INSTALLATIONINSTRUCTIONS
COMMERCIALSTACKEDDRYER
Electric (120/240-Volt,60-Hz)
®
INSTRUCTIONSPOUR L'INSTALLATIONffUNE
p #
SECHEUSECOMMERCIALESUPERPOSEE
#
Electrique (120/240-Volt,60 Hz)
Table of Contents/Table des mati_res ........................................ 2
J
Actual unit may or may not
contain doors with windows,
depending on model
Seton te modete, te pr6sent
appareit n'offre peut-_tre pas
de hubtot de porte.
W10184531A www.maytag.com
TABLEOF CONTENTS TABLEDESMATIERES
DRYER SAFETY ............................................................................ 2
INSTALLATION REQUIREMENTS .............................................. 3
Tools and Parts .......................................................................... 3
Location Requirements .............................................................. 4
Electrical Requirements ............................................................ 5
Venting Requirements .............................................................. 5
INSTALLATION INSTRUCTIONS ............................................ 7
Make Electrical Connection ........................................................ 7
Connect Vent .............................................................................. 7
Complete Installation ................................................................ 8
ELECTRONIC CONTROL SETUP ............................................. 8
MAINTENANCE INSTRUCTIONS ............................................ 8
WARRANTY ................................................................................ 9
SECURITE DE LA SECHEUSE .............................................. 10
EXIGENCES D'INSTALLATION ................................................ 11
Outitlage et pi_ces .................................................................... 11
Exigences d'emptacement ...................................................... 12
Specifications 61ectriques ........................................................... 13
Exigences concemant l'evacuation .......................................... 14
INSTRUCTIONS DqNSTALLATION - S#CHEUSE
ELECTRIQUE ............................................................................ 16
Raccordement electrique ........................................................ 16
Raccordement du conduit d'evacuation ................................ 16
Achever I'instattation ................................................................ 17
REGLAGE DE LA COMMANDE ELECTRONIQUE .............. 17
INSTRUCTIONS D'ENTRETIEN ............................................ 17
GARANTIE ................................................................................ 18
DRYERSAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately_
fo|low instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING - "Risk of Fire"
- Clothes dryer installation must be performed by a qualified installer,
- install the clothes dryer according to the manufacturer's instructions and local codes.
- Do not install a clothes dryer with flexible plastic venting materials, if flexible metal
(foil type) duct is installed, it must be of a specific type identified by the appliance
manufacturer as suitable for use with clothes dryers. Flexible venting materials are
known to collapse, be easily crushed, and trap lint. These conditions will obstruct
clothes dryer airflow and increase the risk of fire.
- To reduce the risk of severe injury or death, follow all installation instructions,
- Save these instructions.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[] Read all instructions before using the dryer. [] Do not repair or replace any part of the dryer or attempt
[] Do not place items exposed to cooking oils in your dryer, any servicing unless specifically recommended in this
Items contaminated with cooking oils may contribute to Use and Care Guide or in published user=repair instruc=
a chemical reaction that could cause a load to catch fire. tions that you understand and have the skills to carry out.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry=
cleaning solvents, other flammable, or explosive
substances as they give off vapors that could ignite or
explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
[] Do not reach into the dryer if the drum is moving.
[] Do not install or store the dryer where it will be exposed
to the weather.
[] Do not tamper with controls.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber=like materials.
[] Clean lint screen before or after each load.
[] Keep area around the exhaust opening and adjacent sur=
rounding areas free from the accumulation of lint,dust,
and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See installation instructions for grounding requirements.
SAVE THESE iNSTRUCTiONS
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
[] 8" or 10" pipe wrench [] 5/16" open-end wrench
[] 8" or 10" adjustable wrench [] Utility knife
[] Flat-blade screwdriver [] Vent clamps
[] Phillips screwdriver [] Pipe-joint compound
[] Adjustable wrench that resistant to LP gas
opens to 1" (2.5 cm) or 1" [] Caulk gun and caulk (for
(25 mm) hex-head socket installing new exhaust vent)
wrench [] Pliers
[] Security T-20 TORX_)tdriver [] Putty knife
[] Level
Parts supplied
Remove parts bag from dryer drum. Check that all parts were
included.
