Maytag MGS5875BDS, MGS5752BDB, MGS5752BDS, MGS5752BDW Dimension Guide

30" (76.2 cm) Slide-In Gas Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
CABINET OPENING DIMENSIONS
MGS5752BD MGS5875BD
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10526091A
11/6/12
*
C
k
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is shielded by not less than
¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
Type of Gas
Natural Gas: This range is design-certified by CSA International for use with Natural gas or, after proper
conversion, for use with LP gas.
This range is factory set for use with Natural gas. See “Gas Conversions” section. The model/serial rating plate located behind the storage drawer on the right-hand side oven frame has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP gas conversion: Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section.
Gas Supply Line
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON
®†
tape.
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal tubing when moving the range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the range. The rigid pipe must be level with the range connection. All strains must be removed from the supply and fuel lines so range will be level and in line.
Must include a shutoff valve: The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface. Range may be installed with zero clearance to combustible construction at the rear and on the sides below the cooktop.
Electrical
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time­delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded.
A
B
H
E
C
D
I
I
F
G
A. 13" (33.0 cm) upper cabinet depth B. 30" (76.2 cm) min. opening width C. For minimum clearance to the top of the cooktop, see NOTE. D. 23
" (59.1 cm) opening depth
¹⁄₄
E. 30" (76.2 cm) min. opening width
F. Electrical and gas supply - 5½" (14.0 cm) min. from either cabinet, 10" (25.4 cm) max.
from floor. Nothing located in shaded area can extend more than 2¼" (5.7 cm) from bac
wall or range will not slide all the way back. Grounded outlet must be flush mounted. G. Cabinet door or hinge should not extend into cutout. H. 18" (45.7 cm)
I. 3" (7.6 cm) min. clearance from both sides of the range to the side wall or other
combustible material.
A
F
B*
D
E**
A. 30
" (78.1 cm)
³⁄₄
B. 35
" (90.8 cm) height to underside
³⁄₄
of cooktop edge with leveling legs screwed all the way in*
C. Model/serial rating plate (located
behind the storage drawer on the right-hand side of the oven frame)
D. 29
" (75.9 cm)
⁷⁄₈
E. 28
" (71.9 cm) from
⁵⁄₁₆
handle to back of range*
F. 2 3
" (60.3 cm)
³⁄₄
countertop notch to rear of cooktop
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
**When installed in a 24" (61.0 cm) base cabinet with
25" (63.5 cm) countertop; front of oven door protrudes 2¹⁄₂" (6.4 cm) beyond 24" (61.0 cm) base cabinet.