09/03 MS2101
Temperature
Control Systems
SERIES14 DUAL TEMP DIALS*
Temperature control system.
70 |
75 |
65 |
80 |
60 |
85 |
55 |
90 |
C |
US |
TD114 55°-90°F Dial |
140 |
150 |
130 |
160 |
120 |
170 |
C |
US |
TD114 120°-170°F Dial |
System components:
A1014 or A1014L Amplifier
TD114 55°-90°F Dial*
TD114B 120°-170°F Dial*
TS214B* Dual Temp. Sensor
*Any two standard temp. ranges are available.
System utilizes two temperature ranges (Spray & Dry) using any two standard TD114 Series analog temperature dials. The TS214 temperature sensor consists of two tempera- ture-sensing elements - one for the Spray range and one for the Dry range. Switching between the two temperature range dials and sensors is accomplished by a DPDT Switch (not supplied).
SERIES14 DUAL TEMP DIALS with SWITCH*
Temperature control system with temperature range selection switch.
SPRAY |
|
DRY |
||
70 |
75 |
|
140 |
150 |
65 |
|
80 |
|
|
|
|
|
130 |
160 |
60 |
|
85 |
|
|
55 |
|
90 |
120 |
170 |
|
|
|
||
C |
US |
|
C |
US |
TD214B*, 55°-90°F, 120°-170°F Dual Temperature Dial with Switch in 4 x 6 enclosure.
System components:
A1014 or A1014L Amplifier
TD214B* 55°-90°F, 120°-170°F Dual Temp. Dial with Switch in 4 x 6 enclosure
TS214B* Dual Temp. Sensor
*Any two standard temp. ranges are available.
System utilizes two temperature ranges (Spray & Dry) using any two TD114 Series analog temperature dials. The two temperature range dials are mounted in a 4 x 6 electrical box enclosure (or on the 4 x 6 cover plate only, designated by “X” suffix) with a DPDT switch mounted between them. The TS214 temperature sensor consists of two temperature-sens- ing elements - one for the Spray range and one for the Dry range. Switching between the two temperature range dials and sensors is accomplished by the DPDT supplied switch.
Booth Spray
PaintSprayBooth
Applications
P.O. Box 2230 Southfield, MI 48037-2230 U.S.A.
248.356.1400 www.maxitrol.com