Mastech MS8218 Instruction Manual

MS8218 True RMS Multimeter
Contents
Contents
Chapter 1 Safety Information
Meter Safety Standards………………………………………………………………………………………………….
Warning………………………………………………………………………………………………………………….
Chapter 2 Introduction to the Meter
Characteristics………………………………………………………………………………………….……………..…
Explanation on Front Panel……………………………………………………………………………………………...
Understanding Display Screen…………………………………………………………………………………………..
Function Descriptions……………………………………………………………………………………..…………….
Chapter 3 Operation Methods
ACV/dBm Measurement…………………………………………………………………………………………………
DCV/DCV+ACV Measurement…………………………………………………………………………………………
DC mV/AC mV /DC mV+AC mV Measurement……………………………………………………………………….
Logic Frequency/Duty Ratio Measurement……………………………………………………………….…………….
Diode Measurement……………………………………………………………………………………………………..
Resistance/continuity Measurement…………………………………………………………………………………….
Capacitance Measurement………………………………………………………………………………………………
DC μA /AC μA/DC μA +AC μA Measurement…………………………………………………………………
I
1
1
2
3
8
11
14
16
18
20 22
24
26
28
4
MS8218 True RMS Multimeter
Contents
DC mA/AC mA/DC mA +AC mA Measurement……………………………………….………………………………
DC Ampere/AC Ampere/DC Ampere+AC Ampere Measurement……………………….…………………………….
Linear Frequency Measurement……………………………………….…………….……………….………..…………
Relative Value Measurement………………………………………………………….…………………………………
Maximum Value/Minimum Value/Maximum Value-Minimum Value Measurement………………………….………
Backlight Control……………………………………………………………………………………………….……….
Data Hold………………………………………………………………………………………………………………..
Automatic Shutdown and Continuous Operation Mode Selection………………………………………………………
Connected to RS-232C Interface Of Computer…………………………………………………………………………
Chapter 4 Technological Specifications
General Features…………………………………………………………………………………………………………
Range and Accuracy……………………………………………………………………………………………………..
Chapter 5 Maintenance
Replacement of Batteries………………………………………………………………………………………………..
Replacement of Fuse…………………………………………………………………………………………………….
Meter Calibration………………………………………………………………………………………………………..
Others ………………………………………………………………………….………..………………………………
II
30 32
34
35 35
36
36
36
37
38 39
43
43
44
44
MS8218 True RMS Multimeter
Safety Information
Chapter 1
Meter Safety Standards
This style of digital multimeter is designed and manufactured according to the safety requirements set out by the IEC1010-1
standards for electronic test instruments and the hand-hold digital multimeters. Its design and manufacture is strictly based on
the provisions in the 1000V CAT
of IEC1010-1 and the Stipulation of 2-Pollution Grade.
The meter conforms to the European Union’s following requirements:89/336/EEC
(EMC Electromagnetic Compatibility ),73/23/EEC(LVD Low Voltage Protection)and 93/68/EEC(CE Mark).
Warning
Before use of the meter firstly check up if there is any crack on the outer shell or if it lacks any plastic part, and check up
whether the testing line is damaged or has any exposed metal. The meter can be used only if no any insulating problem be
found.
Carefully read the operating methods and safety prompts in this manual. Using it not based on the methods specified in
this manual may cause the meter damaged.
Non-normal meter must not be used. It should be sent for repairing.
The meter must not be used in an environment with combustible gases, steam or dust pollution.
It should be careful to work when measuring votage higher than 30Vac(effective value)or 50Vdc for such voltage having
the risk of shock. Avoid the body directly touching ground or any metal substance in which there may be ground
1
MS8218 True RMS Multimeter
Safety Information
potential during measuring. The body should be kept insulated from ground with dry insulating shoes, insulating pads or
insulating clothes.
When performing measurement with a test probe your fingers should be put behind a finger-protector.
Must not try to measure a voltage higher than 1000VAC or 1000VDC,the meter may be damaged and the operator’s safety
may be threatened if the limit for voltage measurement be exceeded.
when the symbol for electric insufficiency appearing on the display screen it is necessary to replace the batteries for
avoiding the possible shock or injure resulted in by erroneous reading.
In case of replacing batteries, it is necessary firstly to pull out the testing line. AA batteries should be used and they should
be put into the meter with the proper polarity.
Must not make any voltage measurement when the testing line being inserting into the current hole.
Repair and calibration of the meter must be carried out by experienced professionals, unprofessionals should not repair and
calibrate the meter by themselves.
Limited Guarantee and the Liability Scope
This company will undertake repairs freely for any quality problem of the meter which if should be found within 18 months
from the date at which it was bought, but which not including replacement of fuse and batteries as well as any damage caused
by negligence, wrong use, pollution, change of circuit and non-normal use.
