INSTALLATIONINSTRUCTIONS
COMMERCIALSTACKEDDRYER
Gas (120-Volt,60-Hz)or Electric (120/240-Volt,60-Hz)
INSTRUCTIONSPOUR L'INSTALLATIONffUNE
# #
SECHEUSECOMMERCIALESUPERPOSEE
h gaz (120Volts, 60 Hz) ou (_lectrique (120/240Volts, 60 Hz)
Table of Contents/Table des mati_res ........................................ 2
J
Actual unit may or may not
contain doors with windows,
depending on model
Seton te modete, te pr6sent
appareit n'offre peut-_tre pas
de hubtot de porte.
W10135153B www.maytag.com
W10135158A - SP
TABLEOF CONTENTS
TABLEDESMATIERES
DRYER SAFETY ............................................................................ 2
INSTALLATION REQUIREMENTS .............................................. 4
Tools and Parts .......................................................................... 4
Location Requirements .............................................................. 4
Electrical Requirements - Gas Dryer ........................................ 6
Electrical Requirements - Electric Dryer (U.S. only) ................ 6
Gas Supply Requirements ........................................................ 7
Venting Requirements .............................................................. 8
INSTALLATION INSTRUCTIONS - GAS DRYER .................. 10
Make Gas Connection .............................................................. 10
Connect Vent ............................................................................ 10
Complete Installation .............................................................. 10
INSTALLATION iNSTRUCTIONS- ELECTRIC DRYER ........ 11
Make Electrical Connection ...................................................... 11
Connect Vent ............................................................................ 15
Complete Installation .............................................................. 15
ELECTRONIC CONTROL SETUP ........................................... 15
MAINTENANCE INSTRUCTIONS .......................................... 15
DRYERSAFETY
SECURITE DE LA SECHEUSE .............................................. 17
EXIGENCES D'INSTALLATION ................................................ 19
Outitlage et pi_ces .................................................................... 19
E×igences d'emplacement ...................................................... 19
Specifications 6tectriques - s6cheuse h gaz ........................... 21
Specifications electriques - s_cheuse etectrique
(E.-U. seulement) ..................................................................... 21
Specifications de I'atimentation en gaz .................................. 22
E×igences concemant I'evacuation .......................................... 23
iNSTRUCTIONS D'INSTALLATION - S_=CHEUSE A GAZ ....25
Raccordement h ta canatisation de gaz ...................................... 25
Raccordement du conduit d'evacuation ................................ 25
Achever I'instattation ................................................................ 26
iNSTRUCTIONS D'INSTALLATION - S_eCHEUSE
ELECTRIQUE ............................................................................ 26
Raccordement electrique ........................................................ 26
Raccordement du conduit d'evacuation ................................ 31
Achever I'instattation ................................................................ 31
REGLAGE DE LA COMMANDE ELECTRONIQUE .............. 31
iNSTRUCTIONS D'ENTRETIEN .............................................. 31
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately_
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
m It is recommended that the owner post, in a prominent location, instructions for the customer's use in the event the customer smells
gas. This information should be obtained from your gas supplier.
m Post the following warning in a prominent location.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- WHAT TO DO iF YOU SMELL GAS:
®Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
= Clear the room, building, or area of all occupants.
= Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• if you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the "What to do if you smell gas" instructions.
In the State of Massachusetts, the following installation instructions apply:
[] Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] If using a ball valve, it shall be a T-handle type.
[] A flexible gas connector, when used, must not exceed 3 feet.
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[] Read all instructions before using the dryer. [] Do not repair or replace any part of the dryer or attempt
[] Do not place items exposed to cooking oils in your dryer, any servicing unless specifically recommended in this
Items contaminated with cooking oils may contribute to Use and Care Guide or in published user-repair instruc=
a chemical reaction that could cause a load to catch fire. tions that you understand and have the skills to carry out.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry-
cleaning solvents, other flammable, or explosive
substances as they give off vapors that could ignite or
explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
[] Do not reach into the dryer if the drum is moving.
[] Do not install or store the dryer where it will be exposed
to the weather.
[] Do not tamper with controls.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber=like materials.
[] Clean lint screen before or after each load.
[] Keep area around the exhaust opening and adjacent sur-
rounding areas free from the accumulation of lint,dust,
and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See installation instructions for grounding requirements.
SAVE THESE INSTRUCTIONS
3
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSl/NFPA 70 or Canadian Electrical Code, CSA C22.1.
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
m 8" or 10" pipe wrench
m 8" or 10" adjustable wrench
m Flat-blade screwdriver
m Phillips screwdriver
m Adjustable wrench that opens to 1" (2.5 cm) or 1" (25 mm)
hex-head socket wrench
m Security T-20 TORXTM driver
m Level
m 5/16" open-end wrench
m Vent clamps
m Pipe-joint compound resistant to LP gas
m Caulk gun and caulk (for installing new exhaust vent)
m Pliers
m Putty knife
Parts supplied
Remove parts bag from dryer drum. Check that all parts were
included.
[] 10-32 x 5/16" serrated screw (4)
[] Security cotter pin (2)
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion, or fire.
