PRODUCT MODEL NUMBERS
MGD3000B, MGD4000B, MGD4200B,
MGD6000A, MGD7000A, MGD8000A
Front view: Side view:
27"
(686 mm)
1
"
38
/8
(968 mm)
3
/4
"*
(18 mm)
Gas Dryer
Back view: Recommended Installation Spacing:
Back view:
61/4"
(159 mm)
18" min.
Water inlet
(Steam Models Only)
29
7
/8"*
(457 mm)
(759 mm)
53/4"*
(146 mm)
3
/4"*
(18 mm)
Vent
Gas
(365 mm)
253/4"
(654 mm)
14
3
/8"
(156 mm)
1
/8"*
6
1
/2"*
3
(89 mm)
5"
(127 mm)
1"
(25 mm)
1"
(25 mm)
* 0" (0 mm) spacing is allowed.
NOTE: Most installations require a minimum of 5" (127 mm) clearance
behind dryer for exhaust vent with elbow. See “Venting Requirements”.
Installation spacing for recessed area or closet installation
The dimensions shown below are for the recommended spacing for this dryer.
■ Additional spacing should be considered for ease of installation and servicing.
■ Additional clearances might be required for wall, door, and oor moldings, and dryer venting.
■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are acceptable.Companion appliance spacing should also
be considered.
3"
(76 mm)
3"
(76 mm)
48 in.2 min.
(310 cm
24 in.2 min.
(155 cm2)
W10558994
2
)
01/2013
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When
acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger
tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed
within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
ELECTRICAL REQUIREMENTS
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit
are recommended.
WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and
turns.
■ When using elbows or making turns, allow as much
room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied
in Vent System Chart. Exhaust systems longer than those
specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
Vent System Chart
Number of
90° elbows
0
1
2
3
4
NOTE: Bottom exhaust installations have a 90º turn inside the
dryer. To determine maximum exhaust length, add one 90º turn
to the chart.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.