www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
|
This Data Sheet Includes Information On |
|
|
Side View |
|
|
Maytag |
|
23 1/2" |
1 13/16" |
|
|
|
(not to scale) |
|||
• |
Product Model Number (s): |
• |
|
||
|
|
||||
|
24" Dishwashers: |
|
|
|
|
|
DWU9962AAB, DWU9962AAE, DWU9962AAM, |
|
|
|
|
|
DWU9922AAB, DWU9922AAE and DWU9922AAM |
|
|
|
|
• |
Dimensions (Actual Size) |
• |
|
35 1/4" Maximum |
|
|
Height at full leg adjustment: |
35 1/4" Maximum |
|
|
|
|
|
1 1/2" |
33 3/4" Minimum |
||
|
Height at 0" leg adjustment: |
33 3/4" Minimum |
|
||
|
|
|
|||
|
|
|
|
||
|
Width: |
23 7/8" |
|
|
|
|
Depth: |
23 1/2" |
|
|
|
Door thickness incl. control panel: |
1 13/16" |
|
|
|
|
|
Door thickness: |
1 1/2" |
|
|
|
|
Depth with door open: |
48 1/2" |
|
|
|
|
Vertical toe space: |
3" to 4 1/4" |
|
48 1/2" |
|
|
Custom panel flange depth: |
1/4" |
|
|
|
Custom panel flange width: 5/16"
• |
Additional Information |
• |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
23 7/8" |
|
|
|
|
|
|
|
|
|
|
|
|||||||
DRAIN: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
• 32" Drain loop, 1/2" minimum I.D. Floor drains require |
|
|
Front View |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
a siphon break. |
|
|
(not to scale) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
• Drain hose extension kit available 904024. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• |
When draining into a disposer, make sure disposer |
|
|
|
|
|
|
|
|
|
|
|
1/4" Panel Size: |
|
|
|
|
|
|
|
|
|
|
|||||
drain plug is removed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1/4" Panel Size: |
|
|||||
WATER SUPPLY: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
35 1/4" Maximum |
|
|
|
|
23 9/16" wide |
|
|
|
|
|
|
|
|
|
|
||||||||||
• 15 to 120 psi water pressure. 120°F to 140° hot water |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
23 11/16" wide |
|
|||||||||||
supply recommended. |
|
|
|
33 3/4" Minimum |
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
18 3/16" high |
|
|
|
|
|
|
|
|
X |
|
|||||||||||
• |
Access for manual shut-off valve recommended. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 5/8" high |
|
|||||
• 3/8" compression to 3/8" male NPT fitting for water |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
valve. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
• Suggested water line size 3/8" O.D. copper or |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
equivalent. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
ELECTRICAL SUPPLY: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3" to 4 1/4" |
||||
• 120 volts, 60 Hz protected by a GROUNDED 15 amp |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
fuse or comparable circuit breaker. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Max amperage draw 12.0 amps. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Minimum wire size 14 gauge (No. 12 wire preferred) - |
|
|
Rough-in Information |
|
|
Copper only. Check all local codes. |
|
Plumbing and |
|
(Not to Scale) |
|
• Individual branch circuit serving only dishwasher |
|
electrical service |
|
Preferred |
|
recommended. |
|
must enter inside |
|
Drain Area |
|
• Electrical and water supplies should enter cabinet |
|
shaded area |
|
Wall area |
|
opening on the floor, or through the side walls as shown |
|
|
|
||
|
|
must be free |
|
||
in shaded areas of drawing |
|
3" |
|
3" |
|
|
|
of pipes and |
|||
• IMPORTANT: ALWAYS CHECK LOCAL AND NATIONAL |
|
|
|
wires |
|
|
Preferred |
|
|
|
|
CODES FOR FULL COMPLIANCE |
|
|
|
|
|
|
|
Drain Area |
|
|
|
See page 2 for additional information |
|
24" Minimum |
|
|
7" from floor |
|
|
34" - 35" |
|
8" |
5" from |
Subject to change without notice. This system is designed to |
|
underside of |
|
5" |
|
be updated daily if necessary. Dimension Express is not |
|
countertop |
|
back wall |
|
responsible for use of superseded, voided, or outdated data |
|
to floor |
3" |
|
|
sheets. Because of the difficulty or impracticability of deter- |
|
|
|||
mining actual damages, liability of Dimension Express shall |
