MAXON Series LV AIRFLO® burners are designed for heating process air in motion. An iron or aluminum bronze body which
serves as the gas manifold is drilled to discharge the fuel gas between diverging mixing plates.
The entire burner assembly is mounted inside a process air duct directly in the air stream being heated. The air stream passes
across the burner and through the mixing plates and is used as combustion air. Carefully controlled mixing plate aeration patterns
give progressive mixing, superior cross-ignition and flame retention across the entire burner assembly length. The Series LV
®
AIRFLO
burner burns clean and odor-free with low levels of NOx production.
Correctly sized process air ducts and the resulting duct static pressure drop across the burner are the keys to successful
operation.
Normal capacities vary widely with the application and the duct pressures. The fuel used and the design velocities will affect the
burner turndown. Modular design permits the burner shape and total heat release to match the application needs.
Performance data varies depending upon temperature of air upstream and downstream of the burner assembly, the percentage of
®
oxygen (by volume) in the passing air stream, and the allowable duct static pressure drop across the Series LV AIRFLO
Several varieties of Series LV AIRFLO® burners are offered. Each type is optimized for a specific type of application. All varieties
can be used as raw gas type systems or partial air/gas premixture for applications where higher upstream temperatures and/or
lower oxygen levels are involved.
®
LV-NP1 AIRFLO
burner system for fresh air heating with low heat release per lineal foot and outlet temperatures up to 540°C. For upstream process
air temperature up to 315°C.
LV-3G AIRFL O
for raw gas burner applications or those requiring a partial air/gas premixture system and/or outlet temperatures up to 540°C. For
upstream process air temperature up to 315°C.
LV-4D AIRFLO
up to 815°C. For upstream process air temperature up to 540°C.
LV-5D AIRFLO
930°C outlet temperature requirements. For upstream process air temperature up to 540°C.
LV-5B AIRFLO
up to 930°C outlet temperatures. For upstream process air temperature up to 565°C.
burner with its gray iron body and #321 stainless steel mixing plates is the most economical choice for a raw gas
®
burners have gray iron bodies and #321 stainless steel mixing plates. Four different versions are available, either
®
burners have a ductile iron body and #310 stainless steel mixing plates for applications with outlet temperatures
®
burners complement their ductile iron bodies with Hastelloy-X mixing plates for use in applications with up to
®
burners have an aluminum bronze body casting with Hastelloy-X mixing plates for use with applications requiring
Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel and gas quality.
Burner sizeLV-NP 1LV-3GLV-4DLV-5DLV-5B
Maximum capacity per foot [2] kW 175 730 730 730 730
Minimum capacity per foot [2] kW 9 22 22 22 22
Natural gas differential pressure [3] mbar 10 70 70 70 70
Flame length [4] m 0.3 2 2 2 2
Pressure drop process air [5] mbar 0.5 - 6.2
[1] sg (specific gravity) = relative density to air (density air = 1.293 kg/Nm3)
[2] Maximum and minimum capacities are highly dependent upon the application. Check “Specifications of LV AIRFLO burners” for more infor-
mation.
[3] Natural gas differential pressure at burner inlet at maximum stated burner capacity. The stated values are valid for burners with standard gas
drillings. Refer to “Specifications of LV AIRFLO burners” for gas differential pressures to be used with alternative gas drillings.
[4] Flame length at highest capacity and highest process air pressure drop across the burner when firing on fresh air. The flame length and
flame aspect are highly dependent upon factors such as process air velocity and process air oxygen content. Refer to “Specifications of LV
AIRFLO burners” for more information.
[5] Stated process air pressure drop across the burner should never exceed the specified range in this table. In some specific applications, the
process air pressure drop range could be even more narrow.
Series LV AIRFLO® burners are designed for stable, efficient, raw gas operations in air streams with relatively low duct velocities.
Duct static pressure drops may be as low as 0.5 mbar or up to 6.2 mbar.
®
Elevated air stream temperatures approaching the Series LV AIRFLO
as low as 12% (by volume) are tolerated without a need to add primary combustion air. For applications with low oxygen levels, a
partial premixture must be added through the system.
Typical applications include thermal incinerators, cogeneration, spray dryers, hot air generators with variable flows, rotating drum
dryers and calciners.
burner can be as high as 565° C. Reduced oxygen levels
1) LV AIRFLO® burner
2) Combustion chamber
3) Gas pipe train
4) MAXON shut-off valves
3500 kW hot air generator with 9 ft LV-4D AIRFLO® burner
MAXON Series LV AIRFLO® burners are especially designed to meet the high demands of most of the local standards on air
quality of direct fired process air heating applications worldwide.
If correctly used within the performance limits as described on page 4-21.4-7, both CO and NOx will remain far below the limits as
determined in most standards.
Exact emissions performance may vary in your application. Contact MAXON for information on installation specific estimates or
guarantees. No guarantee of emissions is intended or implied without specific written guarantee from MAXON.
®
Read “Specifications of Series LV AIRFLO
burners” for complete information on these burner types.