Maytag MEDX5SPAW Dimension Guide

PRODUCT MODEL NUMBERS
3"*
MEDX5SPA
Dryer Dimensions
23¾"
(603 mm)
43"
(1092 mm)
43"
(1092 mm)
Electric Dryer
13¾"
(349 mm)
*291/2"
(749 mm)
27"
(687 mm)
A
A. Large opening side-swing door B. Wide opening hamper door
Minimum Required Spacing
18"* (457 mm)
1" (25 mm)
27"
(686 mm)
1" (25 mm)
A
A. Recessed area B. Side view – closet or conned area C. Closet door with vents
1"* (25 mm)
29
(743 mm)
*291/2"
(749 mm)
14" max.* (356 mm)
5½"*
¼"
(140 mm)
B
2
48 in.
*
(310 cm )
2
24 in.
(155 cm )
27"
(687 mm)
clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
B
(76 mm)
2
*
2
3"*
(76 mm)
*Additional spacing recommended
C
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
Minimum spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.
■ Additional spacing should be considered for ease of installation and servicing.
■ Additional clearances might be required for wall, door, and oor moldings.
■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise
transfer.
■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the
door are required. Louvered doors with equivalent ventilation openings are acceptable. Companion appliance
spacing should also be considered.
W10486882A
09/2012
ELECTRICAL REQUIREMENTS
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
The Vent System Chart provides venting requirements that will help achieve best drying performance.
Whirlpool Vent System Chart
Exhaust hoods:
Recommended Styles:
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Number of 90° elbows
0
1
2
3
4
NOTE: Side and bottom exhaust installations have a 90º turn
inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Determine vent length and elbows needed for best drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied in Vent System Chart. Exhaust systems longer than those specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Loading...