Front-Loading Washer
PRODUCT MODEL NUMBERS
MHW3000B, MHW3500B, MHW4000B, MHW4200B, MHW6000A, MHW7000A,
MHW8000A, MHW3100D, MHW4100D, MHW4300D, MHW4400D, MHW5100D,
MHW5400D, MHW7100D, MHW8100D
Washer Dimensions: Undercounter installation -
washer only:
15
/16"
52
(1345 mm)
3215/16"
(837 mm)
383/4" - 393/4"
(948 mm - 1010 mm)
Recessed or closet installation -
stacked washer and dryer
27"
(686 mm)
Recessed area or closet installation (washer only):
3"
2
48 in.
(310 cm2)
2
24 in.
(155 cm2)
(76 mm)
3"
(76 mm)
1"
(25 mm)
(152 mm)
(152 mm)
(1943 mm)
(127 mm)
* Add spacing of 1" (25 mm) on all sides of washer/dryer.
6"
6"
761/2"
5"
3"
(76 mm)
2
48 in.
(310 cm2)
2
24 in.
(155 cm2)
3"
(76 mm)
1"
(25 mm)
(102 mm)
* Add spacing of 1" (25 mm) on all sides of washer.
4"
W10631155A
04/2014
4"
(102 mm)
1"
(25 mm)
7"
(178 mm)
14"
(356 mm)
Custom cabinet installation (washer only):
All dimensions show recommended spacing allowed, except for
closet door ventilation openings which are the minimum required.
For each arrangement, consider allowing more space for ease of
installation and servicing, and spacing for companion appliances
and clearances for walls, doors, and oor moldings.
Space must be large enough to allow door to fully open.
Add spacing of 1" (25 mm) on all sides of washer to reduce
noise transfer. If a closet door or louvered door is installed, top
and bottom air openings in door are required.
** Recommended 4" (102 mm), minimum 1.5" (38 mm)
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is
recommended that a separate circuit serving only this appliance be provided.
DRAIN SYSTEM
Drain system can be installed using a oor drain, wall standpipe, oor standpipe, or laundry tub. Select method you need.
IMPORTANT: To avoid siphoning, only 4.5" (114 mm) of drain hose should be inside standpipe. Always secure drain hose
with cable tie.
Floor standpipe drain system
4.5"
(114 mm)
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum
carry-away capacity: 17 gal. (64 L) per minute. A 1/4" (6 mm)
diameter to 1" (25 mm) diameter Standpipe Adapter Kit is
available (Part Number 3363920). Top of standpipe must be at
least 30" (762 mm) high; install no higher than 96" (2.44 m) from
bottom of washer. If you have an overhead sewer and need to
pump higher than 96" (2.44 m), a sump pump and associated
hardware are needed. See “Alternate Parts”.
Wall standpipe drain system
4.5"
(114 mm)
See requirements for oor standpipe drain system.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Laundry tub drain system
4.5"
(114 mm)
min.
30"
(762 mm)
Minimum capacity: 20 gal. (76 L). Top of laundry tub must
be at least 30" (762 mm) above oor; install no higher than
96" (2.44 m) from bottom of washer.
Floor drain system
Floor drain system requires a Siphon Break Kit (Part Number
285834), 2 Connector Kits (Part Number 285835), and an
Extension Drain Hose (Part Number 285863) that may be
purchased separately. See “Alternate Parts”. Minimum siphon
break height: 28" (710 mm) from bottom of washer. (Additional
hoses may be needed.)