Mastech MS8361D User Manual

Page 1
MS8361D
CAT III
Page 2
Contents
1. Saf ety s tan dar ds
1.1 FC C Sta tem ent
1.2 Us ing t he me ter
1.3 Sa fet y sta nda rds
1.4 Ma int ena nce
2.1 Pa rt na me
2.2 Bu tto ns/ I npu t jac k des cri pti on
2.3 Aut o pow er of f fun cti on
2.4 LC D Dis pla y
3. Tech nic al sp eci fic ations
3.1 Ge ner al sp eci fic ati ons
3.2 Tech nic al in dic ato rs
3.2. 1 Dc vo lta ge
3.2. 2 Ac vol tag e
3.2. 3 Res ist anc e
3.2. 4 Dio de te st
3.2. 5 Con tin uit y
3.2. 6 DC cu rre nt
3.2. 7 AC cur ren t
3.2. 8 hFE t ran sis tor g ain
3.2. 9 Cap act anc e
3.2. 10 Fr equ enc y
3.2. 10. 1 In V mo de
3.2. 10. 2 In ηA ,mA ,A mod e
3.2. 10. 3 In Hz m ode
3.2. 10. 4 Dut y rat io
4. Ope rat ing i nst ruc tio ns
4.1 AC/ DC Vol tag e mea sur eme nt
4.2 AC/ DC Cu rre nt me asu rem ent
4.3 Re sis tan ce me asu rem ent
4.4 Co nti nui ty me asu rem ent
10 10 10 11 11 11 12 12 13 13 13 13 14 14 15 16 16 16 17 18
Contents
1 1 2 3 4 5 5 7 8 8 9 9
4.5 Di ode t est
4.6 Ca pac ita nce m eas ure men t
4.7 Tra nsi sto r mea sur eme nt
4.8 Fr equ enc y mea sur eme nt
4.9 No n-c ont act v olt age (NC V) me asu rem ent
4.10 W ire les s ope rat ion
5. Mai nte nan ce
5.1 Ge ner al Ma int ena nce
5.2 Re pla cin g the b att ery
5.3 Re pla cin g the f use
5.4 Re pla cin g the P rob e
6. Ac ces sor ies
18 19 19 20 20 21 21 21 22 22 22 23
Page 3
1. Safe ty sta ndar ds
The multimeter meets the following safety standards: EN/UL/CSASTD C22.2 NO. 61010-1,61010-2-030, 61010-2-033for electronic testing instruments. This meter meets CAT III 600V installations and a pollution degree of 2.
• The protection provided by the meter can only be ensured if all safety procedures are strictly followed.
• The safety symbols on the meter are to advise of potential dangerous situations. Caution is required when measuring close to the meter’s safety limits.
• Never exceed the protection limit values indicated in the specifications for each range of measurement.
WARNING The special attention should be paid when using the meter because the improper usage may cause electric shock and damage the meter. The safety measures in common safety regulations and operating instruction should be complied with when using. In order to make fully use of its functions and ensure safe operations please comply with the usage in this section carefully.
1.1 FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Page 4
1.3 Saf ety st anda rds
Important safety information.
High voltage with danger.
Ground.
Double Insulation (Class II safety equipment).
Fuse must be replaced as per the specification herein.
AC (Alternating Current)
DC (Direct Current)
AC & DC (Both direct and Alternating Current)
Conforms to UL STD. 61010-1, 61010-2-030, 61010-2-033; Certified to CSA STD C22.2 NO. 61010-1, 61010-2-030,61010-2-033
Complies with Eur ope an (E U) sa fet y sta nda rds
CAT III: MEASUREMENT CATEGORY III is applicable to test and measuring circuits connected to the distribution part of the building's low-voltage MAINS installation.
Page 5
-The m ult ime ter i s a por tab le, h and -he ld ye t pro fes sio nal mete r tha t fea tur es tr ue RM S mea sur eme nt di spl ay, AC/ DC cur ren t, AC/ DC vo lta ge, F req uen cy, Ca pac ita nce, Resi sta nce , Com mun ica tio n, no n-c ont act v olt age t est s and hE F tes ts. T his m ete r is ea sy to u se even with one hand , sui tab le fo r pro fes sio nal u ser o r ama teu rs, a nd idea l for s cho ol or h ome u se.