For maintenance beyond the 18-month guarantee period, the company will charge a certain repair fee and materials cost.
2
MS8218 True RMS Multimeter
Introduction to the Meter
Chapter 2
Characteristics
50000 counts measurement
ACV and DCV measurements reach up to 1000V.
DC measurement accuracy reaches up to 0.03%.
0.01
Ω
resistance resolution and 1μV voltage resolution.
Linear frequency measurement, logic frequency/duty ratio measurement.
Capacitance measurement from 0.01nf to 5000μF.
AC/DC true RMS measurement.
DBm measurement
Maximum value/minimum value measurement, Relative measurement.
50-segment analog bar display.
Automatic shutdown/continuous working mode selection.
Back light control.
RS-232C infrared interface.
Display, record and graphics software of computer.
Overload protection.
Sound alarm for wrong current measurement.
Secondary plasticizing meter shell, with insulating performance reaching 1000V CAT
3
MS8218 True RMS Multimeter
Introduction to the Meter
Explanation on Front Panel
The front panel is shown as in Figure 2-1,
explanation being as follows:
4
MS8218 True RMS Multimeter
Introduction to the Meter
(1) VΩHz end
It is the input end for all measurement functions except for current measurement, connected with a red meter probe.
(2) COM end
It is the negative input end for all measurements, connected with a black meter probe.
(3)µA/mA end
It is the positive end for measurement of µA or mA current, connected with a red meter probe.
(4)A end
It is the positive input end for measurement of 0.5A-10A current, connected with a red meter probe.
(5)Rotary switch
Used for selecting measurement functions such as voltage, current, resistance and Capacitance.
(6)POWER switch
Used for putting on or off the operating power for the meter.
(7)RANGE key
For various kinds of measurements it is used manually to select range. Under the automatic range state (AUTO displaying), it
will enter manual range state(MANUAL displaying) with a press on RANGE, after that the range will be changed with a press
on RANGE while the small digits on the left lower corner indicating the actual range. When the RANGE key being released
after pressing for two seconds the meter will return back to the automatic state. When performing logic frequency measurement
and diode measurement pressing RANGE will be void. During dBm measurement, pressing RANGE key will alter the virtual
resistance value for calculating dBm.
5
MS8218 True RMS Multimeter
Introduction to the Meter
(8) SELECT key
When setting the rotary switch to a measurement function, the meter will enter its first measurement mode, while pressing the
SELECT key it is possible to select the second or the third measurement mode. However, there is only one for the diode and
Capacitance measurements.
(9)WAKE key
After the meter being automatically shutdown, by pressing the WAKE key it can be woken up to resume the measurement. In
case of pressing POWER switch(for putting on the unit) and WAKE key simultaneously, the meter will in a continuously
working state without the automatic shutdown function.
(10)MAX/MIN key
Press MAX/MIN key to enter the record state for the maximum and minimum value and simultaneously display the maximum
value. By pressing this key again it will be possible to display the minimum value and the maximum value-minimum value.
When releasing the key after pressing it for two seconds, the maximum and minimum record state will be exited. Pressing this
key will be void during frequency
diode measurement.
(11)REL key
By pressing REL to enter the relative measurement state, the meter will remember the value measured at the time when
pressing the key(it is called the initial value), and after that the value displayed in the meter will be equivalent to the present
value – the initial value. By pressing the key again the relative measurement state will be exited. Pressing the key will be void
during the frequency and diode measurements.
6
MS8218 True RMS Multimeter
Introduction to the Meter
(12)HOLD key
Used to maintain the measurement data unchanging, by pressing the key again it will resume the measurement. When
releasing the key after pressing it for two seconds, the meter will enter the state connecting with the RS-232C interface of
computer while sending measurement information to computer. When releasing the HOLD key after pressing it for two seconds
again, it will stop to send data to the RS-232C interface.
(13)LIGHT key
By pressing this key for a time, the backlight of the LCD screen will be opened and after five seconds the meter will
automatically turn off the backlight. It is also possible to turn off the backlight by pressing the LIGHT key before the five
seconds.
(14)
Hz key
During the voltage or current measurements, by pressing Hz key the meter will enter the linear frequency measurement
state. At this time what being measured is the frequency of voltage or current. By pressing this key again it will exit the linear
frequency measurement state.
(15)LCD screen
Used for displaying the measuring results and various symbols.