[] 10-32 x 5/16" serrated screw (4)
[] Cotter pin (2)
1 ® TORX is a registered trademark of Acument Intellectual Properties, LLC.
3
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: Observe all governing codes and ordinances.
NOTE:
[] The dryer must not be installed in an area where it will be
exposed to water and/or weather.
[] This dryer must not be installed in a closet with a door.
Recessed Area Installation instructions
This dryer may be installed in a recessed area. Minimum
installation clearances can be found on the rear of the dryer.
The dryer must be exhausted outdoors.
Product Dimensions
top dryer
exhaust
5-3/8"
(13.7 cm)
+
+
37"
(94.0cm)
5-3/8"
I (13.icm)
\
13-1/2"
(34.3 cm)
41"
(104.1 cm)
3-1/8"
(7.9 cm)
Back View
bottom
dryer
exhaust
Minimum Installation Clearances
IRecessedl 2in I 0in I 12in I -- I
__1 )_-2" (5cm)j
Back Sides Top Front
(5cm) (0cm) (30cm)
+
12"
(30 cm)
O
O
0" (0cm)_ _ -_1|_ - 0" (0cm)
Recessed Recessed
side view front view
Additional clearances for wall, door, and floor moldings may be required
or if external exhaust elbow is used.
i_,
O"
(Ocm)
5-1/2" (14.0 cm)
+
door_
23-3/4"
(60.3 cm)
27" (68.6 cm)
10-1/2"
(26.7cm)
--.-_ :
7_1/2,,---_4
(19.1cm)
=L
29-1/4" _
(74.3cm)
T
76-3/4"
(195cm)
@--
-Q--
approx. 1"
(2,5cm)
Side View
IMPORTANT:Thedryermustbeelectricallygroundedin
accordancewithlocalcodesandordinancesor,intheabsence
oflocalcodes,withCSAStandardsC22.1-94,Canadian
ElectricalCode,Part1andC22.2No.O-M91,latestedition.
Ifcodespermitandaseparategroundwireisused,itis
recommendedthataqualifiedelectricalinstallerdeterminethat
thegroundpathisadequate.
Acopyoftheabovecodestandardscanbeobtainedfrom:
CanadianStandardsAssociation,
178RexdaleBlvd.,Toronto,ONM9W1R3CANADA
[] Afour-wire,single-phase,120/240volt,60Hz,AConly
electricalsupply(orfour-wire,120/208volt,ifspecifiedonthe
model/serialratingplate)isrequiredonaseparate,60-amp
circuit,fusedonbothsidesoftheline.Atime-delayfuseor
circuitbreakerisrecommended.
Recommended Ground Method
It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformity with CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. O-M91, latest edition.
GROUNDING INSTRUCTIONS
[] For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment=grounding
conductor must be run with the circuit conductors and
connected to the equipment=grounding terminal or lead on
the dryer.
WARNING: Improper connection of the equipment=
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded.
SAVE THESE INSTRUCTIONS
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
[] The dryer vent must not be exhausted into any gas vent,
chimney, wail, ceiling, attic, crawtspace, or a concealed space
of a building.
[] Use only rigid or flexible metal duct shall be used for
exhausting.
[] Do not use an exhaust hood with a magnetic latch.
[] Do not install flexible metal vent in enclosed walls, ceilings,
or floors.
[] 4" (102 mm) heavy metal vent and clamps must be used. Do
not use plastic or metal foil vent.
[] Use clamps to seat all joints. The duct shall not be assembled
with screws or other fastening means that extend into the
duct and catch lint. Do not use duct tape.
