Maytag MGR5775QDW, MGR5775QDQ, MGR5775QDB, MGR5775QDS, MGR5875QDW Dimension Guide

...
www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
29 7/8"
Free Standing Gas Ranges:
MGR5775QDW, MGR5775QDQ, MGR5775QDB,
(not to scale)
MGR5775QDS, MGR5875QDW, MGR5875QDQ,
MGR5875QDB and MGR5875QDS
• Dimensions (Actual Size) •
Height of cooking surface: 35 7/8"
Height overall:
Case width:
Depth NOT including handle:
Door swing:
46 3/4" 29 7/8" 25 1/2" 20" 36"Height at full leg adjustment:
Height at 0" leg adjustment:
35 1/2"
• Additional Information •
• Units depth including door handle is 28 1/8".
46 3/4"
35 7/8"
20"
Door open
25 1/2"
• Can be installed with the back against (0") a vertical
combustible wall, and the sides below the cooktop surface against (0") combustible base cabinets.
• Electrical requirements: 120 VAC,60Hz. 15 amp
grounded circuit protection is required. Outlet must be installed flush to wall.
• Gas requirements: Gas supply line should be 3/4".
Install a manual shutoff valve in an accessible location in the gas line external to this appliance for the purpose of turning on or shutting off gas to the appliance. The appliance is shipped from the factory equipped for use with natural gas and can be converted to LP gas in the field . The maximum gas supply pressure for both LP and natural gas is 14" WC. Minimum Pressure for
Locate
electrical box
within this
shadded area
6"
22"
Wall View
(not to scale)
3 1/4"
3 1/4"
6"
Locate gas supply within this shadded
area
Natural gas is 4" WC. Minimum Pressure for LP gas is 10" WC.
• Proper operation requires use of range hood.
• Cabinetry over cooktop : 30' minimum clearance between the top of the cooking surface and the bottom
3"
of an unprotected wood or metal cabinet. 24" minimum when bottom of wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or copper.
Wall View
(not to scale)
Upper cabinets can only be 13" deep maximum. Over range cabinet is NOT
See page 2 for additional information
recommended.
30" Min.
Side clearance from cooktop to 18" above the cooktop is 3" on each side (see
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter­mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2003.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
255
Countertop
height
Range
solid arera)
30" Minimum cutout width
BN • A255B149 • • 031211 • 163243 • 39650
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• To eliminate the hazard of reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the hazard can be reduced by installing a range hood that projects horizontally a minimum of 5" beyond the bottom of the cabinets.
• For Free-standing installations the cutout opening width is 30" ± 1/16" minimum. The height of the countertop is 36" and countertop depth is 25".
Page 2
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
Free Standing Gas Ranges:
MGR5775QDW, MGR5775QDQ, MGR5775QDB, MGR5775QDS, MGR5875QDW, MGR5875QDQ,
MGR5875QDB and MGR5875QDS
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2003.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
BN • A255B149 • • 031211 • 163243 • 39650
149
Loading...