7
MS8218 True RMS Multimeter
Introduction to the Meter
Understanding Display Screen :
Figure 2—2
8
MS8218 True RMS Multimeter
Introduction to the Meter
LCD screen is shown as in Figure 2-2, with its every symbol’s meaning shown as in the Table 1:
Number of Order Symbol Functions
1
Indicating the measurement unit being or of temperature
1
mnF
Indicating the measurement unit being μF or nF of Capacitance
1
m
μμμμ
A
Indicating the measurement unit being μA,mA or A of current
1
dBmV
Indicating the measurement unit being dBm of power or mV and V of voltage
1
MK
ΩΩΩΩ
Hz
Indicating the measurement unit being MΩ,KΩand Ω of resistance or MHz, KHz and Hz of frequency
2
Indicating the measurement unit being the duty ratio of logic impulse
3
MAX-MIN
Indicating the display value being the maximum value(MAX),the minimum value(MIN) or the maximum value-the minimum value(MAX-MIN)
4
AUTO
Indicating the measurement being automatic range
5
MANUAL
Indicating the measurement being manual range
6
51000
Indicator of range, indicating the full range value of this range in manual range such as 5, 50, 500 and 1000,5000, etc.
7
Indication to low voltage of the batteries, showing the energy of batteries will be exhausted soon
8
Indicating the measurement being relative measurement while the displayed value being relative value
9
Indicating it is now performing the continuity measurement
9
MS8218 True RMS Multimeter
Introduction to the Meter
Tabel1 (continue)
10
AC
Indicating it is now in the AC measurement state, while DC and AC displaying simultaneously, indicating it is DC+AC measurement
11
Indicating the measurement vale being negative
12
DC
Indicating it is now in the DC measurement state, while DC and AC displaying simultaneously, indicating it is DC+AC measurement
13
Indicating it is now in the data-holding state
14
Please Wait ...
When measuring 50μF5000μF capacitor under automatic range, for ensuring the accuracy of measurement, it is necessary to perform the measurement after fully discharging capacitor while prompting the operator to wait
15
Analog bar, indicating the measurement value with a graphic mode
16
Indicating the meter being in the state for sending data to the RS-232C interface of computer
17
The display zone for the meter’s measurement value, showing all the measurement values
10
MS8218 True RMS Multimeter
Introduction to the Meter
Function Descriptions
Along with the conventional measurement functions this meter also possesses some special functions which being described as
follows:
True effective value (TRUE RMS) measurement: all the measurement values of this meter on the AC voltage and AC
current are true effective values, which distinguishing this meter from the low-grade meters which only can measure the AC
average value.
dBm measurement: dBm measurement is a value calculated and displayed under the current AC voltage, with a virtual
resistance R obtained through RANGE key and according to the following formula:
It is the AC power expressed in the logarithmic form.
DC+AC measurement: when measuring voltage or current having both the AC and the DC components, in case of selecting
the DC+AC measurement mode, this meter will perform measurements on both DC and AC components respectively and
then calculate and display the results according to the following formula:
DC+AC measurements reflect the general effective values generated jointly by both the DC and AC components.
Automatic and manual ranges: When turning on the meter’s power switch the meter defaults the automatic range
state(AUTO displaying), and simultaneously it will automatically select the proper range according to the measured electric
parameters. If OL being displayed under automatic range, it indicates the measured value exceeding the meter’s maximum
range. Pressing the RANGE key under the automatic range the meter will enter the manual range(MANUAL displaying),
then pressing the RANGE key again it will be possible to select the required range. The indicator for range will display the
maximum value of this range. If OL displaying under the manual range, it indicates the measured value exceeding the
11
MS8218 True RMS Multimeter
Introduction to the Meter
selected range. Press the RANGE key under the manual range for two seconds and then release it, the meter will go back to
the automatic range state.
Linear frequency measurement: Pressing the Hz key when the meter performing measurements on AC voltage or current
as well as on mixture signal of AC and DC, it will be capable to measure the frequency of the AC component. However it
has a certain requirements on the amplitude of the AC component.
Logic impulse duty ratio measurement: logic impulse duty ratio refers to (high level width/impulse cycle)×100%
Diode measurement: during diode measurement the meter is indicating to the forward voltage drop of the diode
Relative measurement: during relative measurement the meter remembers internally the instantaneously measured
value(called initial value)when pressing the REL Δ key, and the later displaying value being:
present value – initial value
The relative measurement value reflects the changes of the measured value. It also can be used to take off the errors
brought about by lead resistance or distributed capacitance during measuring low resistance and low capacitance. Due to
subtraction calculation, negative value may appear during measuring AC current, resistance and capacitance.
Maximum/minimum value measurement: by pressing MAX/MIN keys the meter can enter the maximum/minimum value
record state, and it will continuously update the maximum/minimum values based on the new measurement results. Pressing
the MAX/MIN key can display the maximum value, the minimum value and the maximum value-the minimum value in
cycles. After exiting the MAX/MIN measurement state the recorded maximum value/minimum values will disappear.
12