- Both a uto a nd ma nua l ran ge.
-Displa y hol d.
-Tr ue RM S for AC v olt age / cur ren t mea sur eme nts .
-Relati ve me asu rem ent .
-Aut oma tic P owe r OFF.
No. Descrip tio n No. Descrip tio n
1 2 3 4 5 6 7
LCD di sp lay
Hold /B KL
Freq ue ncy /D ut y-c yc le
Wire le ss
Rota ry s wit ch
Inpu t ja ck (V,R ,D,F,C)
Comm on j ack
8
Inpu t ja ck (h FE ,μ A,m A)
9 10 11 12 13 14
Inpu t ja ck (1 0A ) Func ti on bu tt on
Rang e bu tto n
Rela ti ve bu tt on Volta ge a ler t li ght Volta ge a ler t ar ea
Page 6
2.2 But tons /Inp ut jac k desc ript ion
FUNC butt on:
• Pres s “FU NC” t o swi tch b etw een AC /DC o r bet wee n func tio n in a ro tar y swi tch p osi tio n.
HOLD b utt on:
• Pres s “HO LD” t o kee p the c urr ent r ead ing o n scr een . “H” sy mbo l wil l app ear o n the d isp lay.
• Pres s “HO LD” a gai n to re lea se th h old . butt on:
• Pres s “ ” to tu rn on t he ba ckl igh t. th e bac kli ght w ill turn o ff au tom ati cal ly af ter 1 5 sec ond s
RANGE but ton :
• Pres s “RA NGE ”to s wit ch to m anu al ra nge .Ea ch pr ess of the b utt on wi ll sw itc h to th e nex t hig hes t ran ge, u nti l reac hin g the h igh est r ang e whe re it w ill s wit ch to t he lowe st ra nge .
• Hold “RAN GE” t o ret urn t o aut o ran ge. butt on:
• With t he ro tar y swi tch i n any p osi tio n oth er th an OF F, pres s to en abl e the W ire les s com mun ica tio n fun cti on of the m ete r. Ope n the a pp (i OS or An dro id) o n the mobi le de vic e to be u sed a nd se arc h for t he mu lti met er and es tab lis h a con nec tio n. On ce co nne cte d, th e app will m irr or th e dis pla y of th e met er an d sho w any meas ure men t bei ng pe rfo rme d. Pr ess a gai n to disc onn ect t he me ter f rom t he mo bil e dev ice .
Hz/D UTY b utt on:
• Pres s “Hz /DU TY” t o sta rt th e fre que ncy c oun ter.
• Pres s “Hz /DU TY” a gai n to en ter d uty -cy cle m ode .
• Pres s “Hz /DU TY” a gai n to ex it th e fre que ncy c oun ter mode .
REL bu tto n:
• Pres s “RE L” to e nte r and e xit t he re lat ive m eas ure men t mode .
07 08
2.3 Auto po wer of f func tion
• After 1 5 min ute s of no n-u se th e met er wi ll au tom ati ca­ lly tu rn it sel f off .
• To turn th e met er ba ck on , pre ss “F UNC ”.
• To deact iva te th e aut o pow er off fu nct ion , hol d dow n “FUN C” wh en tu rni ng on t he me ter. w ill n o lon ger b e disp lay ed.
