Maytag MEDB200V, MEDB400V, MEDB700V, MEDB800V, MEDB850W Dimension Guide

Electric Dryer
30"
(762 mm)
221/4"
(565 mm)
43
1
/2"
(783 mm)
28"
(711 mm)
29"
(737 mm)
1"
(25 mm)
1"
(25 mm)
18"*
(457 mm)
14" max.* (356 mm)
5"
(127 mm)
1"
(25 mm)
30"
(762 mm)
14" max.* (356 mm)
5"
(127 mm)
1"
(25 mm)
28"
(711 mm)
3"*
(76 mm)
3"*
(76 mm)
48" 2*
(310 cm2)
24"
2
*
(155 cm2)
PRODUCT MODEL NUMBERS
MEDB200V, MEDB400V, MEDB700V, MEDB800V, MEDB850W
Electrical: This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time­delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Recommended Styles:
Louvered Hood
Acceptable Style:
Box Hood
OVERALL DIMENSIONS
Dryer dimensions
Dryer with extended back:
NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested spacing of 0" (0 mm) clearance on sides and rear.
Dryer with at back:
Angled Hood
The Vent system chart provides venting requirements that will help achieve best drying performance.
NOTE: Bottom exhaust installations have a 90° turn
Recessed area Side view - closet or conned area
(Dryer with extended back) inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Number of 90° elbows
0
1
2
3
4
Vent system chart
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
hoods
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Side view - closet or conned area
Closet door with vents
(Dryer with at back)
Do not use vent runs longer than specied in vent length chart.
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
Use the fewest 90° turns possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
* Required spacing
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable.
Ref. W10347663
02/2011