Master Bilt MPM-72 User Manual

Installation & Operations Manual
Master-Bilt Products
908 Highway 15 North
New Albany, MS 38652
1
PN 071-90000
Rev 03/06/08
2
TABLE OF CONTENTS
INTRODUCTION………………………………….……………………………………………………………………4 STORE CONDITIONS / LOCATION..………….…..………………………………………………………………..4 WARNING LABELS AND SAFETY INSTRUCTIONS………..…..……………………………………………… 5 PRE-INSTALLATION INSTRUCTIONS………………………..…..………………………………….…………… 6 Inspection for ShippingDamage……………………………………………………………….…………… 6 INSTALLATION INSTRUCTIONS………………………………………………………………………………….. 6
General Instructions…………………………………………………………………………………………. 6 Thermometer Installation…………………………………………………………………………………….6 Condensate Evaporator...……………………………………………………………………………………8 Power Toggle Switch…...…………………………………………………………………………………… 8 Electrical……..…………………………………………………………………………..…………………….8
STARTING PROCEDURE…………………………………………………………………………………………….8 FINAL CHECK LIST…………………………………………………………………………………….……………..8 LOADING………………………………………………………………………………………………………………..9 CLEANING……………………………………………………………………………………………………………...9 SERVICE INSTRUCTIONS (Trouble Shooting Guide)………………………….……………………………….9 MASTER-BILT PART NUMBERS……………………………………………………………………………………9 ACCESSORIES LIST………………………………………………………………………………………………….10 SALE AND DISPOSAL………………………………………………………………………………………………..11
WIRING DIAGRAMS………….…………………………………………………………….…………………….......12
3
INTRODUCTION
Thank you for purchasing a Master-Bilt cabinet. This manual contains important instructions for installing, using and servicing a Master-Bilt MPM/QMPM series open air case. Read all these documents carefully before installing or servicing your equipment. This manual should be left in the care of the store owner or manager.
STORE CONDITIONS / LOCATION
The Master-Bilt MPM/QMPM cases are designed to operate in the controlled environment of an air conditioned store. The store temperature should be at or below 75°F and a relative humidity of 55% or less. At higher temperature or humidity conditions, the performance of these cases may be affected and the capacity diminished. It is not uncommon in a newly constructed store for the temperature and humidity to be above design conditions. These excessive conditions may produce sweating in the case until the store is operational and the ambient environment is more desirable.
The Master-Bilt MPM/QMPM should not be positioned where it is directly exposed to rays of the sun or near a direct source of radiant heat or air flow. No HVAC return or supply air ducts may be located near case openings. This will adversely affect the case air flow and will result in poor performance. Do not open windows or doors that will affect the case air flow. The maximum air velocity near the case air return is 50 FPM. If this case is to be located against a wall there should be at least a 6” space between the wall and the back of the case. The cabinet also requires a clearance of 10” at the top. This space will allow for the circulation of air behind the case.
These cases should always be loaded properly. This unit will operate differently when loaded or unloaded. Consult the section of this manual that specifies loading procedures on page 6.
A P-trap is included with each case. It is important that each case has a P-trap installed. Check drain tubing to insure that it is traped and routed into the condensate pan.
NOTICE
Read this manual before installing your cabinet. Keep the manual and refer to it before doing any service on the equipment. Failure to do so could result in personal injury or damage to the cabinet.
DANGER
Improper or faulty hook-up of electrical components of the refrigeration units can result in severe injury or death.
All electrical wiring hook-ups must be done in accordance with all applicable local, regional or national standards.
NOTICE
Installation and service of the refrigeration and electrical components of the cabinet must be performed by a refrigeration mechanic and/or a licensed electrician.
4
The portion of this manual covering refrigeration and electrical components contains technical instructions intended only for persons qualified to perform refrigeration and electrical work. This manual cannot cover every installation, use or service situation. If you need additional information, call or write us:
Customer Service Department Master-Bilt Products 908 Highway 15 North New Albany, MS 38652 Phone: 800-684-8988 Fax: 866-882-7629
WARNING LABELS AND SAFETY INSTRUCTIONS
This symbol is the safety-alert symbol. When you see this symbol on your cabinet or in this manual, be alert to the potential for personal injury or damage to your equipment.
Be sure you understand all safety messages and always follow recommended precautions
and safe operating practices.
NOTICE TO EMPLOYERS
You must make sure that everyone who installs, uses or services your cabinet is thoroughly familiar with all safety information and procedures.
Important safety information is presented in this section and throughout this section and throughout the manual. The following signal words are used in the warnings and safety messages:
DANGER: Severe injury or death will WARNING: Severe injury or death can CAUTION: Minor injury or damage to your cabinet can occur if you ignore the message. NOTICE: This is important installation, operation or service information. If you ignore the
message, you may damage your cabinet.
The warning and safety labels shown throughout this manual are placed on your Master-Bilt Products cabinet at the factory. Follow all warning label instructions. If any warning or safety labels become lost or damaged, call your customer service department at (662) 534-9061 for replacements.
occur if you ignore the message.
occur if you ignore the message.
CAUTION!
GROUND REQUIRED
FOR SAFE OPERATION
This label is located on top of the electrical control This label is attached to the cabinet power cord label and on the wiring channel. on models with a power cord.