2.4 LCD D ispl ay
6 7 8 9 10 11 12
13
5
4 3 2 1
No. Descrip tio n
1 2 3 4 5 6 7 8
DC (di re ct cu rr en t)
AC (al te rna ti ng c urr en t)
Pola ri ty in di ca tor
Wire le ss in di ca tor
Auto p ow er off indi ca tor
Auto -r ang e
Tra ns ist or t est mod e
Rela ti ve me as ur eme nt
16
No. Descrip tio n
9 10 11 12 13 14 15 16
14
15
Data h ol d
Tru e ro ot me an s quare
Diod e me asu re me nt
Cont in uit y bu zz er
Low ba tt ery i nd ic ato r
Unsa fe v olt ag e wa rni ng
Meas ur eme nt u ni ts
Main d is pla y
Page 7
Symb ol
V, mV
A,mA ,µ A
Ω Ω Ω,K ,M
Hz,K Hz ,MH z
Hz,K Hz ,MH z
V: mV:
A: mA: µA:
Ω: kΩ : MΩ :
Hz: KHz: MHz:
F: mF: μF: nF:
Descrip tio n
Volts . Th e un it of vol ta ge. Mill iv olt . 1x 10 o r 0.0 01 v olts.
Ampe re s (am ps ). T he u nit o f cu rrent . Mill ia mp. 1 x1 0 or 0 .00 1 am per es . Micr oa mp. 1 x1 0 or 0 .00 00 1 amp er es .
Ohm. The u ni t of resi st anc e. Kilo hm . 1x1 0 or 1 00 0 ohm s. Mego hm . 1x1 0 or 1 ,0 00, 00 0 ohm s.
Hert z. T he u nit of fr eq uen cy. Kilo he rtz . 1x 10 o r 100 0 he rtz . Milo he rtz . 1x 10 o r 1,0 00 ,000 he rt z.
Fara d. T he u nit of ca pa cit an ce. Mill if ara d. 1 x1 0 or 0. 00 1 farad s. Micr of ara d. 1 x1 0 or 0. 00 000 1 fa ra ds. Nano fa rad . 1x 10 o r 0.0 00 000 00 1 fa rad s.
-3
-3
-6
3
6
3
6
-3
-6
-9
3. Tech nica l spec ific atio ns
Accu ran cy: ± ( % rea din g + dig its ) a t 18~28 wit h a relativ e hum idi ty of < 80% ; gua ran tee d for a p eri od of one year.
3.1 Gen eral s peci fica tion s
Safe ty Ra tin g: CAT III 6 00V, pol lut ion d egr ee of 2 Oper ati ng Alt itu de: < 200 0m Oper ati ng Temp era tur e/H umi dit y: 0~ 40, <8 0% RH Stor age Tem per atu re/ Hum idi ty: - 10~ 60, <7 0% RH , remo ve ba tte ry Max. I npu t bet wee n ter min als a nd ea rth g rou nd: 6 00V D C or AC True -RM S Fuse P rot ect ion : A/mA ra nge s: FF 4 00m A H 1000 V 10A ran ge: F F 10A H 60 0V Display: 3³⁄ 4 dig it LC D dis pla y Over loa d Ind ica tio n: Di spl ay sh ows “ OL”
Low Batte ry In dic ati on: W hen b att ery v olt age d rop s bel ow norm al op era tin g vol tag e, “ ” is show n on th e dis pla y Polarit y Ind ica tio n: Di spl ay au tom ati cal ly di spl ays “ -” Power Sup ply : DC 9V ( NED A 1604 , 6F2 2 or 00 6P) Wire les s Com mun ica tio n Dis tan ce: Indo or/ Out doo r: <1 0m Support ed App OS: iO S: 7. 0 and a bov e Andro id: 4 .3 an d abo ve Size (Lx WxH ): App rox . 92x 188 x50 mm Weig ht: Ap pro x. 43 2g
3.2 Tec hnic al ind icat ors
3.2.1 D c volt age
400mV
4.0V 40V
400V
±( 1% of r ead ing + 5 d igi ts )
600V
600V DC or AC True-RMS.
- Max. i npu t vol tag e: 60 0V DC o r AC True -RM S.
3.2.2 Ac vo ltag e
400mV
4.0V 40V
400V
600V
±( 1.0 % of re adi ng + 8 di git s )
±( 1.2 % of re adi ng + 8 di git s )
09 10
Page 8
- Inpu t imp eda nce : 10M
- Max. i npu t vol tag e: 60 0V DC o r AC True -RM S.
