas in the
field . The maximum gas supply pressure for both LP
and natural gas is 14" WC. Minimum Pressure for
Natural gas is 5" WC. Minimum Pressure for LP gas is
11" WC.
• Proper operation requires use of range hood.
• Cabinetry over cooktop : 30" minimum clearance
between the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet. 24" minimum
when bottom of wood or metal cabinet is protected by
not less than 1/4" flame retardant millboard covered
with not less than no. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or copper.
See page 2 for additional information
45 1/4"
29 7/8"
26 1/8"
20 1/2"
36"Height at full leg adjustment:
35 1/2"
29 7/8"
45 1/4"
35 7/8"
26 1/8"
Locate gas line
within shadded
area
11"
Wall View
(not to scale)
Wall View
(not to scale)
1"
28"
Electric
Location
Gas Location
30"
(not to scale)
20 1/2"
Door open
Locate electrical
supply outlet (flush
with wall) within
hashed area. Area is
13" W X 9" H.
located 9 3/8" above
floor and 1 1/2" from
right wall.
2 1/4"
Upper cabinets
can only be 13"
deep maximum.
Over range
cabinet is NOT
recommended.
30" Min.
18"
Side clearance
from cooktop to
18" above the
cooktop is 3" on
each side (see
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
255
Countertop
height
36"
Range
solid arera)
30" Minimum
cutout width
BN • A255B149 • • 032603 • 95658 • 85742
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• To eliminate the hazard of reaching over heated surface units,
cabinet storage space located above the surface units should be
avoided. If cabinet storage is to be provided, the hazard can be
reduced by installing a range hood that projects horizontally a
minimum of 5" beyond the bottom of the cabinets.
• For Free-standing installations the cutout opening width is 30" ± 1/16"
minimum. The height of the countertop is 36" and countertop depth is
25".
Page 2
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
Free Standing Gas Ranges:
PGR4310CDW and PGR4310CDQ
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
BN • A255B149 • • 032603 • 95658 • 85742
149