ELECTRIC DRYER INSTALLATION INSTRUCTIONS
U.S.A. ONLY
Para una versi6n de estas instrucciones en espa_ol, visite www.Whirlpool.com
TABLE OF CONTENTS
DRYER SAFETY .............................................................................. 1
INSTALLATION REQUIREMENTS ................................................ 2
Tools and Parts ............................................................................ 2
Optional Equipment ..................................................................... 3
Location Requirements ................................................................ 3
ELECTRIC DRYER POWER HOOKUP ......................................... 5
Electrical Requirements ............................................................... 5
Electrical Connection ................................................................... 6
VENTING ....................................................................................... 11
Venting Requirements ................................................................ 11
Plan Vent System ....................................................................... 12
Install Vent System ..................................................................... 13
INSTALL LEVELING LEGS ........................................................... 13
CONNECT VENT ........................................................................... 14
CONNECT INLET HOSE
(STEAM MODELS) ........................................................................ 14
LEVEL DRYER .............................................................................. 15
COMPLETE INSTALLATION ....................................................... 15
TROU BLESHOOTING .................................................................. 15
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediatel_
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
W10255468C
W10259190B - SP
WARNING - "Risk of Fire"
- Clothes dryer installation must be performed by a qualified installer.
- Install the clothes dryer according to the manufacturer's instructions and local codes.
- Do not install a clothes dryer with flexibJe plastic venting materials, if fle×ible metal
(foiJ type) duct is instaJled, it must be of a specific type identified by the appliance
manufacturer as suitable for use with clothes dryers. Fle×ible venting materials are
known to collapse, be easily crushed, and trap lint. These conditions will obstruct
clothes dryer airflow and increase the risk of fire.
- To reduce the risk of severe injury or death, follow all installation instructions.
- Save these instructions.
State of California Proposition 65 Warnings:
WARNING: This product contains a chemical known to the State of California to cause cancer.
WARNING: This product contains a chemical known to the State of California to cause birth defects or other reproductive harm.
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read
and follow the instructions provided with any tools listed here.
• Flat-blade screwdriver • Caulking gun and compound
(for installing new exhaust
• #2 Phillips screwdriver vent)
• Adjustable wrench that
opens to 1" (25 mm) or • Tin snips (new vent
hex-head socket wrench installations)
(for adjusting dryer feet) • 1¼,,nut driver
• Level (recommended)
• Wire stripper (direct wire • Tape measure
installations) • Pliers
• Vent clamps
Parts supplied
Non-SteamModels
4 Leveling legs
Remove parts package from dryer drum. Check that all parts are
included.
NOTE: Do not use leveling legs supplied with dryer if installing
on a pedestal.
Steam Models
A B
A.Levelinglegs(4)
B."Y" connector
C.Shortinlet hose
Remove parts package from dryer drum. Check that all parts are
included.
NOTE: Do not use leveling legs supplied with dryer if installing
on a pedestal.
Parts needed
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements" before
purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please refer to the "Assistance
or Service" section in your Use and Care Guide.
C D
D. Long inlet hose
E. Rubber washer
E
2
Optional Equipment
Refer to your Use and Care guide for informationabout the
accessories available for your dryer.
Location Requirements
Explosion Hazard
Keep flammable materia(s and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
• A location that allows for proper exhaust installation.See
"Venting Requirements."
• Aseparate 30-amp circuit.
• If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (610 mm) of either side of the dryer.
See "Electrical Requirements."
• A sturdy floor to support the total dryer weight of 200 Ibs
(90.7 kg). The combined weight of a companion appliance
should also be considered.
A level floor with a maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer
Feet Kit, Part Number 279810. Clothes may not tumble properly
and automatic sensor cycles may not operate correctly if dryer is
not level.
• For a garage installation,you will need to place the dryer at least
18" (460 mm) above the floor. If using a pedestal, you will need
18" (460 mm) to the bottom of the dryer.
• Steam models only: Cold water faucets located within 4 ft
(1.2 m) of the dryer, and water pressure of 20-100 psi
(137.9-689.6 kPa). You may use the cold water supply from
your washer using the "Y" connector provided.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic sensor cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
A
Steam Non-Steam
(Electric or Gas) (Electric or Gas)
A 38" (965 mm) 38" (965 mm)
B 32 9/16"(827 mm) 31 lh" (800 mm)
C 27" (686 mm) 27" (686 mm)
D 52 9/16"(1335 mm) 51 W" (1308 mm)
NOTE: Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow.
