Master-Bilt BSG-48 User Manual

BSG-48, 74
Installation & Operations Manual
Master-Bilt Products
908 Highway 15 North
New Albany, MS 38652
Phone: (800) 684-8988
PN 075-90000
Rev 01-03-11
1
SOLLATEK CONTROLLER
2
TABLE OF CONTENTS
INTRODUCTION………………………………….……………………………………………………………………4 STORE CONDITIONS…………………………….……………….…..…………………………………………….. 4 WARNING LABELS AND SAFETY INSTRUCTIONS………..…..……………………………………………… 5 PRE-INSTALLATION INSTRUCTIONS………………………..…..………………………………….…………… 6 Inspection for Shipping Damage…………………………………………………………….…………… 6 INSTALLATION INSTRUCTIONS………………………………………………………………………………….. 6
General Instructions…………………………………………………………………………………………. 6 Mechanical ..…………………………………………………………………………………………………..6 Electrical…………...…………………………………………………………………………………………..7 Temperature Control…… ………………………….………………………………………………………..7
Leg……………………………………....……………………………………………………………………..7
Doors ..…………....…………………………………………………………………………………………...8
SERVICE INSTRUCTIONS …………………………………………………………………………………………8 TEMPERATURE CONTROL AND FAN MOTOR REPLACEMENT……………………………………………..9 FINAL CHECK LIST…………………………………………………………………………………….……………..9 MASTER-BILT PART NUMBERS ………………………………………………………………………………..10 ACCESSORIES …………………………………………………………………………………………………..10 SALE AND DISPOSAL ……………………………………………………………………………………………11 WIRING DIAGRAMS BMG/TMG...……………………………………….……..……………….……………...12-13
3
INTRODUCTION
Thank you for purchasing a Master-Bilt cabinet. This manual contains important instructions for installing, using, and servicing a Master-Bilt BSG case. A parts list is included with this manual. Read all these documents carefully before installing or servicing your equipment.
STORE CONDITIONS
The Master-Bilt BSG cases are designed to operate in the controlled environment of an air-conditioned store. The store temperature should be at or below 75°F and a relative humidity of 55% or less. At higher temperature or humidity conditions, the performance of these cases may be affected and the capacity diminished.
The Master-Bilt BSG should not be positioned where it is directly exposed to rays of sun or near a direct source of radiant heat or airflow. This will adversely affect the case and will result in poor performance.
If this case is to be located against a wall, there should be at least 4” space between the wall and the back of the case. This space will allow for the circulation of air behind the case, which will prevent condensation on the exterior surfaces.
NOTICE
Read this manual before installing your cabinet. Keep the manual and refer to it before
doing any service on the equipment. Failure to do so could result in personal injury or damage to the cabinet.
DANGER
Improper or faulty hook-up of electrical components on the refrigeration units can result in severe injury or death.
All electrical wiring hook-ups must be done in accordance with all applicable local, regional or national standards.
NOTICE
Installation and service of the refrigeration and electrical components of the cabinet must be performed by a refrigeration mechanic and/or a licensed electrician.
The portions of this manual covering refrigeration and electrical components contain technical instructions intended only for persons qualified to perform refrigeration and electrical work. This manual cannot cover every installation, use or service situation. If you need additional information, call or write us:
Customer Service Department Master-Bilt Products Highway 15 North New Albany, MS 38652 Phone (800) 684-8988 Fax (800) 684-8988
4