- Freq uen cy re pon se: 4 0~4 00H z
- Resp ons e: Tru e-R MS
3.2.3 R esis tanc e
400Ω
4KΩ
40KΩ
400KΩ
4MΩ
40MΩ
- Over loa d pro tec tio n: 60 0 DC or AC Tr ue- RMS
±( 0.8 % of re adi ng + 3 di git s )
3.2.6 D C curr ent
400μA
4000μA
40mA
400mA
10A
- Over loa d pro tec tio n: mA jack : FF 40 0mA H 10 00V 10A jack: FF 1 0A H 600 V
- Max in put c urr ent : mA jack : 400 mA 10A jack: 10 A
0.01 mA
0.1m A
±( 1.0 % of re adi ng + 10 d igi ts )
3.2.7 AC cu rren t
3.2.4 D iode t est
1mV2.7V
- Over loa d pro tec tio n: 60 0V DC o r AC True -RM S
Displays sho ws fo rwa rd voltage d rop
3.2.5 C onti nuit y
Open c irc uit voltage ~1 V
- Over loa d pro tec tio n: 60 0V DC o r AC True -RM S
11 12
400μA
4000μA
40mA
400mA
10A
- Over loa d pro tec tio n: mA jack : FF 40 0mA H 10 00V 10A jack: FF 1 0A H 600 V
- Freq uen cy re spo nse : 40~ 400 Hz, t rue R MS re spo nse
- Max in put c urr ent : mA jac k: 40 0mA DC o r AC rms 10A jac k: 10 A DC or AC rm s
- When m eas uri ng cu rre nt ex cee din g 2A, d o not m eas ure for lo nge r tha n 2 min ute s con tin uou sly. Wa it 10 m inu tes
to con tin ue me asu rem ent .
0.01 mA
0.1m A
±( 1.5 % of re adi ng + 5 di git s )
±( 3.0 % of re adi ng + 5 di git s )
Page 9
3.2.8 h FE tra nsis tor ga in
Descripti on
hFE
- Base c urr ent : app rox . 5µA
- Vce: a ppr ox. 1 .6V
- Prot ect ion : FF 40 0mA H 10 00V
Displays app rox . hFE t ran sis tor gain (0-1 000 )
3.2.9 C apac tanc e
9.99 9nF
99.9 9nF
999.9nF
9.99 9μF
99.9 9μF
999.9μF
9.99 9mF
99.9 9mF
- Over loa d pro tec tio n: 60 0 DC or AC Tr ue- RMS
±( 5.0 % of re adi ng + 5 di git s )
±( 4.0 % of re adi ng + 5 di git s )
3.2.1 0 Freq uenc y
3.2.1 0.1 In V m ode
99.9 9Hz
999.9Hz
9.99 9KH z >10KHz
- Inpu t vol tag e ran ge: > 3V AC (Tru e-R MS) ( higher in put v olt age a t hig her f req uen cy )
- Inpu t imp eda nce : 10M Ω
- Max. inp ut vo lta ge: 6 00V AC ( Tr ue- RMS )
=
3.2.1 0.2 In μ A,mA ,A mode
99.9 9Hz
999.9Hz >1KH z
-Inpu t cur ren t ran ge: μA range:> 1 00μ A AC(Tr ue- RMS )
mA range: > 10 mA AC (True -RM S)
A range: > 5A AC(True -RM S) ( higher in put c urr ent a t hig her f req uen cy )
- Max. inp ut cu rre nt:
μA range: 400mA AC(Tru e-R MS) mA range: 40 0mA AC(Tru e-R MS) A range: 10 A AC( True-RMS)
=
=
=
3.2.1 0.3 In H z mode
9.99 9Hz
99.9 9Hz
999.9Hz
9.99 9KH z
99.9 9KH z
999.9KH z
9.99 9MH z
0.00 1Hz
±( 0.5 % of re adi ng + 3 di git s )
0.1k Hz
0.00 1mH z
13 14
Page 10
- Inpu t vol tag e ran ge: > 2V AC (Tru e-R MS) ( higher inp ut vo ltage at hi gher fre quency )
=
- Max.inpu t vol tage: 600 V AC (True-RMS)
3.2.1 0.4 Du ty rat io
0.1% -99 .9%
By μA, m A, A r ang e:
- Inpu t cur ren t ran ge: μA rang e: > 10 0μA AC (Tru e-R MS) mA rang e: > 10 mA A C (Tru e-R MS) A ran ge: > 5 A AC (True-RM S) ( high er in put c urr ent a t hig her f req uen cy )
=
=
=