If installing a gas dryer:
IMPORTANT: Observe all governing codes and ordinances.
[] Check code requirements: Some codes limit or do not permit
installation of clothes dryers in closets or sleeping quarters.
Contact your local building inspector.
[] Make sure that lower edges of the cabinet, plus the back and
bottom sides of the dryer, are free of obstructions to permit
adequate clearance of air openings for combustion air. See
"Recessed Area Installation Instructions" below for minimum
spacing requirements.
NOTE:
[] The dryer must not be installed in an area where it will be
exposed to water and/or weather.
[] This dryer must not be installed in a closet with a door.
Explosion Hazard
1@ TORX is a registered trademark of Textron Innovations, Inc.
Recessed Area InstaNlation Instructions
This dryer may be installed in a recessed area. Minimum
installation clearances can be found on the rear of the dryer.
The dryer must be exhausted outdoors.
Minimum Installation Clearances
Back Sides Top Front
IRecessedl 2in I 0in I 12in I -- I
(5 cm) (0 cm) (30 cm)
Product Dimensions
_-2" (5 cm)// T
12"
(30 cm)
O
_] 0"
r---I::: r-1
(0 cm)
O
,L
0" (0 cm)_ _ --_1/_ -- 0" (0 cm)
Recessed Recessed
side view front view
Additional clearances for wall, door, and floor moldings may be required
or if external exhaust elbow is used.
ix,
5-3/8"
(13.7 cm)
(94.0 cm)
NOTE: Gas lines
located 1-1/2"
inward from
adjacent side.
5-1/2" (14.0 cm)
top dryer
exhaust
top dryer
gas line
37"
(13.i cm)
5-3/8"
bottom
gas line
\
dryer
13-1/2"
(34.3 cm)
41"
(104.1 cm)
3-1/8"
(7.9 cm)
bottom
Back View dryer
exhaust
27" (68.6 cm)
door
t
76-3/4"
(195 cm)
approx. 1"
(2.5 cm)
Side View
5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
IMPORTANT: The dryer must be electrically grounded in
accordance with local codes and ordinances or, in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70,
latest edition.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
[] A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit
is required. A time-delay fuse or circuit breaker isalso
recommended. It is recommended that a separate circuit
serving only this dryer be provided.
Recommended Ground Method
The dryer, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSl/NFPA 70, latest edition.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of a malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug.The plug must be
plugged into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.
WARNING: improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE INSTRUCTIONS
(:(ii¸, {}siil};,'}
IMPORTANT: The dryer must be electrically grounded in
accordance with local codes and ordinances or, in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70,
latest edition.
The National Electrical Code requires a 4-wire supply connection
for homes built after 1996, dryer circuits involved in remodeling
after 1996, and all mobile home installations.
if codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine
that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
[] A four-wire or three-wire, single-phase, 120/240 volt, 60 Hz,
AC only electrical supply (or four-wire or three-wire,
120/208 volt, if specified on the model/serial rating plate) is
required on a separate, 30-amp circuit, fused on both sides of
the line. A time-delay fuse or circuit breaker is recommended.
Recommended Ground Method
it is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformity with the National Electrical Code, ANSl/NFPA 70,
latest edition, and all local codes and ordinances.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of a malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the dryer.
WARNING" Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: Observe all governing codes and ordinances.
This installation must conform with all local codes and
ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1/NFPA 54.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
The design of this dryer has been certified by CSA International
for use at altitudes up to 10,000 feet (3048 m) above sea level at
the B.T.U. rating indicated on the model/serial plate. Burner input
adjustments are not required when the dryer is operated up to
this elevation.
When installed above 10,000 feet (3048 m), a four percent (4%)
reduction of the burner B.T.U. rating shown on the model/serial
plate is required for each 1,000 foot (305 m) increase in elevation.
For assistance when converting to other gas types and/or
installing above 10,000 feet (3048 m) elevation, contact your
local service company.
Type of Gas
This dryer is equipped for use with natural gas. It is design-
certified by CSA International for L.R (propane and butane) gases
with appropriate conversion. No attempt shall be made to convert
the dryer from the gas specified on the serial/rating plate for use
with a different gas without consulting the serving gas supplier.
Conversion must be done by a qualified service technician.
Gas conversion kit part numbers are listed on the gas valve
burner base.
Gas Supply Line
Recommended method
[] Provide a gas supply line of 1/2"rigid (IPS) pipe to the dryer
location. Pipe joint compounds that resist the action of LP gas
must be used. Do not use TEFLON _'ttape. With LP gas,
piping or tubing size can be 1/2"minimum. Usually, LP gas
suppliers determine the size and materials used in the system.
Alternate method
[] The gas supply may also be connected using %" approved
copper or aluminum tubing. Ifthe total length of the supply
line is more than 20 feet (6.1 m), larger tubing wilt be required.
If using natural gas, do not use copper tubing. Pipe joint
compounds that resist the action of LP gas must be used.
Flexible metal appliance connector
[] It is recommended that a new flexible stainless steel gas line,
design-certified by CSA International, be used for connecting
the dryer to the gas supply line. (The gas pipe which extends
through the lower rear of the dryer is provided with 3A"mate
pipe thread.)
