Maytag MEDP475EW Dimension Guide

PRODUCT MODEL NUMBERS
13
"
A
C
3"*
MEDP475E
Electric Dryer
18"* (457 mm)
Front view:
27"
(686 mm)
43"
(1092 mm)
11/2"
(38 mm)
Minimum Required Spacing:
14" max.* (356 mm)
48 in.
(310 cm )
2
*
2
Side view:
Wide opening side-swing door
223/4"
(578 mm)
291/2"
(749 mm)
Wide opening hamper door
(349 mm)
Side view:
3
/4
291/2"
(749 mm)
*Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
(76 mm)
2
*
24 in.
2
(155 cm )
1" (25 mm)
27"
(686 mm)
1"
1"*
(25 mm)
(25 mm)
29
½
(749 mm)
B
"
5½"*
(140 mm)
Installation spacing for recessed area or closet installation
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door, floor
moldings, and dryer venting.
■ Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. Companion appliance spacing should also be considered.
3"*
(76 mm)
W10755020A
06/2015
ELECTRICAL REQUIREMENTS
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
The Vent System Chart provides venting requirements that will help achieve best drying performance.
Vent System Chart
Exhaust hoods:
Recommended Styles:
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Number of 90° elbows
0
1
2
3
4
NOTE: Bottom exhaust installations have a 90º turn inside the
dryer. To determine maximum exhaust length, add one 90º turn to the chart.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Determine vent length and elbows needed for best drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in Vent System Chart. Exhaust systems longer than those specified will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times and
increased energy usage.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice.