Masterflex 77240-00, 77240-10 Instruction Manual

OPERATING MANUAL:
Compact Pumps
pages 1-8
MANUEL DE L’UTILISATEUR:
Entrainements de Pompes Compactes
pages F1-F8
BEDIENUNGSANLEITUNG:
seiten D1-D8
MANUAL DE OPERACIÓN:
Bombas Compactas
páginas E1-E8
MANUALE DI ISTRUZIONI:
Pompe Compatte
pagine T1-T8
77240-00 77240-10
Model No. Nº de modèle Modellnummern Modelo No. Modello No.
Cole-Parmer Instrument Co.
625 E. Bunker Court, Vernon Hills, Illinois U.S.A. 60061-1844 • 800-MASTERFLEX (627-8373) • (847) 247-2929 (fax) www.masterflex.com • e-mail: techinfo@coleparmer.com
Barnant Company
28W092 Commercial Ave., Barrington, Illinois U.S.A. 60010-2392 • (847) 381-7050 • (847) 381-7053 (fax) www.barnant.com • e-mail: barnant@barnant.com
A-1299-5092
Edition 01
TABLE OF CONTENTS
Title Page
SAFETY PRECAUTIONS........................................................2
GENERAL DESCRIPTION......................................................3
SETUP AND DRIVE OPERATION.......................................4-6
MAINTENANCE ......................................................................6
SPECIFICATIONS...................................................................7
WARRANTY ............................................................................7
PRODUCT RETURN...............................................................7
TECHNICAL ASSISTANCE.....................................................7
SAFETY PRECAUTIONS
WARNING: Tubing breakage may result in fluid being sprayed from pump. Use appropriate measures
to protect operator and equipment.
CAUTION: Tubing for use with the MASTERFLEX®L/S®compact pump are Masterflex®two-stop tube sets.
See Appendix A for specifics. Use of tubing other than that specified will result in poor pumping performance and/or pump system damage and voiding of applicable warranty.
WARNING: PRODUCT USE LIMITATION
These products are not designed for, nor intended for use in patient-connected applications, including, but not limited to, medical and dental use and, accordingly, have not been submitted for FDA approval.
2
Trademarks bearing the ® symbol in this publication are registered in the U.S. and in other countries.
3
GENERAL DESCRIPTION
The MASTERFLEX®L/S®Compact Pump System,
Figure 1,
is enclosed in
an epoxy-painted metal housing. The Pump System can accommodate
one or two tubes simultaneously (depending on model) at controlled speeds as low as 20 rpm. Tubing is held in place by stops bonded to the tubing and slots in the Tubing Retainer brackets. For a list of tube sets for use with the Pump System, refer to Appendix A.
The latching Occlusion Bed allows quick loading or changing of tubing. The Pump Head Rotor contains three rollers for optimum flow and positive flow checking. All units operate from an External DC Power Supply and are supplied with a Universal Power Supply (see Input Specification for operating voltage/frequency). This power supply provides a DC output for connection to the Pump Drive.
The single-turn, adjustable Speed Control, Figure 2, provides variable flow operation. The green PWR On indi­cator lights whenever the pump is oper­ating. The Power On/Direction Switch turns power on when either clockwise or counterclockwise pump rotor direction is selected. The MAX Button is used for priming and purging and operates the pump at maximum speed when depressed.
Occlusion Bed Latch
Universal Power Supply
Figure 1. Masterflex
®
L/S®Compact Pump System
Figure 2. Pump — Front Panel
Tubing Retainer Bracket
Tubing Retainer Bracket
PWR On Indicator
MAX: Press and hold to prime or purge pump
Speed Control: Provides variable flow adjustment
Power On/Direction Switch
Occlusion Bed Latch: Push to right to release occlusion bed for loading or changing tubing