[] Do not kink or damage the flexible stainless steel gas line
when moving the dryer.
Rigid pipe connection
The rigid pipe connection requires a combination of pipe fittings
to obtain an in-line connection to the dryer.
[][]Must include a shutoff valve:
The supply line must be equipped with a manual shutoff
valve. In the U.S., the valve must be installed within 6 ft. (1.8
m) of dryer in accordance
with National Fuel Gas
B D
Code, ANSI Z223.1. In
Canada, an individual
manual shutoff valve must
be installed in accordance
with the B149 installation
codes CAN/CGA B149.1
and CAN/CGA B149.2.
This valve should be
located in the same room
as the dryer. It should be in
A. Gas supply line
B. Shutoff valvein "open" position
C. To dryer
D. NPT 1/8" min. plugged tapping
a location that allows ease of opening and closing. Do not
block access to shutoff valve. The valve is for turning on or
shutting off gas to the dryer.
Installed in a confined area:
Ifthe dryer is installed in a confined area such as a bathroom,
provision must be made for enough air for combustion and
ventilation. Check governing codes and ordinances or refer to
the "Recessed Area Installation Instructions" in the "Location
Requirements" section.
1-®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
7
Gas Supp}y Pressure Testing
A 1/8"NPT minimum plugged tapping, accessible for gauge
testing, must be installed immediately upstream of the installed
shut-off valve to the dryer.
The dryer must be disconnected from the gas supply piping
system during any pressure testing of the system at test
pressures in excess of 1Z_psig.
Plan installation to use the fewest number of elbows and turns.
ExhaustAirFlow
A. Good
B.Better
Allow as much room as possible when using elbows or making
turns. Bend vent gradually to avoid kinking.
Vent outlet is located at the center of the bottom dryer back.
The vent can be routed up, down, left, right, behind the dryer,
or straight out the back of the dryer.
Vent System Length
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
[] The dryer vent must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
[] Do not use an exhaust hood with a magnetic latch.
[] Do not install flexible metal vent in enclosed walls, ceilings,
or floors.
[] 4" (10.2 cm) heavy metal vent and clamps must be used.
[] Use clamps to seat all joints. Vent must not be connected or
secured to the dryer with screws. Do not use duct tape.
IMPORTANT: Observe all governing codes and ordinances.
Use a heavy metal vent. Do not use plastic or metal foil vent.
Rigid metal vent is recommended to prevent crushing and
kinking.
Flexible metal vent must be fully extended and supported when
the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow
and poor performance.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home or business.
Exhaust hood must be at least 12" (30.5 cm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks, or bushes).
If using an existing vent system, clean lint from the entire length
of the system and make sure exhaust hood is not plugged with
lint. Replace any plastic or metal foil vent with rigid metal vent.
Maximum length of vent system depends upon the type of vent
used, number of elbows, and type of exhaust hood. The
maximum length for rigid vent is shown in the chart.
Maximum Vent Length
4" (10.2 cm) Diameter Exhaust Hoods
Rigid Metal Vent
No. of 90 ° turns Box Hood and Louvered Style Angled Hood Style
O 130 ft. (39.6 m) 129 ft. (39.3 m)
1 125 ft. (38.1 m) 119 ft. (38.3 m)
2 115 ft. (35.1 m) 109 ft. (33.2 m)
3 106 ft. (32.3 m) 100 ft. (30.5 m)
4 98 ft. (29.9 m) 92 ft. (28.0 m)
For vent systems not covered by the vent specification chart,
see your parts distributor.
If dryer is installed in a confined area, such as a bedroom
or bathroom, provision must be made for enough air
for combustion and ventilation. (Check governing codes and
ordinances.) See "Recessed Area Installation Instructions" in the
"Location Requirements" section.
Multiple Dryer Venting
[] A main vent can be used for venting a group of dryers. The
main vent should be sized to remove 200 CFM of air per dryer
(min. static pressure of 0.06 inch water column TOTAL).
Large-capacity lint screens of proper design may be used in
the main vent if checked and cleaned frequently. The room
where the dryers are located should have make-up air equal
to or greater than the CFM of all the dryers in the room.
[] Back-draft Damper Kits, Part No. 3391910, are available from
your dealer or distributor and should be installed in the vent of
each dryer to prevent exhausted air from returning into the
dryers and to keep the exhaust in balance within the main
vent. Unobstructed air openings are required.
Each vent should enter the main vent at an angle pointing in the
direction of the airflow. Vents entering from the opposite side
should be staggered to reduce the exhausted air from interfering
with the other vents.
The maximum angle of each vent entering the main vent should
be no more than 30 °.
air flow _ B 4--
If an exhaust hood cannot be used:
B
2 ft. (61 cm) min.
above highest
point of building
E.180°sweepelbow
F.Verticalvent
G.Roof
The outside end of the main vent should have a sweep elbow
directed downward. If the main vent travels vertically through the
roof, rather than through the walt, install a 180° sweep elbow on
the end of the vent at least 2 feet (61 cm) above the highest part
of the building. The opening in the wall or roof shall have a
diameter 1/2" (1.3 cm) larger than the vent diameter. The vent
should be centered in the opening.
