Maytag MMV1153BAS, MMV1153BAW, MMV1153BAB Installation Guide

Installation Instructions
Over the Range Microwave Oven
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT -- Save these instructions for
local inspector's use.
IMPORTANT -- Observe all governing codes
and ordinances.
Note to Consumer- Keep these instructions for future reference.
Skill level - Installation of this appliance requires
basic mechanical and electrical skills.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under the Warranty.
READ CAREFULLY. KEEP THESE INSTRUCTIONS.
CONTENTS
Installation Instructions
General information
Important Safety Instructions ..................... 3
Electrical Requirements .............................. 3
Hood Exhaust ........................................... 4, 5
Damage - Shipment/Installation ................. 6
Parts Included ............................................... 6
Tools You Will Need ..................................... 7
Mounting Space ............................................ 7
Step-by-step installation guide
Placement of Mounting Plate ................ 8-10
Removing the Mounting Plate ................... 8
Finding the Wall Studs .............................. 8
Determining Wall Plate Location ............... 9
Aligning the Wall Plate ............................ 10
C Outside Back Exhaust ............................. 18-21
Preparing Rear Wall ................................ 18
Attach Mounting Plate to Wall ........... 18, 19
Preparation of Top Cabinet ..................... 19
Adjust Blower .................................... 19, 20
Mount the Microwave Oven ............... 20, 21
Before You Use Your Microwave .............. 22
Installation Types ................................. 11-21
A Recircutating ........................................... 12-13
Attach Mounting Plate to Wall ................. 12
Preparation of Top Cabinet ..................... 12
Mount the Microwave Oven ..................... 13
B Outside Top Exhaust .............................. 14-17
Attach Mounting Plate to Wall ................. 14
Preparation of Top Cabinet ..................... 15
Adjust Blower .................................... 15, 16
Check Damper Operation ........................ 16
Mount Microwave Oven ........................... 16
Adjust Exhaust Adaptor ........................... 17
Connecting Ductwork .............................. 17
Installation Instructions
IMPORTANT SAFETY INSTRUCTIONS
This product requires a three-prong grounded outlet. The installer must perform a ground continuity check on the power outlet box before beginning the installation to insure that the outlet box is properly grounded. If not properly grounded, or if the outlet box does not meet electrical requirements noted (under ELECTRICAL REQUIREMENTS), a qualified electrician should be employed to correct any
deficiencies.
CAUTION: For personal safety, remove house fuse or open circuit breaker before
beginning installation to avoid severe or fatal shock
injury.
CAUTION: For personal safety, the mounting surface must be capable of supporting the cabinet load, in addition to the added weight of this 59 pound product, plus additional oven loads of up to 50 pounds or a total weight of 109 pounds.
CAUTION: For personal safety, this product cannot be installed in cabinet arrangements such as an island ora peninsula. It must be mounted to
BOTH a top cabinet AND a wall.
NOTE: For easier installation and personal safety, it is recommended that two people install this product.
You should have the wall receptacle and circuit
checked by a qualified electrician to make sure
the receptacle is properly grounded.
Where a standard two-prong wall receptacle is encountered, it is very important to have it
replaced with a properly grounded three-prong
wall receptacle, installed by a qualified electrician.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT, DEFORM OR REMOVE ANY OF THE PRONGS
FROM THE POWER CORD. DO NOT USE WITH
AN EXTENSION CORD.
ELECTRICAL REQUIREMENTS
Product rating is 120 volts AC, 60 Hertz, 14.5 amps (13 amps, CANADA) and 1.65 kilowatts (1.5 kilowatts, CANADA). This product must be connected to a supply circuit of the proper voltage and frequency. Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for this kilowatt rating. The power supply cord and plug should be brought to a
separate 20 ampere branch circuit single grounded outlet. The outlet box should be located in the cabinet
above the microwave oven. The outlet box and
supply circuit should be installed by a qualified electrician and conform to the National Electrical
Code or the prevailing local code.
IMPORTANT-PLEASE READ CAREFULLY. FOR
PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED TO AVOID SEVERE OR
FATAL SHOCK.
The power cord of this appliance is equipped with a three-prong (grounding) plug which
mates with a standard three-prong (grounding)
wall receptacle to
Insure proper ground exists
before use
minimize the possibility of electric shock hazard
from this appliance.
3
Installation Instructions
HOOD EXHAUST
NOTE: Read these next two pages only if you plan to vent your exhaust to the outside. If you plan to recirculate the air back into the room, proceed to page 11.
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible ductwork installation.
DUCT PIECES
Roof Cap
12 Ft. Straight Duct (6"
[]
Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood.
* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have
to be cut to fit, using the tin snips, in order to allow free movement of the damper.
Round)
Rectangular-to-Round 5 Ft.
Transition Adaptor*
EQUIVALENT NUMBER LENGTH x USED
24 Ft. x (1)
12 Ft. x (1)
x (1)
Total Length
EQUIVALENT
= LENGTH
= 24 Ft.
= 12 Ft.
= 5 Ft.
= 41 Ft.
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible ductwork installation.
DUCT PIECES EQUIVALENT NUMBER EQUIVALENT
LENGTH* x USED = LENGTH
Roof Cap 40 Ft. x (1) = 40 Ft.
- 3 Ft. Straight Duct (3¼"x10" 3Ft. x (1) = 3Ft.
Rectangular)
(_ 90 ° Elbow 10 Ft. x (2) = 20 Ft.
Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood. Total Length = 63 Ft.
NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate
exhaust.
