30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
MGR7662W
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10526975A
8/13/13
IMPORTANT: Range must be level after installation. Follow the instructions in the
“Level Range” section. Using the cooktop as a reference for leveling the range is
not recommended.
**Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.
**Front of door and drawer may extend farther forward, depending on styling.
Electrical Requirements
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required.
A time-delay fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only this range be
provided.
Gas Supply Line
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range
location. A smaller size pipe on longer runs may result in insufficient
gas supply. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm)
minimum. Usually, LP gas suppliers determine the size and materials
used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be
used. Do not use TEFLON
®†
tape.
Flexible metal appliance connector:
●
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to
152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal
appliance connector may be used for connecting range to the gas
supply line.
●
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance pressure regulator.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop
depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop
height.
IMPORTANT: If installing a range hood or microwave hood combination
above the range, follow the range hood or microwave hood
combination installation instructions for dimensional clearances above
the cooktop surface.
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is
covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
*30" (76.2 cm) minimum clearance between the top of the cooking platform
and the bottom of an uncovered wood or metal cabinet.
A
F
E
C
B
D
A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of cooktop, see NOTE*.
E. 30
" (76.5 cm) min. opening width
¹⁄₈
F. The shaded areas are recommended for installation of rigid
gas pipe.
G. 4
" (11.4 cm)
¹⁄₂
H. 8" (20.3 cm)
I. 17" (43.2 cm)
J. 2" (5.1 cm)
K. 4
" (11.4 cm)
¹⁄₂
L. 2" (5.1 cm) min. clearance from both sides of range to side
wall or other combustible material.
M. Grounded outlet
N. Cabinet door or hinges should not extend into the cutout.
A. 27
" (70.8 cm) max. depth with handle
⁷⁄₈
B. 36" (91.4 cm) cooktop height (max.) with leveling legs
screwed all the way in*
C. 46
" (119.1 cm) overall height (max.) with leveling
⁷⁄₈
legs screwed all the way in*
D. 29
" (75.9 cm) width
⁷⁄₈
E. 25
" (64.6 cm) depth. Back of range to front of
⁷⁄₁₆
cooktop**
F. Model/serial rating plate (located on the oven frame
behind the top left side of the oven door)
B
D
C
A
E
N
M
L
H
F
G
F
I
K
J
K