Do not install screening or cap over the end of the vent.
A.Individualdryervent
B. Mainvent
Keep air openings free of dry cleaning fluid fumes. Fumes create
acids which, when drawn through the dryer heating units, can
damage dryers and loads being dried.
A clean-out cover should be located on the main vent for periodic
cleaning of the vent system.
9
INSTALLATIONINSTRUCTIONS- GASDRYER
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. Remove red cap from gas pipe.
2. Connect gas supply to dryer. Use pipe-joint compound
resistant to the action of LR gas for gas connections. If
flexible metal tubing is used, be certain there are no kinks.
If necessary for service, open the toe panel. Use a putty knife
to press on the toe panel locks located at the upper corners
of the toe panel. Pull downward on the toe panel to open. Toe
panel is hinged at the bottom.
3. Open the shutoff valve in the gas supply line.
4. Test all connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct any
leak found.
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet
on rear of dryer. If connecting to existing vent, make sure the
vent is clean. The dryer vent must fit over the dryer exhaust
outlet and inside the exhaust hood. Make sure the vent is
secured to exhaust hood with a 4" (10.2 cm) clamp.
2. Using two or more people, move dryer to desired installation
location. Do not crush or kink vent. Make sure dryer is level.
3. Check that there are no kinks in the flexible gas line.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. With dryer in final position, place level on top of the dryer, first
side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.
2. Using a Torx T20 security driver, open the control panel and
rest it on the bottom edge of the opening.
3. For added security between the upper dryer and the collar,
insert the cotter hair pin through the connecting bolt.
4. Close the control panel.
5. Plug into a grounded 3 prong outlet.
6. Check dryer operation.
Select a full heat cycle, let the dryer run for at least five
minutes. Dryer will stop when time is used up.
NOTE: Dryer door must be closed for dryer to operate. When
door is opened, dryer stops, but time continues to count
down. To restart dryer, close door and resetect cycle.
7. If the burner does not ignite and you can feel no heat inside
the dryer, shut off dryer for five minutes. Check that all supply
valve controls are in "ON" position and that the electrical cord
is plugged in. Repeat five-minute test.
INSTALLATIONINSTRUCTIONS-ELECTRICDRYER
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
10
Power Supply Cord Method - U.S. Only
This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground conductor is
permanently connected to the neutral conductor (white wire)
within the dryer. If the dryer is installed with a 4-wire electrical
supply connection, the neutral ground conductor must be
removed from the external ground connector (green screw), and
secured under the neutral terminal (center or white wire) of the
terminal block. When the neutral ground conductor is secured
under the neutral terminal (center or white wire) of the terminal
block, the dryer cabinet is isolated from the neutral conductor.
Power Supply Cord Method = U.S. Only
[] If local codes do not permit the connection of a neutral ground
wire to the neutral wire, see "Optional 3-wire connection"
section.
[]A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through the
neutral conductor is prohibited. Grounding through the neutral
is prohibited for (1) new branch-circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4) areas where local
codes prohibit grounding through the neutral conductors.
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect power.
....s 0
A. External ground conductor screw
B. Tab
C. Terminal block cover
D. Hold-down screw
2=
Remove hold-down screw and the terminal block cover.
3.
Assemble 3A" UL-listed strain relief (UL marking on strain
relief) into the hole below the terminal block opening. Tighten
strain relief screws just enough to hold the two clamp
sections together. Install power supply cord through the
strain relief.
A. Strain relief clamp sections
B. Dryer cabinet
C. Strain relief screws
4=
Complete installation following instructions for your type of
electrical connection:
• Four-wire (recommended method)
Three-wire (if four-wire ts not available)
Power Supply Cord,
Four=wire electrical connection:
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground wire
from the external ground conductor screw.
Fasten under center, silver-colored
terminal block screw.
7. Connect the ground wire of the power
supply cord to the external ground
conductor screw. Tighten screw.
B
Y
D
8. Connect the neutral wire (white or center)
of the power supply cord under the center
screw of the terminal block. Tighten
screw.
9. Connect the other wires to outer terminal
G
A. Spade terminals with D.Neutral (white)
upturned ends E.Ring terminals
B. Neutral F. Ground wire
C.¾" UL-fisted strain G.Ground prong
relief
F .... E ''_
block screws. Tighten screws.
10. Tighten strain relief screws.
11. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
Four-wire power supply cord must have four, No. 10 copper wires and match a four-wire
receptacle of NEMA Type 14-30R. The fourth wire (ground conductor) must be identified
by a green cover and the neutral conductor by a white cover.
0
E ......................
A.Externalgroundconductorscrew
B.Applianceneutralgroundwire
C.Centerterminalblockscrew
D.Outerterminalblockscrews
E.Strainreliefscrew
F. Neutral(centerwire)
G.Groundwire
Power Supply Cord,
Three=wire electrical connection:
_m A ....................
Thisbladeconnectedto B
.....thisconductor. ...................................
E D C
A. Spade terminals with upturned ends
B.Ring terminals
C.Neutral (white or center)
D. ¾" UL-Iisted strain relief
E. Neutral
Three-wire power supply cord must
have three, No. 10 copper wires and
match a three-wire receptacle of NEMA
Type 10-30R.