4
Installation Instructions
NOTE: If you need to install ducts, note that the total
duct length of 3¼" x 10" rectangular or 6" diameter round duct should not exceed 60 equivalent feet.
Outside ventilation requires a HOOD EXHAUST
DUCT. Read the following carefully. NOTE: It is important that venting be installed using
the most direct route and with as few elbows as possible. This ensures clear venting of exhaust and
helps prevent blockages. Also, make sure dampers swing freely and nothing is blocking the ducts.
Exhaust connection:
The hood exhaust has been designed to mate with a standard 3¼"x 10" rectangular duct.
If a round duct is required, a rectangular-to-round
transition adaptor must be used. Do not use less than a 6" diameter duct.
DUCT PIECES EQUIVALENT NUMBER EQUIVALENT
LENGTH x USED = LENGTH
Transition Adaptor* 5 Ft. x ( = Ft.
Rectangular-to-Round
Maximum duct length:
For satisfactory air movement, the total duct length of 3¼" x 10" rectangular or 6" diameter round duct
should not exceed 60 equivalent feet.
Elbows, transitions, wall and roof caps, etc., present additional resistance to
airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When
calculating the total duct length, add the equivalent
lengths of all transitions and adaptors plus the length of all straight duct sections. The chart below shows you how to calculate total equivalent ductwork length
using the approximate feet of equivalent length of some typical ducts.
Wall Cap 40 Ft. x ( = Ft.
(_ 90 ° Elbow 10 Ft. x ( = Ft.
(_ 45 ° Elbow 5 Ft. x ( = Ft.
90 ° Elbow 25 Ft. x ( = Ft.
45 ° Elbow 5 Ft. x ( = Ft.
Roof Cap 24 Ft. x ( = Ft.
-1 Straight Duct 6" Round or
3¼" x 10" Rectangular 1 Ft. x ( = Ft.
* IMPORTANT: If a rectangular-to-
round transition adaptor is used, the
bottom corners of the damper will have to be cut to fit, using the tin
Total Ductwork = Ft.
snips, in order to allow free movement of the damper.
Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting
performance with any vent hood.
5
Installation Instructions
DAMAGE - SHIPMENT/ INSTALLATION
If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.
If the unit is damaged by the customer, repair or replacement is the responsibility of the
customer.
If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between customer and
installer.
PARTS INCLUDED
HARDWARE PACKET
PART QUANTITY
Wood Screws 1 (¼" x 2")
Toggle Bolts 2
@_ (and wing nuts)
(3/1_"x 3") Self-aligning 2
_/ Machine Screws
(¼"-28 x 3¼") Nylon Grommet 2
(for metal cabinets)
You will find the installation hardware contained in a
packet with the unit. Check to make sure you have all
these parts.
NOTE: Some extra parts are included.
ADDITIONAL PARTS
PART
TOP CABINET TEMPLATE
REAR WALL TEMPLATE
Top Cabinet Template
Rear Wall Template
Installation Instructions
Separately Packed
Grease Filter
Exhaust adaptor
QUANTITY
1
6
Installation Instructions
TOOLS YOU WILL NEED
..... _j _and straight edge
# ! and #2 Phillips screwdriver Pencil
Ruler or tape measure
(optional)
Tin snips (for cutting damper, if required)
Gloves
Safety goggles
Scissors (to cut template, if necessary)
Saw (saber, hole or keyhole)
MOUNTING SPACE
Level
Backsplash
Electric drill with 3/16", _/2" and 5/8" drill bits
Stud finder or Hammer (optional)
NOTES:
Bottom edge of
cabinet needs to be 33" or more from the
cooking surface
The space between the cabinets must be 30" wide and free of obstructions.
This microwave oven is for installation over ranges up to 33" wide.
If you are going to vent your microwave oven to the outside, see Hood Exhaust
Section for exhaust duct preparation.
When installing the microwave oven beneath smooth flat cabinets be careful
to follow the instructions on the top cabinet template for power cord
clearance.
Filler blocks or scrap wood pieces, if needed for top
cabinet spacing (used on recessed bottom cabinet
installations only)
Duct and masking tape
7
Installation Instructions
1.PLACEMENT OF THE MOUNTING PLATE
A. REMOVING THE MICROWAVE
OVEN FROM THE CARTON/
REMOVING THE MOUNTING PLATE
1, Remove the installation instructions, Exhaust
adaptor, filters, glass tray and the small hardware bag. Do not remove the Styrofoam protecting the
front of the oven.
2. Fold back all 4 carton flaps fully against carton sides. Then carefully roll the oven and carton over
onto the top side. The oven should be resting in the Styrofoam.
B. FINDING THE WALL STUDS
1. Find the studs, using one of the following
methods: A. Stud finder-a magnetic device which locates
nails.
OR
3. Pull the carton up and off the oven.
4. Remove and properly discard plastic bags.
Screws
Mounting Plate _
5, Remove the 2 screws from the mounting plate.
This plate will be used as the rear wall template and for mounting.
NOTE: You will have to reuse two screws in original
location of outcase after removing mounting plate.
Screws
T
B. Use a hammer to tap lightly across the
mounting surface to find a solid sound. This
will indicate a stud location.
2, After locating the stud(s), find the center by
probing the wall with a small nail to find the edges of the stud. Then place a mark halfway between the edges. The center of any adjacent studs
should be 16" or 24" from this mark.
3, Draw a line down the center of the studs.
THE MICROWAVE MUST BE CONNECTED TO AT
LEAST ONE WALL STUD.
8
Loading...