- Max. inp ut cu rre nt: μA rang e: 40 0mA AC (Tru e-R MS) mA rang e: 40 0mA AC (Tru e-R MS) A ran ge: 1 0 A AC ( Tr ue- RMS )
• By V ran ge:
- Inpu t vol tag e ran ge: > 3 V AC (True -RM S) ( high er in put v olt age a t hig her f req uen cy )
- Inpu t imp eda nce : 10M Ω
=
- Max. inp ut vo lta ge: 6 00V AC ( Tr ue- RMS )
• By Hz ra nge :
- Inpu t vol tag e ran ge: > 2V AC (Tru e-R MS) ( high er in put v olt age a t hig her f req uen cy )
=
- Max. inp ut vo lta ge: 6 00V AC ( Tr ue- RMS )
±3.0%
4. Oper atin g inst ruct ions
4.1 AC/DC Volta ge mea sure ment
Set th e rot ary s wit ch to t he AC or D C vol tag e pos iti on.
Conn ect t he re d tes t lea d to th e inp ut ja ck an d the
blac k lea d to th e COM j ack .
Conn ect t he le ads t o the c irc uit u nde r tes t and r ead t he meas ure men t on th e dis pla y. Obs erv e pol ari ty for DC meas ure men t. In m anu al mo de, i f “OL ” is di spl ay it mean s the m eas ure men t has e xce ede d the c urr ent rang e. In cre ase t he se lec ted r ang e and m eas ure a gai n.
WARNING
Do not measure voltages higher than 600V DC or AC rms to prevent damage to the meter or personal injury.
WARNING
Never measure open-circuit voltages exceeding 600V between the input terminals and ground to prevent injury or damage to the meter.
4.2 AC/DC C urre nt mea sure ment
Tur n off pow er to t he ci rcu it. Al low a ll ca pac ito rs to disc har ge.
Set th e rot ary s wit ch to t he ap pro pri ate AC /DC c urr ent volt age .
Pres s “FU NC” t o swi tch b etw een AC a nd DC c urr ent .
Depe ndi ng on t he cu rre nt to b e mea sur ed, c onn ect t he red te st le ad to e ith er th e inp ut or 1 0A jac k and t he bl ack lead t o the C OM ja ck.
Brea k the c irc uit a nd co nne ct th e lea ds in s eri es wi th the ci rcu it (b lac k lea d on th e low er vo lta ge si de) .
15 16
Page 11
Tur n cir cui t pow er on a nd re ad th e mea sur eme nt on t he disp lay, i t mea ns th e mea sur eme nt ha s exc eed ed the curr ent r ang e. Mo ve th e rot ary s wit ch to a h igh er ra nge .
Note :
- Check fus es be for e mak ing c urr ent m eas ure men ts. M ake sure t o use c orr ect i npu t jac ks to p rev ent d ama ge to t he mete r.
4.3 Res ista nce me asur emen t
Tur n off the p owe r to th e cir cui t. All ow al l cap aci tor s to disc har ge.
• Set th e rot ary s wit ch to t he mu lti -fu nct ion p osi tio n. The defa ult f unc tio n is re sis tan ce.
• Connect the re d tes t lea d to th e inp ut ja ck an d the b lac k lead t o the C OM ja ck.
• Connect the le ads t o the c irc uit u nde r tes t and r ead t he meas ure men t on th e dis pla y.
Tips f or me asu rin g res ist anc e:
• In-c irc uit r esi sta nce i s usu all y dif fer ent f rom a resistors rati ng du e to th e fac tth at th e met er’s t est c urr ent f low s in para lle l wit h the c irc uit .
