RUSH PAR 4 UV
100W COB 400nm UV PAR
SPEC SHEET
Bright Single-Lens UV LED Bar Is Ideal for Nightlife, Stage, and Concert Blacklight Applications
This UV LED PAR can light fixture includes a 100 watt COB 400nm UV LED mounted in a reflector for high-output ultraviolet light, and has regulated air cooling for quiet operation. With electronic dimming and strobe and a bracket suitable for floor or truss mounting, the RUSH PAR 4 UV is ideal for a variety of nightlife, stage, and concert applications.
Single-lens 100W UV LED PAR
The RUSH PAR 4 UV includes a 100 watt COB 400nm UV LED mounted in a reflector for high-output ultraviolet light.
Regulated air cooling
To ensure ultra-quiet operation, regulated air cooling is integrated.
Electronic dimming and strobe
With electronic dimming and strobe and a bracket suitable for floor or truss mounting, the RUSH PAR 4 UV is ideal for a variety of nightlife, stage, and concert applications.
HARMAN PROFESSIONAL DENMARK APS • OLOF PALMES ALLÉ 18 • 8200 AARHUS N • DENMARK HARMAN PROFESSIONAL SOLUTIONS U.S. • 8500 BALBOA BOULEVARD • NORTHRIDGE • CA 91329 • USA
©2018 HARMAN Professional Denmark ApS. All rights reserved. Martin is a registered trademark of HARMAN Professional Denmark ApS registered in the United States and/or other countries. Features, specifications, and appearance are subject to change without notice.
1/3
Page 2
RUSH PAR 4 UV
100W COB 400nm UV PAR
SPEC SHEET
FEATURES
100 watt COB 400nm UV LED
Regulated air cooling for quiet operation
Reflector system for high UV output
Electronic dimming and strobe
Bracket suitable for floor or truss mounting
Lightweight construction (4 kg / 8.8 lbs.)
ORDERING INFORMATION
RUSH PAR 4 UV in cardboard box: P/N 90480140
INCLUDED ITEMS
Power cable, 1.5 m without mains plug
RELATED ITEMS
Martin M-DMX with Martin Companion Uploader Software
OPTIONAL ACCESSORIES
Installation Hardware
Half-coupler clamp: P/N 91602005
G-clamp (vertical hanging suspension only): P/N 91602003
Quick-trigger clamp (vertical hanging suspension only):
P/N 91602007
Safety cable, 60Kg, BGV C1: P/N 91604006
Cables, 16 A, For Connection To Power In Chains
Power relay cable 3 x 2.5 mm2, H07RN-F
POWCON-POWCON 1.2 m (3.9 ft.): P/N 91611798
Power relay cable 3 x 14 AWG, SJOOW
POWCON-POWCON 1.2m (3.9 ft.): P/N 91610175
Power relay cable 3 x 2.5 mm2, H07RN-F
POWCON-POWCON 2.5m (8.2 ft.): P/N 91611799
Power relay cable 3 x 14 AWG,SJOOW
POWCON-POWCON 2.5m (8.2 ft.): P/N 91610176
Cables, 16 A, For Power Input
Power input cable 3 x 2.5 mm2, H07RN-F
OPEN-POWCON 1.5 m (4.9 ft.): P/N 91611800
Power input cable 3 x 14 AWG, SJOOW
OPEN-POWCON 1.5 m (4.9 ft.): P/N 91610177
Power input cable 3 x 2.5 mm2, H07RN-F
OPEN-POWCON 5.0 m (16.4 ft.): P/N 91611801
Power input cable 3 x 14 AWG, SJOOW
OPEN-POWCON 5.0 m (16.4 ft.): P/N 91610178 (H07RN-F are European approved cables, SJOOW are US approved cables)
Power Connectors
Power Connector PowerCON Male: P/N 91611795
Power Connector PowerCON Female: P/N 91611794
HARMAN PROFESSIONAL DENMARK APS • OLOF PALMES ALLÉ 18 • 8200 AARHUS N • DENMARK HARMAN PROFESSIONAL SOLUTIONS U.S. • 8500 BALBOA BOULEVARD • NORTHRIDGE • CA 91329 • USA
©2018 HARMAN Professional Denmark ApS. All rights reserved. Martin is a registered trademark of HARMAN Professional Denmark ApS registered in the United States and/or other countries. Features, specifications, and appearance are subject to change without notice.
2/3
Page 3
RUSH PAR 4 UV
100W COB 400nm UV PAR
TECHNICAL SPECIFICATIONS
SPEC SHEET
PHYSICAL
Dimensions (LxWxH) ............................. 327 x 312 x 207 mm (12.8 x 12.3 x 8.1
in.)
Weight .................................................... 4 kg (8.8 lbs.)
DYNAMIC EFFECTS
Dimming ................................................ 0 – 100%, coarse & fine control
Shutter ................................................... Strobe & pulse effects, instant open
and blackout
CONTROL AND PROGRAMMING
Control system ...................................... USITT DMX512/1990 with RDM
DMX channels ........................................ 3
RDM compliance .................................... ANSI/ESTA E.120
Interface ................................................. Control panel with backlit LCD display
CONSTRUCTION
Color....................................................... Black
Housing .................................................. Cast aluminum
IP rating ................................................. IP 20
INSTALLATION
Mounting points ..................................... Adjustable bracket, surface or
truss mount
Location ................................................. Indoor location only
Orientation ............................................. Any
Minimum distance to
illuminated surfaces ............................. 0.5 m (20 in.)
Minimum distance to
combustible materials .......................... 0.1 m (4 in.)
TYPICAL POWER AND CURRENT
100 V, 60 Hz ............................................ 114 W, 1.2 A, PF 1.000
120 V, 60 Hz ............................................ 114 W, 1.0 A, PF 0.996
230 V, 50 Hz ............................................ 114 W, 0.5 A, PF 0.933
Measurements made at nominal voltage. Figures are typical, not maximum, allow for a deviation of +/- 10%.
THERMAL
Cooling ................................................... Forced air, temperature-regulated
Maximum ambient
temperature (Ta max.)........................... 40° C (104° F)
Minimum ambient
temperature (Ta min) ............................ 0°C (32° F)
APPROVALS
EU safety ................................................ EN 60598-2-17 (EN 60598-1), EN 62471,
EN 62493
EU EMC .................................................. EN 55015; EN 55032; EN 55103-1,-2;
EN 61000-3-2,-3; EN 61000-4-2, -4, -5; EN 61547
US safety ................................................ UL 1573
US EMC ..................................................47 CFR 15 Class A
Canadian safety .....................................CSA C22.2 No. 166
Canadian EMC ........................................ ICES-003 Class A
Australia/NZ ..........................................RCM (Pending)
CONNECTIONS
AC power input/output .......................... Neutrik PowerCon
DMX & RDM data in/out ......................... 5-pin locking XLR
ELECTRICAL
AC power ................................................ 100-240 V nominal, 50/60 Hz
Power supply unit .................................. Auto-ranging electronic switch mode
Maximum total power consumption ..... 114 W
Typical half-cycle RMS inrush current . 11.2 A Recommended Miniature Circuit
Breaker when power linking* ............... Type D
*Per IEC 60898/UL489/CSA C22.2 No. 5