00-05 -3 91 3
08
11
1009
AC/ DC Volta ge Meas ureme nts
War nin gs
Obs erve al l safet y preca ution s when wo rking o n live
vol tages .
1.Pu t the fun ction s elect s witch t o audib le.
2.Touc h the tes t probe s acros s the cir cuit be ing
mea sured .
3.Th e teste r will tu rn on aut omati cally i f the vol tage
exc eeds 12 v olts.
4.Th e LEDs wi ll indi cate th e volta ge.
5.Fo r AC vo ltage , the “+” a nd “-” LE Ds will i llumi nate.
6.Fo r DC volt age, th e “+” LED w ill ill umina te if the
ins trume nt test p robe is t ouchi ng the po sitiv e side
of th e circu it. The “ -” LED wi ll illu minat e if the
ins trume nt test p robe is t ouchi ng the ne gativ e
sid e of the ci rcuit .
7.T he buzz er will r ing whe n the Volt age is hi gher
tha n about 5 0 volts .
Volt age LED s teps
Acc uracy
±12 ,24,5 0,120 ,230, 400V
-30 % to 0% of in dicat ion
Res ponse t ime
AC fr equen cy rang e
<0. 1s
50/ 60Hz
Ope ratio n time
30 se conds m aximu m
Rec overy t ime
10 mi nutes a fter
max imum op erati on
tim e has bee n reach ed
Tempe ratur e range
14℉ to 1 31℉(-10℃ t o 55℃)
Rel ative H umidi ty
80% m aximu m
Alt itude
700 0ft(2 000m)
saf ety
CAT III 4 00V
Wei ght
98. 5g
Dim ensio n
223 *40*3 2 mm
Spe cific ation s
Mai ntena nce
1.ke ep the te ster dr y. if it get s wet, wi pe it off.
2.us e and sto re the te ster in n ormal t emper ature s.
tem perat ure ext remes c an shor ten the l ife of th e
ele ctron ic part s and dis tort or m elt pla stic pa rts.
3.ha ndle th e teste r gentl y and car efull y. dropp ing
it ca n damag e the ele ctron ic part s or the ca se.
4.ke ep the te ster cl ean. wi pe the ca se occa siona lly
wit h a damp cl oth. do n ot use ch emica ls, cle aning
sol vents , or dete rgent s.
GFC I Test
War nin gs
Obs erve al l safe ty prec autio ns when wo rking on l ive
vol tages . The GF CI test fun ction ca n onl y be use d
on 120 vo lt AC recep tacle s with GFC I prot ectio n.
1.Ch eck the ins truct ions on the s pecif ic GFCI
devi ce you are tes ting be fore pro ceedi ng.
2.Pu t the fu nctio n sel ect swi tch to GFCI te st.
3.Pr ess the tes t but ton on the GFC I rec eptac le.
The GFC I sho uld trip . If not , do not us e the
rece ptacl e and co nsult a qua lifie d ele ctric ian.
If it does tr ip, pres s the rese t butt on on the
GFCI re cepta cle.
4.I nsert on e tes t pro be into hot si de of the outl et
bein g tes ted.
5.In sert the ot her test pr obe into t he groun d of
the out let bein g tes ted.
6.Th e tes ter shou ld indic ate 120VA C if the ou tlet
is powe red and wir ed prop erly.
7.Pr ess the GFC I tes t but ton.
8.Th e ind icato r lig hts shou ld turn off in dicat ing
the GFC I has tr ipped .
9.If th e GFC I doe s not tr ip,ei ther the re cepta cle
is mis- wired or th e GFCI is def ectiv e.Do not us e
the rec eptac le and cons ult a qual ified el ectri cian.
Not e
The t ester c annot t est GFC I opera tion on 2 -wir e
(no n-gr ounde d) outl ets.
DONG GUAN HU AYI MAST ECH COM PANY LIMI TED
Yulia ngwei I ndust rial Ar ea,Q ingxi
Dong guan, Gua ngdon g,Ch ina
http :// www .p- mast ech. com