Maytag 714619, 714622 User Manual

Dryer Dimensions
Gas and Electric Dryer
PRODUCT MODEL NUMBERS
MEDB755D, MGDB755D
Front View
29"
(737 mm)
407/8"
(1038 mm)
1
/2"
(13 mm)
NOTE: Leveling legs should be 1/2" (13 mm).
Back View
4"
(101 mm)
Side View
503/4"
(1289 mm)
A. Wide opening side-swing door B. Wide opening hamper door
Installation Spacing
14" max
(356 mm)
42"
(1067 mm)
281/4"
(717 mm)
281/4"
(717 mm)
A B
301/4"
(768 mm)
43/4"
(121 mm)
141/2"
(368 mm)
91/4"
(235 mm)
1
/4"
1
(32 mm)
43/4"
(121 mm)
141/2"
(368 mm)
(235 mm)
91/4"
1
/4"
1
(32 mm)
Steam Non-Steam
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door,
and oor moldings.
■ Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■ Companion appliance spacing should also be considered.
6"/0"
(152 mm/
0 mm)
1"/0"
(25 mm/0 mm)
(25 mm/25 mm)
Recommended/Minimum spacing
18"/18"
(457 mm/
457 mm)
1"/1"
3"/3"
(76 mm/
76mm)
3"/3"
(76 mm/
76mm)
2
2
/48"
48"
2/
(310 cm 310 cm2)
2/
2
24"
24"
2/
(155 cm
155 cm2)
W10680136C
01/2015
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
ELECTRICAL REQUIREMENTS - Gas models only
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended.
ELECTRICAL REQUIREMENTS - Electric models only
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specied
on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and
turns.
■ When using elbows or making turns, allow as much
room as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied in Vent System Chart. Exhaust systems longer than those specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
The “Vent System Chart” provides venting requirements that will help achieve best drying performance.
Vent System Chart
Number of
90° turns
or elbows
0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m)
1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)
2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m)
3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m)
4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m)
NOTE: Bottom exhaust installations have a 90° turn inside the
dryer. To determine maximum exhaust length, add one 90° turn to the charts.
Type
of vent
Box/louvered
hoods
Angled
hoods
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.