Use this method where local codes permit connecting
neutral ground wire to neutral wire: A ................................ _Z_
5. Loosen or remove the center terminal l_l _.__ O__1
block screw. F .....................
Connect the neutral wire (white or center)
of the power supply cord to the center,
silver-colored terminal screw of the
terminal block. Tighten screw.
E ..........
7. Connect the other wires to outer terminal _ .........
8. Tighten strain relief screws.
block screws. Tighten screws. _ C
9. Insert tab of the terminal block cover into D ............
slot of the dryer rear panel. Secure cover
with hold-down screw.
A. External ground conductor screw
B. Center terminal block screw
C. Outer terminal block screws
D. Strain relief screw
E. Neutral (center wire)
F.Appliance neutral ground wire
Use this method where local codes do not permit
connecting neutral ground wire to neutral wire:
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground wire
from the external ground conductor
A...............!.... C
g ............
I I \l
screw. Connect the appliance neutral
ground wire and the neutral wire (white or
center) of the power supply cord under
the center, silver-colored terminal block
screw. Tighten screw.
7. Connect the other wires to outer terminal
block screws. Tighten screws.
8. Tighten strain relief screws.
E
9. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
F ..................
10. After reattaching the terminal cover,
connect a separate copper ground wire
from the external ground conductor screw
to an adequate ground.
If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.
A. Separate copper ground wire
B. External ground conductor screw
C. Appliance neutral ground wire
D. Center terminal block screw
E. Outer terminal block screws
F. Strain relief screw
G. Neutral (center wire)
B
12
Direct Wire Method - U.S. Only
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (si{ver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrica{ connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct wire cable must match power supply (4-wire or 3-wire)
and be:
[] Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit.
All current-carrying wires must be insulated.
[] 10-gauge solid copper wire (do not use aluminum).
[] At least 5 ft. (1.52 m) long.
1. Disconnect power.
2. Remove hold-down screw and terminal block cover.
D
/
........,s
A. External ground conductor screw
B. Tab
C. Terminalblock cover
D. Hold-down screw
3=
Install ,_A"conduit connector into the hole below the terminal
block opening. Connect flexible metallic conduit and tighten
connector screw. Install direct wire cable through the flexible
metallic conduit.
j
B
A. Conduitconnector
B.Dryercabinet
C. Connectorscrew
4=
Complete installation following instructions for your type of
electrical connection:
• Four-wire (recommended method)
Three-wire (if four-wire is not available)
Direct Wire,
Four=wire e{ectrical connection:
to { °_r_e_jof/_
_ 5" (12.7cm) _
Shape ends ground wireat5" (12.7 cm). Cut11A"
ofwiresinto (3.8 cm) from3 remaining wires. Strip
ahook. insulationback1"(2.5 cm).
A. 3/4"conduitconnector
fromendof cable.Leavegreenor bare
Strip 5" (12.7 cm) ofoutercovering
B.Neutral(whiteorcenter)
C.Groundwire(greenor bare)
D. lO-gauge,3wirewith groundwire
in flexiblemetallicconduitO
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground
wire from the external ground conductor
screw. Fasten under center, silver-
colored terminal block screw.
7° Connect the ground wire (green or bare)
of the direct wire cable to the external
ground conductor screw. Tighten screw.
8. Place the hooked end of the neutral wire
(white or center) of the direct wire cable
under the center screw of the terminal
block (hook facing right). Squeeze hook
end together. Tighten screw.
9. Place the hooked ends of the other
direct wire cable wires under the outer
terminal block screws (hook facing right).
Squeeze hooked ends together. Tighten
screws.
10. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
C
F
E¸
D
A. External ground conductor screw
B.Appliance neutral ground wire
C.Center terminal block screw
D.Outer terminal block screws
E.Neutral (center wire)
F.Green or bare ground wire
13
Direct Wire,
Three=wire electrical connection:
Three wire with ground wire: green or bare
wire cut short. Wire is not used. Dryer is
grounded through neutral conductor.
A 1"(2.5cm)
ofwires
to strippedof
disconnect insulation
box _
Use this method where local codes permit
connecting neutral ground wire to
neutral wire:
5. Loosen or remove the center terminal
block screw.
6. Place the hooked end of the neutral wire
(white or center) of the direct wire cable
under the center screw of the terminal
block (hook facing right). Squeeze
hooked end together. Tighten screw.
7. Place the hooked ends of the other
direct wire cable wires under the outer
terminal block screws (hook facing right).
Squeeze hooked ends together. Tighten
screws.
8. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
C
A. External ground conductor screw
B. Center terminal block screw
C. Outer terminal block screws
D. Neutral (center wire)
E.Appliance neutral ground wire
Be
C
(8.9 cm)
Strip 31½''(8.9 cm) of outer
Shapeends
of wiresinto
a hook.
A. 3/4"conduit connector
B. Neutral (white or center)
C. lO-gauge, 3 wire with ground wire
in flexible metallic conduit
covering from end of cable. Strip
insulation back 1" (2.5 cm). If using
3 wire cable with ground wire, cut
green or bare wire even with outer
covering.
