www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
30" Undercounter or Wall Ovens:
MEW5530BAB and MEW5530BAW
• Dimensions (Actual Size) •
Cutout width:
Cutout height:
Minimum cabinet width:
Minimum cabinet depth:
Recommended cutout location from floor :
28 3/16"
27 7/16"
30"
24"
4" - 33"
Distance from face of cabinet to
outer edge of open door (Door swing):
20 1/2"
Distance from face of cabinet to
front of closed door handle:
Overall unit width:
Overall unit height:
Penetration into cabinet:
15/16"
29 3/4"
27 3/4"
23 1/2"
Oven overlap distances when using
cutout dimensions listed above:
Top overlap:
Bottom overlap:
Right side overlap:
see below
0"
23/32"
Left side overlap: 23/32"
• Additional Information •
• Approved for undercounter installation.
• The unit does NOT overlap the top of the opening.
There is a trim piece that covers the top edge of the
cutout a very small amount (less than 1/16").
• Do Not block air intake slots along bottom of oven.
• IMPORTANT: nylon grip nuts that hold crate bottom
must be removed before installation.
• A three-wire, single phase, A.C. 120/208-240 volt,
60Hz cycle electrical system protected by a 30 amp
fuse or comparable circuit breaker must be provided .
7/8" O.D. flexible cable 4 feet long is furnished by
manufacturer. Mount junction box in area under
plywood floor if adequate lower cabinet space is
available. Locate 1 1/4" conduit access hole in the
back right hand side of the plywood floor.
Cabinet Opening
(not to scale)
Electrical box
30"
28 3/16"
24"
27 7/16"
4" - 33"
Overall Dimensions
(not to scale)
27 3/4"
SEE PAGE 2 FOR UNDERCOUNTER INSTALLATION
23 1/2"
29 3/4"
15/16"
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
214
BN372 • A214B149 • • 032603 • 95655 • 41793
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
•A complete floor is recommended to prevent unusual drafts and
capable of supporting 142 lbs.
• Minimum distance from bottom of opening to any object protruding
from cabinet face (i.e. cabinet door) directly below: 1" (because it is
an air flow area)
• If you are stacking two units: Maximum distance from floor to bottom
of lower oven opening is 7 1/2". Minimum distance from top of lower
oven opening to bottom of upper oven opening is 3/4".
• House wire to enter junction box at left side. Range wires to enter
right side of junction box.
• IMPORTANT : CANADA INSTALLATIONS ONLY - Breaker box
provided with oven must be located in an adjacent accessible location
on either side of oven (undercounter) or below (wall mount).
• See below for undercounter installation.
Page 2
This Data Sheet Includes Information On
Maytag
• Product Model Number (s): •
30" Undercounter or Wall Ovens:
MEW5530BAB and MEW5530BAW
• When installing 2 units side-by-side, the openings must be
separated a minimum of 6". Each unit must have its own electrical
box located on the wall of the opening.
Gas connection for cooktop must be
located in adjacent left accessible location
25" normal counter top depth
Minimum distance from the
top of the counter top when
installing a Maytag Gas
cooktop above: 32". Gas
and electrical connections for
the cooktop must be located
in left adjacent accessible
location. For cooktop
dimensions please request
the proper data sheet.
Minimum distance from the top of
the counter top when installing a
Maytag electric cooktop above:
29 11/16". For cooktop
dimensions please request the
proper data sheet.
27 7/16"
Cabinet (under counter) Opening
(not to scale)
1 1/4" Conduit access hole
23 1/2"
1 1/2" countertop
Bottom should support 142 lbs.
28 3/16"
24"
36" countertop height reccomended
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
BN372 • A214B149 • • 032603 • 95655 • 41793
149