|
|
|
24" Minimum |
|
not exceed $50.00. |
307 |
|
|
|
|
Copyright © Dimension Express, 2000. |
|
|
|
|
• NEVER reuse Data Sheets. Data Sheets are subject to change without |
• Call Dimension Express if you have any questions at (775) 833-3633 • |
notice. Dimension Express is a FREE service bureau and is updated daily, |
• Always refer to a current Code at a Glance or manufacturer directory • |
it makes far more sense to spend the time necessary to request new Data |
• Data Sheet codes change on the first of odd numbered months at 12:01am • |
Sheets for each project, as opposed to the problems, time, costs, and risks |
BN177 • A307B276 • 27754 • 002906 • 232421 • 41860 |
associated with reusing old Data Sheets. |
www.dexpress.com |
|
|
|
|
|
This Data Sheet Includes Information On |
|
|
|
|
DIMENSION EXPRESS |
|
|
|
|
|
Maytag |
|
|
|
|
Page 2 |
|
|
• |
Product Model Number (s): |
• |
|
|
|||
|
|
|
|
|
|
|||||
Fax on Demand (775) 833-3600 |
|
|
|
24" Dishwashers: |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
DWU9962AAB, DWU9962AAE, DWU9962AAM, |
|
|
|
|
|
|
|
|
|
|
DWU9922AAB, DWU9922AAE and DWU9922AAM |
|
|
|
|
Additional Information: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
TIPS: |
|
• DWU9962AAE and DWU9922AAE: Monochromatic White. |
|
|
|
|
||||
• Keep back free of drain, water and electrical supply. |
|
• DWU9962AAB and DWU9922AAB : Black. |
|
|
|
|
||||
• Connections preferably located toward left side of dishwasher. Care |
• DWU9962AAM and DWU9922AAM : Monochromatic Almond. |
|
|
|
|
|||||
should be taken to route pluming and electrical away from motor and |
|
|
|
|
|
|
|
|
|
|
blower. |
|
|
|
|
|
|
|
|
|
|
•When installing the dishwasher in or near a corner, allow enough room for the door to open without interfacing with any cabinet drawers of hardware.
•Dishwasher side panel kits are available: 904025 White, 904025L Almond and 904025P Primer.
•IMPORTANT: ALWAYS CHECK LOCAL AND NATIONAL CODES FOR FULL
COMPLIANCE
Custom Raised Panel Sizes
1/8" |
1/8" |
1/4"
Upper Panel |
|
18 3/16" |
|
|
|
1"
|
|
|
|
|
|
|
|
|
|
|
Shaded area |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
23 9/16" |
|
|
|
1/8" |
|
|
|
|
|
can only be 3/8" |
|||||
|
|
|
|
|
thick max.!! |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3/16" |
|
|
|
|
23 11/16" |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lower Panel |
|
|
|
|
4 5/8" |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3/16" |
|
|
|
|
|
|
3/16" |
3/16" |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(not to scale)
Trim Kit DAX1000AXX is required for the procedure.
Raised door panels, typically Wood, have a maximum thickness of 3/8" along the lower 1" of door panel as shown in the shaded portion of drawing. This is done to prevent the panel from contacting with the access panel when dishwasher door is opened.
Thick wood panels should be 1/4" thick. For panels more than 1/4" thick, the outer edge will need to be routered as shown in drawing.
When applying a 3/4" raised panel to 1/4" backing, there must be a 5/16" clearance on side of 1/4" backing. This clearance allows the panel to slide into the flange.
Wood panels need a waterproof protective finish applied to all sides and edges of panels.
Maximum panel weight is 11 1/2 pounds with booster spring (Provided with the DAX1000AXX).
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright © Dimension Express, 2000.
276
• NEVER reuse Data Sheets. Data Sheets are subject to change without |
• Call Dimension Express if you have any questions at (775) 833-3633 • |
notice. Dimension Express is a FREE service bureau and is updated daily, |
• Always refer to a current Code at a Glance or manufacturer directory • |
it makes far more sense to spend the time necessary to request new Data |
• Data Sheet codes change on the first of odd numbered months at 12:01am • |
Sheets for each project, as opposed to the problems, time, costs, and risks |
BN177 • A307B276 • 27754 • 002906 • 232421 • 41860 |
associated with reusing old Data Sheets. |