Use this method where local codes do
not permit connecting neutral ground
wire to neutral wire:
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground wire
from the external ground conductor screw.
Connect the appliance neutral ground wire
and the neutral wire (white or center) of the
direct wire cable under the center, silver-
colored terminal block screw. Tighten
screw.
7. Connect the other wires to outer terminal
block screws. Tighten screws.
8. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
9. After reattaching the terminal cover,
connect a separate copper ground wire
from the external ground connector screw
to an adequate ground.
If codes permit and a separate ground wire
is used, it is recommended that a qualified
electrician determine that the ground path
is adequate.
A......... C
A. Separate copper ground wire
B. External ground conductor screw
C. Appliance neutral ground wire
D. Center terminal block screw
E. Outer terminal block screws
F. Neutral (center wire)
14
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4" (10.2 cm) clamp.
2. Using two or more people, move dryer to desired installation
location. Do not crush or kink vent. Make sure dryer is level.
1. With dryer in final position, place level on top of the dryer, first
side to side; then front to back. Ifthe dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.
2. Using a Torx T20 security driver, open the control panel and
rest it on the bottom edge of the opening.
ELECTRONICCONTROL SETUP
3. For added security between the upper dryer and the collar,
insert the cotter hair pin through the connecting bolt.
4. Close the control panel.
5. Plug in dryer or reconnect power.
6 Check dryer operation.
Select a full heat cycle, let the dryer run for at least five
minutes. Dryer wilt stop when time is used up.
NOTE: Dryer door must be closed for dryer to operate. When
door is opened, dryer stops, but time continues to count
down. To restart dryer, close door and reselect cycle.
7. Now start the dryer and allow it to complete a full heat cycle
to make sure it is working properly.
See Tech Sheet for information on setup.
MAINTENANCE INSTRUCTIONS
Maintenance instructions:
mClean lint screen after each cycle.
mRemoving accumulated lint:
• From inside the dryer cabinet:
Lint should be removed every 2 years or more often,
depending on dryer usage. Cleaning should be done
by a qualified person.
• From the exhaust vent:
Lint should be removed every 2 years, or more often,
depending on dryer usage.
mKeep area around dryer clear and free from combustible
materials, gasoline and other flammable vapors and liquids.
mKeep dryer area clear and free from items that would obstruct
the flow of combustion and ventilation air.
If dryer does not operate, check the following:
[] Electrical supply is connected.
[] Circuit breaker is not tripped or house fuse is not blown.
[] Door is closed.
[] Controls are set in a running or "ON" position.
[] Cycle has been selected.
[] For gas dryers, check that gas supply shutoff valves are set
in open position.
If you need assistance:
The Commercial Laundry Support Center will answer any
questions about operating or maintaining your dryer not covered
in the Installation Instructions. Just dial 1-800 NO BELTS
(1-800-662-3587) -- the call is toll free.
When you call, you will need the dryer model number and serial
number. Both numbers can be found on the serial-rating plate
located in the dryer door well.
15
MAYTAG COMMERCIAL WASHE DRYER,STACKED DRYER/
DRYE COMMERCIAL STACK LAUNDRY, AND MULTi-LOAD
COiN OPERATED COMMERCIAL WASHERS AND DRYERS
WARRANTY
LiMiTED WARRANTY ON PARTS
For the first five years from the date of purchase, when this commercial appliance is installed, maintained and operated according to the
instructions attached to or furnished with the product, Maytag brand of Whirlpool Corporation (thereafter "Maytag") will pay for factory
specified parts or original equipment manufacturer parts to correct defects in materials or workmanship. Proof of original purchase date
is required to obtain service under this warranty.
ITEMS MAYTAG WILL NOT PAY FOR
1. All other costs including labor, transportation, or custom duties.
2. Service calls to correct the installation of your commercial appliance, to instruct you how to use your commercial appliance, to
replace or repair fuses, or to correct external wiring or plumbing.
3. Repairs when your commercial appliance is used for other than normal, commercial use.
4. Damage resulting from improper handling of product during delivery, theft, accident, alteration, misuse, abuse, fire, flood, acts of
God, improper installation, installation not in accordance with local electrical or plumbing codes, or use of products not approved
by Maytag.
5. Pickup and Delivery. This commercial appliance is designed to be repaired on location.
6. Repairs to parts or systems resulting from unauthorized modifications made to the commercial appliance.
7. The removal and reinstallation of your commercial appliance if it is installed in an inaccessible location or is not installed in
accordance with published installation instructions.
8. Chemical damage is excluded from all warranty coverage.
9. Changes to the building, room, or location needed in order to make the commercial appliance operate correctly.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATIONS OF REMEDIES
CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED
HEREIN. iMPLiED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABiLiTY OR FITNESS FOR A PARTICULAR PURPOSE,
ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. WHIRLPOOL SHALL NOT BE LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LiMiTATION
OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS, SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES
YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE OR PROVINCE
TO PROVINCE.
If you need service, please contact your authorized Maytag Commercial Laundry distributor. To locate your authorized Maytag
Commercial Laundry distributor, or for web inquiries, visit www.MaytagCommercialLaundry.com.