• For in cre ase d acc ura cy wh en me asu rin g low r esi sta nce , shor t the t est l ead s, re cor d the t est d isp lay ed, t hen conn ect t he le ads t o the c irc uit a nd su btr act t he sh ort ed valu e fro m the c irc uit m eas ure men t.
• When t he le ads a re di sco nne cte d fro m the c irc uit u nde r test , “OL ” wil l be di spl aye d on th e scr een .
WARNING
To prevent injury or damage to the meter, turn off power to circuitand discharge all capacitors fully before making resistance measurements.
4.4 Con tinu ity me asur emen t
Tur n off the p owe r to th e cir cui t. All ow al l cap aci tor s to disc har ge.
Set th e rot ary s wit ch to t he mu lti -fu nct ion p osi tio n. Pres s “FU NC” t wic e to en ter c ont inu ity m ode .
Conn ect t he re d tes t lea d to th e inp ut ja ck an d the b lac k lead t o the C OM ja ck.
Conn ect t he le ads t o the c irc uit u nde r tes t. If t he meas ure d res ist anc e is le ss th an 50 Ω,th e buz zer w ill soun d.
WARNING
To prevent injury or damage to the meter, turn off power to circuit and discharge all capacitors fully before making continuity measurements.
4.5 Dio de tes t
Tur n off the p owe r to th e cir cui t. All ow al l cap aci tor s to disc har ge.
Set th e rot ary s wit ch to t he mu lti -fu nct ion p osi tio n. Pres s “FU NC” o nce t o ent er di ode m ode .
Conn ect t he re d tes t lea d to th e inp ut ja ck an d the b lac k lead t o the C OM ja ck.
Conn ect t he re d tes t lea d to th e ano de (+ ) and t he bl ack lead t o the c ath ode ( -) of t he di ode a nd re ad th e mea s­ urem ent o n the d isp lay. The me ter w ill d isp lay “ OL” i f the c onn ect ion i s res erv ed.
WARNING
To prevent injury or damage to the meter, turn off power to circuit and discharge all capacitors fully before making diode measurements.
17 18
Page 12
4.6 Cap acit ance m easu reme nt
Tur n off the p owe r to th e cir cui t. All ow al l cap aci tor s to disc har ge.
Set th e rot ary s wit ch to t he mu lti -fu nct ion p osi tio n. Pr ess “FUN C” th ree t ime s to at iva te ca pac ita nce t est .
Conn ect t he bl ack a nd re d tes t lea ds to t he CO M and term ina ls re spe cti vel y (or y ou ca n mea sur e the c apa cit an­ ce by us ing t he sp eci al mu lti -fu nct ion s ock et) .
Conn ect t he te st le ads t o the c apa cit or be ing m eas ure d and re ad th e dis pla yed v alu e.
Some t ips f or me asu rin g cap aci tan ce:
The me ter m ay ta ke a fe w sec ond s to st abi liz e rea din g. This i s nor mal f or fo r hig h cap aci tan ce me asu rin g.
To impro ve th e acc ura ncy o f mea sur eme nts l ess t han 10nF, su btr act t he re sid ual c apa cit anc e of th e met er an d lead s.
WARNING
To avoid eletrical shock and/or damage to the instrument, disconnect circuit power and discharge all high-voltage capacitors before measuring capacitance. Use the DC voltage function to confirm that the capacitor is discharged.
4.7 Transist or mea sure ment
Set th e rot ary s wit ch to h FE ra nge .
Conn ect t he “C OM” p lug a nd “+ ” plu g of th e spe cia l
mult i-f unc tio n soc ket t o the C OM an d hFE t erm ina ls.
Dete rmi ne wh eth er th e tra nsi sto r to be t est ed is N PN or PNP t ype a nd lo cat e the E mit ter, B ase a nd Co lle cto r lead s.
Inse rt le ads o f the t ran sis tor i nto p rop er ho les o f the spec ial m ult i-f unc tio n soc ket .
The me ter w ill s how t he ap pro x.
