Masterflex 07090-45, 07090-65 INSTRUCTION SHEET

Masterflex 07090-45, 07090-65 INSTRUCTION SHEET

Assembled by:

INSTRUCTION SHEET

PTFE CHECK VALVE INSTALLATION PROCEDURES

Two PTFE Check Valves are available with the following operating characteristics:

 

07090-45

07090-65

Flow rate (Max.)

7 L/min.

1.25 L/min.

Port Connection

1/4" NPT(M)

1/8" NPT(M)

Cracking pressure

< 1 psig

< 1 psig

Max. pressure @ inlet

75 psig

75 psig

Max. differential pressure (across valve)

10 psig

20 psig

Flow coefficient, Cv

0.76

0.08

Max. reverse leakage

9 ml/min.

4 ml/min.

(@ rated pressure)

 

 

Note that a small arrow on the valve body indicates the direction of flow. Both valves are made with all PTFE parts, except that the 07090-65 Valve uses a borosilicate glass check ball.

Installing your PTFE check valves requires some care regarding the handling of PTFE threads and the application of these valves:

1.When connecting piping to valves, use an open end wrench on the outer flats of the valve to prevent rotation of the valve halves or the valve assembly.

2.Tighten the female threaded fitting onto the valves using 7 in.-lb. (medium hand-tighten) of torque.

3.A pressure relief valve should be used to limit the system pressures to maximums indicated. Consult you distributor for specific recommendations.

4.Before placing valves into service, test the plumbing system with an inert fluid under anticipated operating pressure.

5.Some finite back flow leakage will be experienced with these valves, therefore they are not recommended for use in an application where a positive shut-off is required.

Trademarks bearing the ® symbol in this publication are registered in the U.S. and in other countries.

Page 1 of 1

 

A-1299-0310

Printed in U.S.A.

Edition 07

 

 

 

Loading...