[] The total length of flexible metal vent shall not exceed 8 ft
(2.4 m).
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
IMPORTANT: Observe all governing codes and ordinances.
Rigid metal vent is recommended to prevent crushing and
kinking.
Flexible metal vent must be fully extended and supported when
the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow
and poor performance.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home or business.
Exhaust hood must be at least 12" (30.5 cm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks, or bushes).
If using an existing vent system, clean lint from the entire length
of the system and make sure exhaust hood is not plugged with
lint. Replace any plastic or metal foil vent with rigid metal vent.
5
Plan installation to use the fewest number of elbows and turns.
A
ExhaustAir Flow
A.Good
B.Better
Allow as much room as possible when using elbows or making
turns. Bend vent gradually to avoid kinking.
Vent outlet is located at the center of the bottom dryer back.
The vent can be routed up, down, left, right, behind the dryer,
or straight out the back of the dryer.
Vent System Length
Maximum length of vent system depends upon the type of vent
used, number of elbows, and type of exhaust hood. The
maximum length for rigid vent is shown in the chart.
Maximum Vent Length
4" (10.2 cm) Diameter Exhaust Hoods
[] A main vent can be used for venting a group of dryers. The
main vent should be sized to remove 200 CFM of air per
dryer. Large-capacity lint screens of proper design may be
used in the main vent if checked and cleaned frequently. The
room where the dryers are located should have make-up air
equal to or greater than the CFM of all the dryers in the room.
[] Back-draft Damper Kits, Part No. 3391910, are available from
your dealer and should be installed in the vent of each dryer
to prevent exhausted air from returning into the dryers and to
keep the exhaust in balance within the main vent.
Unobstructed air openings are required.
Each vent should enter the main vent at an angle pointing in the
direction of the airflow. Vents entering from the opposite side
should be staggered to reduce the exhausted air from interfering
with the other vents.
The maximum angle of each vent entering the main vent should
be no more than 30°.
air flow _ B _---
Rigid Metal Vent
No. of 90 ° turns Box Hood and Louvered Style Angled Hood Style
0 130 ft. (39.6 m) 129 ft. (39.3 m)
1 125 ft. (38.1 m) 119 ft. (36.3 m)
2 115 ft. (35.1 m) 109 ft. (33.2 m)
3 106 ft. (32.3 m) 100 ft. (30.5 m)
4 98 ft. (29.9 m) 92 ft. (28.0 m)
For vent systems not covered by the vent specification chart,
see your parts distributor.
If dryer is installed in a confined area, such as a bedroom
or bathroom, provision must be made for enough air
for combustion and ventilation. (Check governing codes and
ordinances.) See "Recessed Area Installation Instructions" in the
"Location Requirements" section.
A 4" (10.2 cm) outlet hood is preferred. However, a 21Z_"(6.4 cm)
outlet exhaust hood may be used. A 21Z_'' (6.4 cm) outlet creates
greater back pressure than other hood types. For permanent
installation, a stationary vent system is required.
A.Individualdryervent
B.Mainvent
Keep air openings free of dry cleaning fluid fumes. Fumes create
acids which, when drawn through the dryer heating units, can
damage dryers and loads being dried.
A clean-out cover should be located on the main vent for periodic
cleaning of the vent system.
If an exhaust hood cannot be used:
B
U ,,y C
M_b12e (a3OyCm_c tmea;a_ice
A.Exhau I II
2 ft. (61 cm) min.
above highest
point of building
G.Roof
The outside end of the main vent should have a sweep elbow
directed downward. If the main vent travels vertically through the
roof, rather than through the watt, install a 180° sweep elbow on
the end of the vent at least 2 feet (61 cm) above the highest part
of the building. The opening in the wall or roof shall have a
diameter 1/2" (1.3 cm) larger than the vent diameter. The vent
should be centered in the opening.
Do not install screening or cap over the end of the vent.