For written correspondence:
Maytag Commercial Laundry Service Department
2000 M-63 North
Benton Harbor, Michigan 49085 USA
9/07
16
P P P
SECURITEDELASECHEUSE
Votre securite et celle des autres est tres importante.
Nous donnons de nombreux messages de s_curite importants dans ce manuel et sur votre appareil m_nager. Assurez-vous de
toujours lire tousles messages de s_curite et de vous y conformer.
Ce symbole d'alerte de s_curit_ vous signale les dangers potentiels de d_c_s et de blessures graves h vous
et h d'autres.
Voici le symbole d'alerte de s_curit&
Tousles messages de securite suivront le symbole d'alerte de s_curite et le mot "DANGER" ou
"AVERTISSEMENT". Ces mots signifient •
Risque possible de d_cbs ou de blessure grave si vous ne
suivez pas imm_diatement les instructions.
Risque possible de d_cbs ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de s_curite vous diront quel est le danger potentiel et vous disent comment r_duire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
m On recommande que le proprietaire place les instructions h I'usage du client hun endroit bien visible, pour le cas oQ le client
percevrait une odeur de gaz. Ces renseignements doivent _tre obtenus aupr_s de votre foumisseur de gaz.
m Placer I'avertissement qui suit hun endroit bien visible.
POUR VOTRE SE_CURITE_
Ne pas entreposer ni utiliser de I'essence ou d'autres produits liquides ou gazeux inflammables & proximit_ de cet appareil ou de
tout autre appareil _lectrom_nager.
AVERTISSEMENT • Pour votre securite, les renseignements darts ce manuel doivent
_tre observes pour reduire au minimum les risques d'incendie ou d'explosion ou pour
eviter des dommages au produit, des blessures ou un deces.
- Ne pas entreposer ou utiliser de Fessence ou d'autres vapeurs ou liquides
inflammables h proximite de cet appareil ou de tout autre appareil electromenager.
-QUE FAIRE DANS LE CAS D'UNE ODEUR DE GAZ :
®Ne pas tenter d'allumer un appareil.
• Ne pas toucher a un commutateur electrique; ne pas utiliser le telephone se trouvant
sur les lieux.
Evacuer tous les gens de la piece, de I'edifice ou du quarrier.
Appeler immediatement le fournisseur de gaz d'un telephone voisin. Suivre ses
instructions.
h. defaut de joindre votre fournisseur de gaz, appeler les pompiers.
- L'installation et I'entretien doivent _tre effectues par un installateur qualifie, une
agence de service ou le fournisseur de gaz.
17
AVERTISSEMENT : L'odorat ne permet pas toujours la d6tection d'une fuite de gaz.
Les distributeurs de gaz recommandent I'emploi d'un d6tecteur de gaz (homologation UL ou CSA).
Pour d'autre information, contacter le fournisseur de gaz local.
En cas de d6tection d'une fuite de gaz, ex6cuter les instructions "Que faire dans le cas d'une odeur de gaz".
IMPORTANTES INSTRUCTIONS DE SI_CURITI_
AMERTISSEM ENT • Pour r6duire le risque d'incendie, de choc 61ectrique ou de blessure Iors de I'utilisation de
la s6cheuse, il convient d'observer certaines pr6cautions el6mentaires dont les suivantes :
• Lire toutes les instructions avant d'utiliser la s6cheuse.
• Ne pas placer des articles expos6s aux huiles de cuisson
dans votre secheuse. Les articles contamin6s par des
huiles de cuisson peuvent contribuer & une r6action
chimique qui pourrait causer a la charge de s'enflammer.
• Ne pas faire s6cher dans la machine des articles qui ont
d6j& et6 nettoy6s, lav6s, imbib6s, ou tach6s d'essence,
de solvants pour nettoyage a sec, d'autres substances
inflammables, ou de substances explosives puisqu'elles
d6gagent des vapeurs qui peuvent provoquer un
incendie ou une explosion.
• Ne pas permettre & des enfants de jouer sur ou
I'int6rieur de la s6cheuse. Une surveillance etroite est
n6cessaire Iorsque la s6cheuse est utilis6e pros d'eux.
• Avant d'enlever la s6cheuse du service ou la jeter, enlever
la porte du compartiment de s6chage.
• Ne pas mettre la main dans la s6cheuse si le tambour est
en mouvement.
• Ne pas installer ni entreposer la s6cheuse oQ elle sera
expos6e aux intemp6ries.
• Ne pas jouer avec les commandes.
CONSERVEZ CES INSTRUCTIONS
• Ne pas reparer ni remplacer une piece de la secheuse ou
essayer d'en faire I'entretien & moins d'une recommandation
specifique dans le guide d'utlilisation et d'entretien, ou
publi6e dans les instructions de r6paration par I'utilisateur
que vous comprenez et pouvez ex6cuter avec competence.
• Ne pas utiliser un produit assouplissant de tissu ou des
produits pour 61iminer la statique & moins qu'ils ne soient
recommandes par le fabricant du produit assouplissant de
tissu ou du produit.
• Ne pas utiliser la chaleur pour faire secher des articles
fabriqu6s avec du caoutchouc mousse ou des mat6riaux
semblables.