Venting Dimensions
c
A*
Back View
Steam Non-steam
(Electric or Gas) (Electric or Gas)
A* 1" (25 mm) 1" (25 mm)
B 14" (356 mm) 14" (356 mm)
C 3 7/16"(87 mm) 3 7/16"(87 mm)
* Dimension A is approximate, depending on when the diamond
marking on the leveling foot is no longer visible.
Closet installation - Dryer only
Ill ,
"i-_, 114' max. -,,e.----
[_ _ 48"2*
I 18"min,*
(460ram)
C
(310cm2)_
24"2"(155Cm2) -
A*
Side View
Steam Non-Steam
(Electric or Gas) (Electric or Gas)
A* 1" (25 mm) 1" (25 mm)
B 7 5/8"(194 mm) 7 5/8"(194 mm)
C 3 3/8"(86 mm) 3 3/s"(86 mm)
* Dimension A is approximate, depending on when the diamond
marking on the leveling foot is no longer visible.
See "Venting Requirements."
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer.
This dryer has been tested for spacing of 0" (0 mm) clearance on the
sides and rear.Recommended spacing should be considered for the
following reasons:
• Additional spacing should be considered for ease of installation
and servicing.
• Additional clearances might be required for wall, door, and floor
moldings.
• Additional spacing should be considered on all sides of the dryer
to reduce noise transfer.
For closet installation,with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
• Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
L_J
-_4A*_,- B -_qO**_,--
Sideview
Steam Non-Steam
(Electric or Gas) (Electric or Gas)
A* 1" (25 mm) 1" (25 mm)
B 32 9/16"(827 mm) 31 lh" (800 mm)
C** 5" (127 mm) 5" (127 mm)
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed.
Recessed or closet installation - Dryer on pedestal
B--4
Steam Non-steam
(Electric or Gas) (Electric or Gas)
A 1" (25 mm) 1" (25 mm)
B 27" (686 mm) 27" (686 mm)
C 1" (25 mm) 1" (25 mm)
D* 1" (25 mm) 1" (25 mm)
E 32 9/16"(827 mm) 31 1/2"(800 mm)
F** 5" (127 mm) 5" (127 mm)
Closet door with vents
,_ 18"min.*
D*l E--4
F _
Steam Non-Steam
(Electric or Gas) (Electric or Gas)
A 0" (0 mm) 0" (0 mm)
B 38" (965 mm) 38" (965 mm)
C* 1" (25 mm) 1" (25 mm)
D 27" (686 mm) 27" (686 mm)
E* 1" (25 mm) 1" (25 mm)
*Required spacing
NOTE: Some models are not recommended for undercounter
installation.
4
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed
NOTE: Some models are not recommended for recessed or closet
installation.
Recommended installation spacing for cabinet
installation
NOTE: Some models are not recommended for cabinet installation.
• For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.
(Electric or Gas) (Electric or Gas)
A* 7" (178 mm) 7" (178 mm)
B* 7" (178 mm) 7" (178 mm)
C* 9" (229 mm) 9" (229 mm)
D** 5" (127 mm) 5" (127 mm)
E 32 9/16"(827 mm) 31 1/2" (800 mm)
F* 1" (25 mm) 1" (25 mm)
G 1" (25 mm) 1" (25 mm)
H 27" (686 mm) 27" (686 mm)
I 1" (25 mm) 1" (25 mm)
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed.
6"* (_52 mm)
( 976
1" --_ _ 27"=}_
(25 mm) 686 mm (25mm)
Steam Non-steam
(Electric or Gas) (Electric or Gas)
A* 5 1/2"(140 mm) 5" (127 mm)
*Required spacing
NOTE: Some models are not recommended for stacked recessed or
closet installation.
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD Part 280) or
Standard CAN/CSA-Z240 MH.
Mobile home installations require:
All Dryers:
• Metal exhaust system hardware, which is available for purchase
from your dealer.
• Special provisions must be made in mobile homes to introduce
outside air into the dryer. The opening (such as a nearby
window) should be at least twice as large as the dryer exhaust
opening.
ELECTRIC DRYER POWER
HOOKUP
Recommended installation spacing for recessed or
closet installation, with stacked washer and dryer
The dimensions shown are for the recommended spacing.
48 in. 2 *
(310 cm 2)
t_
3"* (76 ram)
T
0
24 in? * +
(155cm2)
1"*(25 ram)
Electrical Requirements
It is your responsibility
• Tocontact a qualified electrical installer.
• To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-
latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved in
remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.