WARNING
To avoid eletrical shock and/or damage to the instrument, do not apply more than 36Vdc or 36Vac rms between the hFE terminal and the COM terminal.
4.8 Fre quen cy mea sure ment
Set th e rot ary s wit ch to H z% ra nge .
Conn ect t he bl ack a nd re d lea ds to t he CO M and H z
term ina ls re spe cti vel y.
Conn ect t he te st le ads t o the c irc uit b ein g mea sur ed.
Read t he di spl aye d val ue.
WARNING
Do not measure frequency on high voltage (>250V) to avoid electrical shock hazard and/or damage to the instrument.
4.9 Non -con tact v olta ge(N CV) me asur emen t
Set th e rot ary s wit ch to t he NC V pos iti on.
Move t he to p of th e met er to war d the v olt age s our ce. I f
volt age i s det ect ed (> 100 V AC), t he me ter w ill b eep and th e NCV i ndi cat or wi ll fl ash . The c los er to t he volt age s our sce t he me ter i s, th e fas ter t he me ter w ill beep /fl ash .
Note :
- Even w ith out i ndi cat ion , vol tag e may s til l pre sen t. Do n ot repl y sol ely o n NCV d ete cti on to d ete rmi ne th e pre sen ce of vol tag e. De tec tio n cou ld be i mpa ire d by so cke t des ign , inso lat ion t hic kne ss, o r oth er fa cto rs.
- Exte rna l int erf ere nce s our ces c oul d mis tak enl y tri gge r
19 20
Page 13
NCV in dic ati on.
4.10 Wi rele ss ope rati on
With t he ro tar y swi tch i n any p osi tio n oth er th an OF F, pres s to en abl e the W ire les s com mun ica tio n of th e met er.
Open t he ap p (iO S or And roi d) on t he mo bil e dev ice t o be used a nd se arc h for t he mu lti met er an d est abl ish a conn ect ion . Onc e con nec ted , the a pp wi ll mi rro r the d isp lay of the m ete r and s how a ny me asu rem ent b ein g per for med .
Pres s aga in to d isc onn ect t he me ter f rom t he mo bil e devi ce.
5. Maintenance
5.1 General Maintenance
This section provides basic information on maintaining the meter, such as replacing fuses and the battery. Only experienced and authorized personnel should make repairs to the meter.
WARNING To avoid injury or damage to the meter,do not allow moisture inside the case and remove test leads before opening battery cover.
• Use a damp cloth to regularly clean the outside of the meter. Do not use abrasives or chemical solvents. Dirty or damp input jack can adversely affect readings.
• To clean input jacks, follow the following steps:
1.Turn off the instrument and remove the test leads.
2.Clear any dirt or other particles on the input jacks.
3.Use a cotton ball/swab with a lubricant (i.e. WD-40) to clean off the contacts of the input jacks.
4.Use a separate cotton ball/swab for each jack to prevent cross-contamination.
21 22
5.2 Replacing the Battery
WARNING
To avoid false readings and potential dangerous situations, replace the battery immidately when the “ ” symbol appears. Turn off the meter and disconnect the test leads before opening the battery cover to prevent electrical shock and personal injury.
Use the following steps to replace the battery:
1.Turn off the meter.
2.Remove test leads.
3.Unscrew and remove battery cover from back of meter.
4.Replace used battery with a new 9V battery.
5.Replace battery cover and fasten securely.
5.3 Replacing the Fuse
WARNING
Turn off the meter and disconnect test leads before opening back cover to avoid electical shock and personal injury.
Use the following steps to replace the fuses:
1.Turn off the meter.
2.Remove test leads.
3.Remove outer holster.
4.Unscrew and remove back cover from the meter.
5.Replace blown fuse(s) with same amp/voltage ratings.
6.Replace back cover and fasten securely.
7.Replace outer holster.
5.4 Replacing the Probe
Ifinsulationonprobeisdamaged,replaceit.
WARNING
Use meet EN61010-031 standard, ratedCAT III 600V, 10A or better probe.
Page 14
Pack age
Multi-F unc tio n Soc ket
1 set
23
R-00-05-2 149
Loading...