• Nettoyer le filtre &charpie avant et apr_s chaque charge.
• Ne pas laisser la charpie, la poussi_re, ou la salet6
s'accumuler autour du syst_me d'6vacuation ou autour de
I'appareil.
• Un nettoyage p6riodique de I'int6rieur de la s6cheuse et du
conduit d'6vacuation doit _tre effectu6 par une personne
qualifi6e.
• Voir les instructions d'installation pour les exigences de
liaison de I'appareil &la terre.
IMPORTANT : L'installation du gaz dolt se conformer aux codes Iocaux, ou en I'absence de codes Iocaux, au code canadien
d'installation B149.1 du gaz naturel ou du propane.
La secheuse doit 6tre 61ectriquement reliee & la terre conformement aux codes Iocaux, ou en I'absence de codes Iocaux, au Code
canadien de I'electricit6, CSA C22.1.
18
EXIGENCESD'INSTALLATION
Rassembter les outils et pi_ces necessaires avant de commencer
I'instatlation. Life et respecter les instructions d'instattation
fournies avec chacun des outits de cette liste.
OutiHage n_cessaire
m Clehtubede8"oul0" [] Cle_douillede5/16"
[] Cle _ molette de 8" ou 10" [] Brides de fixation
[] Tournevis h lame plate [] Compose d'etancheite des
[] Tournevis Phillips raccords filetes - r_sistant
[] Cle _ molette avec au propane
ouverture jusqu'_ 1" [] Pistolet _ calfeutrage et
(2,5 cm) ou cte h douitle compose de catfeutrage
hexagonale de 1" (25 mm) (pour I'instatlation d'un
[] Tournevis de securite
TORX_'7--20 d'evacuation)
[] Niveau
Pi_ces fournies
Retirer le sac de pi_ces du tambour de la secheuse.
Verifier la presence de toutes les pi_ces.
[] Vis cannelees de 10-32 x
5/16 po (4)
[] Goupitle fendue (2)
nouveau circuit
[] Pince
[] Couteau h mastic
[] Veilter h ce que les bords inferieurs de la caisse ainsi que
I'arri_re et les c6tes inf_rieurs de la secheuse soient exempts
d'obstructions, afin de permettre le passage adequat de I'air
de combustion. Voir la section "instructions pour rinstallation
dans un encastrement" pour I'espace de degagement
minimal.
REMARQUE :
[] La secheuse ne dolt pas _tre installee en un endroit o_ etle
serait exposee h de I'eau ou aux intemperies.
[] Cette secheuse ne dolt pas _tre instattee dan un placard muni
d'une porte.
instructions pour {'installation dans
un encastrement
Cette secheuse peut _tre installee dans un encastrement. Les
distances de separation minimales sont mentionnees h I'arri_re
de la secheuse.
Le circuit d'evacuation de la secheuse dolt _tre retie h I'exterieur.
Risque d'explosion
Garder {es mati_res et les vapeurs inflammables, teile
que I'essence, loin de la s_cheuse.
Ne pas installer darts un garage.
Le non=respect de ces instructions peut causer
un d_c_s, une explosion ou un incendie.
Pour I'installation d'une s_cheuse & gaz :
IlVlPORTANT : Respecter les dispositions de tousles codes
et r_glements en vigueur.
[] Determiner les exigences des codes : Certains codes limitent
ou prohibent I'installation d'une secheuse dans un placard ou
une chambre h coucher. Consulter rinspecteur local des
b_timents.
1@ TORX est une marque d_pos_e de Textron Innovations, Inc.
19
Distances de s_paration minimales
Encastre I 2P° I 0po I 12po I -- I
Arri_re C6t&s Dessus Avant
(0 cm) (30 cm)
--_1_ 2 po (5 cm).__
12po .... 0po
(30 cm) _ (0 cm)
O
O
0
po (0 cm)-_ _1_-- -:_1_ I_1(--0 po (0 cm)
Encastrement, Encastrement,
vue laterale vue avant
On doit pr6voir un espacement additionnel pour tenir compte 6ventuellement
des moulures du mur, de la porte et du plancher, ou si le circuit d'6vacuation
comporte un coude.
Dimensions du produit
Bouche de
d6charge
sup6rieure
canalisation \
de gaz
sup6rieure\
5-3/8 po
(13,7 cm)
37 po
(94,0 cm)
\
5-3/8 po
(13,1 cm)
T
NOTE : Canalisation canalisation
de gaz & 1-1/2 po de gaz
(3,8 cm) vers inf6rieure
I'int6rieur du
c6t6 adjacent
oEa
Vue artiste
13-1/2 po
(34,3 cm)
41 po
(104,1 cm)
3-1/8 po
(7,9 cm)
Bouche de
d6charge
inf6rieure
5-1/2 po (14,0 cm)
Porte
27 po (68,6 cm)
t
76-3/4 po
(195 cm)
10-1/2 po
(26,7 cm)
--._
@--
7-1/2 po--_
(19,1 cm)
O
23-3/4 po 29-1/4 po
(60,3 cm) (74,3 cm) approx. 1 po
(2,5 cm)
20
Vue laterate