Maxx Cold MXCR50B, MXCR65B Instructions Manual

BOTTLE COOLER
Service, Installation and Care Manual
Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components immediately. See page 2.
READ BEFORE USE
PLEASE SAVE THESE INSTRUCTIONS!
Service and Installation Manual
2
CONTENTS
SPECIFICATIONS…………………………………………………….……………………….………2 CONGRATULATIONS ON YOUR NEW COOLER…………………………………….………2 INSTALLATION………………………………………………………………………….…………..….2
ELECTRICAL CONNECTION………………………………………………………………………….3
OPERATION INSTRUCTIONS………………………………………………………………..……………3
STORAGE OF FOOD STUFFS..………………………………………………………………………3
DEFROSTING THE CABINET…………………………………………………………………………3 MAINTENANCE……………………………………………………………………….……………….3 TROUBLE SHOOTING……………………………………………………………………………………….4 DISPOSAL……………………………………………………………………………………………………4 SPECIAL PIONTS TO NOTE………………………………………………………………………………4
WIRING DIAGRAM…………………………………………………………………………………5
SPECIFICATION
MODEL#
V/Hz/Ph
AMPS
STORAGE CAPACITY
Cu-ft
HP
BTU
CHARGE
OZ
SHIP
WEIGHT
LBS
NEMA PLUG
MXCR50B
115/60/1
7
15
1/2
3200
10.58
310
5-15P
MXCR65B
115/60/1
7
20
1/2
5400
12.34
353
5-15P
CONGRATULATIONS ON YOUR NEW COOLER
Note these instructions apply to all coolers. Installations of equipment may not exactly correspond to your model.
INSTALLATION
Make sure that the cooler is not damaged on arrival. Your supplier must be notified of any transport damage, within 24 hours of delivery.
The cooler should be placed in a warm, dry room, with suitable ventilation. Place the cooler in such a way, as to allow the free circulation of air around it. That is, with at least 100mm
space all around it. Never place the cooler in strong sunlight. The cooler be placed on a level surface. Make sure that it does not
rock. If the cooler has been stored or transported cold, it must not be started before the compressor is judged to
have reached a temperature at least+5. It is recommended to clean up the cooler before starting it.
Service and Installation Manual
3
ELECTRICAL CONNECTION
The cooler must be connected to a socket with the correct voltage/frequency, as show on the nameplate. The standard for u.s is 115V/50HZ. Voltage variations of ±10% are acceptable. Greater variations can damage the cooler, and in such cases the factory warranty is not valid. In the case of extreme voltage variation, above or below the standard, your local supplier will be able to advise you, what to do.
The cooler requires extra protection according to the Danish Heavy Current Regulations. This also applies, if a new cooler is replaced, which did not have such protection. The purpose of extra
protection, is to protect the user from dangerous electric shocks, in the case of defect.
OPERATION INSTRUCTIONS
The temperature in the cooler is automatically regulated by a pre adjusted thermostat. The position of the cooler, the ambient temperature, the number of times the lid is opened and for how long
the lid is opened, all these factors affect the temperature in the cooler, which should therefore not be placed in sunlight or closed to a heat-radiating surface.
If your cooler is fitted with a lock, the key should be kept out of the reach of children. If your new cooler is to replace an older one, which is not in use any more, you should remove the lock mechanism, on the old one, before disposing it.
STORAGE OFF FOOD STUFFS
The cooler is only designed as a conserver, and is the not suited to cold freeze foodstuffs. In other words, only refrozen food must be placed in the cooler. Next to that the cooler must not be filled beyond the height limit of the contents line, or in cases where there is no such line, to within 100mm below the lid. This is to ensure the product temperature less than+2.
DEFROSTING THE CABINET
In the course of time, a frost layer will be naturally formed within the cooler. When this layer is 5-8mm thick, the cabinet should be defrosted the following way:
remove the plug from the socket; open the lid and leave it open; loosen the frost layer using a plastic or wooden scraper.
The defrosting process can be speeded up by using bowls of hot water.
Never use sharp or pointed instruments
After final defrosting, the cabinet should be cleaned as described in section: Maintenance. the cabinet should be thoroughly dried after cleaning.
MAINTENANCE
This cooler can be cleaned using warm water and a mild detergent. Rinse with clean water to finish off.
Never use detergents that contain chlorine.
The lid may be cleaned in the same way as the cooler.
Loading...